文献速递腹部CT

低对比剂用量与低管电压结合深度学习重建在肝脏CT中的应用

Deep-learning reconstruction with low-contrast media and low-kilovoltage peak for CT of the liver.
PubMed 文献 · Clin Radiol · 2024-01-06

该回顾性研究纳入70例肝病患者的CT三期动态增强图像,比较低对比剂用量(300 mg碘/kg)、80 kVp扫描结合深度学习重建(DLR)方案与常规对比剂用量(600 mg碘/kg)、120 kVp扫描结合混合迭代重建(HBIR)方案的图像质量和辐射剂量。结果显示DLR方案在多数指标上图像质量更优,且辐射剂量显著更低(p<0.01,最大降幅52%)。

要点

  • DLR方案(80 kVp、300 mg碘/kg)较HBIR方案(120 kVp、600 mg碘/kg)在门静脉期血管显示、图像噪声及肝实质强化方面视觉评分更优。
  • DLR方案在动脉期除肝实质外,CNR、SNR及FOM均显著优于HBIR方案。
  • DLR方案CTDIvol和SSDE均显著低于HBIR方案(p<0.01,最大降幅52%)。

核心结论

  • 采用低对比剂用量和低管电压的DLR协议较常规HBIR协议具有更好的图像质量和更低的辐射剂量。

研究设计与样本

  • 回顾性分析,纳入2020年4月至2022年3月大分大学医院70例肝病患者的CT三期动态增强图像,其中39例采用DLR协议(80 kVp、对比剂300 mg碘/kg),31例采用HBIR协议(120 kVp、对比剂600 mg碘/kg)。

关键影像表现/征象

  • DLR协议在门静脉血管可视化、图像噪声及肝实质对比增强方面的视觉评估值更优。
  • DLR协议在动脉期除肝实质外,CNR、SNR和FOM均显著优于HBIR协议。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To compare images using reduced CM, low-kVp scanning and DLR reconstruction with conventional images (no CM reduction, normal tube voltage, reconstructed with HBIR. To compare images using reduced contrast media (CM), low kilovoltage peak (kVp) scanning and deep-learning reconstruction (DLR) with conventional image quality (no CM reduction, normal tube voltage, reconstructed with hybrid-type iterative reconstruction method [HBIR protocol]).

MATERIALS AND METHODS: A retrospective analysis was performed on 70 patients with liver disease and three-phase dynamic imaging using computed tomography (CT) from April 2020 to March 2022 at Oita University Hospital. Of these cases, 39 were reconstructed using the DLR protocol at a tube voltage of 80 kVp and CM of 300 mg iodine/kg while 31 were imaged at a tube voltage of 120 kVp with CM of 600 mg iodine/kg and were reconstructed by the usual HBIR protocol. Images from the DLR and HBIR protocols were analysed and compared based on the contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR), figure-of-merit (FOM), and visual assessment. The CT dose index (CTDI)vol and size-specific dose estimates (SSDE) were compared with respect to radiation dose.

RESULTS: The DLR protocol was superior, with significant differences in CNR, SNR, and FOM except hepatic parenchyma in the arterial phase. For visual assessment, the DLR protocol had better values for vascular visualisation for the portal vein, image noise, and contrast enhancement of the hepatic parenchyma. Regarding comparison of the radiation dose, the DLR protocol was superior for all values of CTDIvol and SSDE, with significant differences (p<0.01; max. 52%).

CONCLUSION: Protocols using DLR with reduced CM and low kVp have better image quality and lower radiation dose compared to protocols using conventional HBIR.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Tachibana Y, Takaji R, Shiroo T, et al. Deep-learning reconstruction with low-contrast media and low-kilovoltage peak for CT of the liver. Clin Radiol. 2024. PMID: 38238148. doi:10.1016/j.crad.2023.12.015

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。