文献速递泌尿生殖腹部MR

基于多参数MRI的机器学习模型与2019版Bosniak分类鉴别囊性肾肿物的多中心研究

Multiparametric MRI-Based Machine Learning Models for the Characterization of Cystic Renal Masses Compared to the Bosniak Classification, Version 2019: A Multicenter Study.
PubMed 文献 · Acad Radiol · 2024-01-19

多中心研究纳入2009至2021年经手术病理证实的囊性肾肿物患者,构建基于多参数MRI的机器学习模型鉴别良恶性,并与2019版Bosniak分类比较。测试集中随机森林模型AUC 0.907、准确率83.3%,与Bosniak分类(AUC 0.893、准确率81.2%)差异无统计学意义;在复杂囊性肾肿物中随机森林模型AUC 0.880、准确率81.0%。

要点

  • 随机森林模型鉴别良恶性囊性肾肿物AUC 0.907、准确率83.3%,与2019版Bosniak分类性能相当。
  • 复杂囊性肾肿物(II-IV类)中随机森林模型AUC 0.880、准确率81.0%。
  • 模型与Bosniak分类AUC比较P=0.780、准确率比较P=0.065,均无显著差异。

核心结论

  • 基于MRI的随机森林模型能准确鉴别良恶性囊性肾肿物,性能与2019版Bosniak分类相当,在复杂囊性肾肿物中表现良好,可能有助于治疗决策且受观察者间分歧影响较小。

研究设计与样本

  • 多中心研究,纳入2009至2021年经手术病理证实的囊性肾肿物患者,训练集278例、测试集48例;构建逻辑回归、随机森林和支持向量机三种模型,由两名放射科医师按2019版Bosniak分类在测试集中共识分类。

诊断标准与关键数值

  • 测试集中逻辑回归模型AUC 0.884、准确率75.0%;随机森林模型AUC 0.907、准确率83.3%;支持向量机模型AUC 0.814、准确率72.9%;2019版Bosniak分类AUC 0.893、准确率81.2%。

临床应用与阅片要点

  • 作者认为MRI随机森林模型与2019版Bosniak分类性能相当,可能有助于治疗决策,且受观察者间分歧影响较小。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVE: Accurate differentiation between benign and malignant cystic renal masses (CRMs) is challenging in clinical practice. This study aimed to develop MRI-based machine learning models for differentiating between benign and malignant CRMs and compare the best-performing model with the Bosniak classification, version 2019 (BC, version 2019).

METHODS: Between 2009 and 2021, consecutive surgery-proven CRM patients with renal MRI were enrolled in this multicenter study. Models were constructed to differentiate between benign and malignant CRMs using logistic regression (LR), random forest (RF), and support vector machine (SVM) algorithms, respectively. Meanwhile, two radiologists classified CRMs into I-IV categories according to the BC, version 2019 in consensus in the test set. A subgroup analysis was conducted to investigate the performance of the best-performing model in complicated CRMs (II-IV lesions in the test set). The performances of models and BC, version 2019 were evaluated using the area under the receiver operating characteristic curve (AUC). Performance was statistically compared between the best-performing model and the BC, version 2019.

RESULTS: 278 and 48 patients were assigned to the training and test sets, respectively. In the test set, the AUC and accuracy of the LR model, the RF model, the SVM model, and the BC, version 2019 were 0.884 and 75.0%, 0.907 and 83.3%, 0.814 and 72.9%, and 0.893 and 81.2%, respectively. Neither the AUC nor the accuracy of the RF model that performed best were significantly different from the BC, version 2019 (P = 0.780, P = 0.065). The RF model achieved an AUC and accuracy of 0.880 and 81.0% in complicated CRMs.

CONCLUSIONS: The MRI-based RF model can accurately differentiate between benign and malignant CRMs with comparable performance to the BC, version 2019, and has good performance in complicated CRMs, which may facilitate treatment decision-making and is less affected by interobserver disagreements.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Kang H, Xie W, Wang H, et al. Multiparametric MRI-Based Machine Learning Models for the Characterization of Cystic Renal Masses Compared to the Bosniak Classification, Version 2019: A Multicenter Study. Acad Radiol. 2024. PMID: 38242731. doi:10.1016/j.acra.2024.01.003

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。