基于体积的18F-FDG PET/CT预测腹腔内硬纤维瘤主动监测的预后与结局
研究纳入18例腹腔内硬纤维瘤患者,测量MTV、TLG和SUVmax,分析其与主动监测结局及临床病理数据的关系。复发组MTV和TLG显著高于非复发组,MTV和TLG的截断值可区分复发与非复发、进展与稳定,并与无进展生存期显著相关。结论认为基于体积的18F-FDG PET可预测腹腔内硬纤维瘤主动监测的结局。
要点
- 复发组MTV和TLG显著高于非复发组(P<0.001和P=0.00)。
- 区分复发与非复发的MTV截断值760.8(敏感度1,特异度0.857,AUC=0.929)。
- 区分进展与稳定的MTV截断值197.1(敏感度0.9,特异度1,AUC=0.900)。
核心结论
- 基于体积的18F-FDG PET可预测腹腔内硬纤维瘤的预后,MTV和TLG可预测主动监测的结局,并可能作为手术风险和难度的预测指标。
研究设计与样本
- 研究纳入18例腹腔内硬纤维瘤患者,测量MTV、TLG和SUVmax,分析其与主动监测结局及临床、预后和病理数据的关系。
诊断标准与关键数值
- 区分复发与非复发:MTV截断值760.8,敏感度1,特异度0.857,AUC=0.929;TLG截断值1318.4,敏感度1,特异度0.786,AUC=0.911。
- 区分后续进展与稳定:MTV截断值197.1,敏感度0.9,特异度1,AUC=0.900;TLG截断值445.45,敏感度0.9,特异度1,AUC=0.900。
- MTV和TLG截断值与PFS显著相关(P=0.002和P=0.007)。
- MTV和TLG可区分后续进展与稳定的硬纤维瘤(P=0.004和P=0.004)。
临床应用与阅片要点
- 基于体积的18F-FDG PET指标MTV和TLG可用于预测腹腔内硬纤维瘤主动监测的结局。
- MTV和TLG可能作为手术风险和难度的预测指标。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Desmoid tumor (DT) is a rare monoclonal, fibroblastic proliferation characterized by a variable and often unpredictable clinical course. Initial active surveillance is recommended by current guideline, and surgery is one of the main therapies for DT. Predicting the prognosis and outcome of active surveillance for intra-abdominal DT is pressing issue.
METHODS: The study included eighteen patients with intra-abdominal DT. Metabolic tumor volume (MTV), total lesion glycolysis (TLG), and maximum standardized uptake value (SUVmax) were measured. We analyzed their relationship with the outcome of active surveillance, as well as clinical, prognostic, and pathological data.
RESULTS: The MTV and TLG of recurrent DT were significantly higher than those of non-recurrent DT (P < 0.001 and P = 0.00, respectively). The ROC curve suggested that the appropriate cutoff values for distinguishing recurrent DT from non-recurrent DT were 760.8 for MTV (sensitivity = 1, specificity = 0.857 and AUC = 0.929), and 1318.4 for TLG (sensitivity = 1, specificity = 0.786, and AUC = 0.911). The cutoff values of MTV and TLG significantly correlated with PFS using the Kaplan-Meier method (P = 0.002 and P = 0.007, respectively). MTV and TLG could distinguish DTs with subsequent progression from stable ones (P = 0.004 and P = 0.004, respectively). The ROC curve suggested that the appropriate cutoff values for distinguishing DTs with subsequent progression from stable ones were 197.1 for MTV (sensitivity = 0.9, specificity = 1, and AUC = 0.900), and 445.45 for TLG (sensitivity = 0.9, specificity = 1, and AUC = 0.900).
CONCLUSION: Volume-based 18F-FDG-PET can predict prognosis of intra-abdominal DT. MTV and TLG can predict the outcome of active surveillance for intra-abdominal DT. MTV and TLG can potentially be predictors of surgical risk and difficulty.
引用
- Liu DN, Li CP, Li HW, et al. Volume-based 18F-FDG PET/CT predicts prognosis and outcome of active surveillance for intra-abdominal desmoid tumor. Abdom Radiol (NY). 2024. PMID: 38245900. doi:10.1007/s00261-023-04145-z
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。