博斯尼亚克3级和4级囊性肾病变分类应用超声造影的预测效能
本研究为单中心回顾性研究,评估2019至2022年间使用SonoVue行肾脏超声造影并诊断为博斯尼亚克3级或4级病变的49例患者共50个病灶,其中31个病灶有组织病理学结果。博斯尼亚克3级与4级对肿瘤性病变的阳性预测值相当(75% vs 93.3%,P = .33),但对恶性病变的阳性预测值在4级组显著更高(25% vs 93.33%,P = .0002)。结论认为超声造影对博斯尼亚克4级病变的恶性预测效能高,而3级组因良性病变比例大该效能未能维持。
要点
- 博斯尼亚克4级病变对恶性肿瘤的阳性预测值为93.33%,3级仅为25%(P = .0002)。
- 以薄分隔 vivid 强化为主要超声造影特征的病灶均非恶性。
- 博斯尼亚克3级中的主要良性病变包括嗜酸细胞瘤、低度恶性潜能多房囊性肾肿瘤和囊性肾瘤。
核心结论
- 超声造影对博斯尼亚克4级病变的恶性预测效能高,但该效能未能在博斯尼亚克3级组维持,因该组良性病变占较大比例。
研究设计与样本
- 单中心回顾性研究,纳入2019至2022年间使用SonoVue行肾脏超声造影并诊断为博斯尼亚克3级或4级病变的49例患者共50个病灶,其中31个病灶有组织病理学结果,以组织病理学诊断为参考标准。
关键影像表现/征象
- 以薄分隔 vivid 强化为主要超声造影特征的病灶均非恶性。
- 博斯尼亚克3级病变中的主要良性实体包括嗜酸细胞瘤、低度恶性潜能多房囊性肾肿瘤和囊性肾瘤。
- 导致假阳性影像学表现的主要模仿病变为局限性囊性肾病和出血性囊肿。
诊断标准与关键数值
- 博斯尼亚克3级对肿瘤性病变的阳性预测值为75%,博斯尼亚克4级为93.3%(P = .33)。
- 博斯尼亚克3级对组织病理学恶性病变的阳性预测值为25%,博斯尼亚克4级为93.33%(P = .0002)。
临床应用与阅片要点
- 对于超声造影评估为博斯尼亚克3级的可疑病变,作者认为需考虑遵循严格的纳入标准和主动监测策略。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Contrast-enhanced ultrasound (CEUS) is increasingly utilized for the noninvasive assessment of renal cystic lesions, using the Bosniak grading system. Bosniak 3-4 lesions require surgical referral, which allows correlation with the histopathological outcome.
METHODS: In this single-center, retrospective study we evaluated renal CEUS exams conducted with SonoVue® with a diagnosis of a Bosniak 3 or 4 lesion between 2019 and 2022. A total of 49 patients and 50 lesions met the inclusion criteria, 31 lesions had available histopathological results. Patient demographics, cyst morphology, and dominant imaging features were registered. The histopathological diagnosis was considered a reference standard.
RESULTS: Positive predictive power (PPV) for neoplastic lesions was comparable in the Bosniak 3 and 4 categories (75 vs 93.3%, P = .33), while PPV for histopathologically malignant lesion was considerably higher in the latter group (25 vs 93.33%, P = .0002). None of the lesions which had vividly enhancing thin septa as their dominant CEUS feature were malignant. Oncocytoma, multilocular cystic renal neoplasm of low malignant potential, and cystic nephroma were the major benign entities among Bosniak 3 lesions. Localized cystic kidney disease and hemorrhagic cysts were found to be the primary mimickers leading to false positive imaging findings.
CONCLUSIONS: CEUS has a high predictive power for malignancy in the Bosniak 4 category, which is not maintained in the Bosniak 3 group due to the large proportion of benign lesions. Adherence to rigorous rule-in criteria and active surveillance strategies need to be considered for equivocal CEUS Bosniak 3 lesions.
引用
- Járay Á, Farkas PI, Semjén D, et al. The Predictive Power of Bosniak 3 and 4 Cystic Renal Lesion Categorization Using Contrast-Enhanced Ultrasound. J Ultrasound Med. 2024. PMID: 38284141. doi:10.1002/jum.16424
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。