文献速递腹部MR

弥散加权成像中b值组合在鉴别肝纤维化中的比较与优化

Comparison and optimization of b value combinations for diffusion-weighted imaging in discriminating hepatic fibrosis.
PubMed 文献 · Abdom Radiol (NY) · 2024-01-29

前瞻性研究纳入81例慢性肝病患者和21名健康志愿者,行DWI、MR弹性成像和肝活检,计算九种b值二十种组合的ADC值。健康志愿者ADC值均显著高于肝纤维化组(均P<0.01),b值200与800 s/mm2及200与1000 s/mm2组合的ADC值对肝纤维化分期鉴别力更优,ADC200-1000与MRE剪切硬度呈 excellent 负相关(r=-0.750,P<0.001)。作者推荐临床评估肝纤维化时采用b值200-800 s/mm2至200-1000 s/mm2的ADC值。

要点

  • 健康志愿者ADC值均显著高于肝纤维化组(均P<0.01)。
  • b值200与800 s/mm2及200与1000 s/mm2组合的ADC值对肝纤维化分期鉴别力更优。
  • ADC200-1000与MRE剪切硬度呈 excellent 负相关(r=-0.750,P<0.001)。

核心结论

  • DWI可作为MRE的替代影像标志物用于检测和分期肝纤维化,临床推荐b值200-800 s/mm2至200-1000 s/mm2的ADC值评估肝纤维化。

研究设计与样本

  • 前瞻性研究纳入81例慢性肝病患者和21名健康志愿者,行DWI、MR弹性成像(MRE)和肝活检,以二十种b值组合(九种b值:0、50、100、150、200、800、1000、1200、1500 s/mm2)计算ADC。

诊断标准与关键数值

  • 健康志愿者所有ADC值均显著高于肝纤维化组(均P<0.01)。
  • 随肝纤维化进展,b值组合100与1000 s/mm2、150与1200 s/mm2、200与800 s/mm2、200与1000 s/mm2的ADC值显著降低。
  • b值200与800 s/mm2及200与1000 s/mm2组合的ADC值对肝纤维化分期鉴别力更优。
  • ADC200-1000与MRE剪切硬度呈 excellent 负相关(r=-0.750,P<0.001)。

临床应用与阅片要点

  • 作者推荐临床评估肝纤维化时采用b值200-800 s/mm2至200-1000 s/mm2的ADC值。
  • DWI可作为MRE的替代影像标志物用于检测和分期肝纤维化。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

INTRODUCTION AND OBJECTIVES: Diffusion-weighted imaging (DWI) has shown potential in characterizing hepatic fibrosis. However, there are no widely accepted apparent diffusion coefficient (ADC) values for the b value combination. This study aims to determine the optimal high and low b values of DWI to assess hepatic fibrosis in patients with chronic liver disease.

MATERIALS AND METHODS: The prospective study included 81 patients with chronic liver disease and 21 healthy volunteers who underwent DWI, Magnetic resonance elastography (MRE), and liver biopsy. The ADC was calculated by twenty combinations of nine b values (0, 50, 100, 150, 200, 800, 1000, 1200, and 1500 s/mm2).

RESULTS: All ADC values of the healthy volunteers were significantly higher than those of the hepatic fibrosis group (all P < 0.01). With the progression of hepatic fibrosis, ADC values significantly decreased in b value combinations (100 and 1000 s/mm2, 150 and 1200 s/mm2, 200 and 800 s/mm2, and 200 and 1000 s/mm2). ADC values derived from b values of both 200 and 800 s/mm2 and 200 and 1000 s/mm2 were found to be more discriminative for differentiating the stages of hepatic fibrosis. An excellent correlation was between the ADC200-1000 value and MRE shear stiffness (r = - 0.750, P < 0.001).

CONCLUSION: DWI offers an alternative to MRE as a useful imaging marker for detecting and staging hepatic fibrosis. Clinically, ADC values for b values ranging from 200-800 s/mm2 to 200-1000 s/mm2 are recommended for the assessment of hepatic fibrosis.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Wang J, Zhou X, Yao M, et al. Comparison and optimization of b value combinations for diffusion-weighted imaging in discriminating hepatic fibrosis. Abdom Radiol (NY). 2024. PMID: 38285179. doi:10.1007/s00261-023-04159-7

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。