人工智能迭代重建在结直肠癌诊断性CT中的临床评价
该回顾性研究纳入217例病理确诊的结直肠癌患者,比较人工智能迭代重建(AIIR)与混合迭代重建(HIR)的CT图像质量与诊断性能。AIIR在客观和主观图像质量上多数优于HIR,诊断脏器腹膜侵犯的AUC更高(0.87 vs 0.77,p=0.001),并能纠正肝转移误诊、提高诊断信心(p=0.01)。
要点
- AIIR图像的信噪比和对比噪声比均显著高于HIR(均p<0.001)。
- 诊断脏器腹膜侵犯时,AIIR的AUC为0.87,高于HIR的0.77(p=0.001)。
- AIIR可纠正HIR对肝转移的误诊并提高诊断信心(p=0.01)。
核心结论
- 与HIR相比,AIIR图像质量更好,能提高结直肠癌的诊断性能,因此有潜力用于常规腹部CT。
研究设计与样本
- 回顾性研究,纳入217例病理确诊的结直肠癌患者,其中116例有手术病理;CT图像分别用AIIR算法重建并与原HIR图像比较。
诊断标准与关键数值
- AIIR图像的信噪比和对比噪声比均显著高于HIR图像(均p<0.001)。
- 除区域淋巴结转移诊断确定性(p=0.467)外,AIIR在所有主观指标上评分均高于HIR(均p<0.001)。
- 诊断脏器腹膜侵犯时,AIIR的ROC曲线下面积高于HIR(0.87 vs 0.77,p=0.001)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To investigate the clinical value of a novel deep-learning based CT reconstruction algorithm, artificial intelligence iterative reconstruction (AIIR), in diagnostic imaging of colorectal cancer (CRC).
METHODS: This study retrospectively enrolled 217 patients with pathologically confirmed CRC. CT images were reconstructed with the AIIR algorithm and compared with those originally obtained with hybrid iterative reconstruction (HIR). Objective image quality was evaluated in terms of the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Subjective image quality was graded on the conspicuity of tumor margin and enhancement pattern as well as the certainty in diagnosing organ invasion and regional lymphadenopathy. In patients with surgical pathology (n = 116), the performance of diagnosing visceral peritoneum invasion was characterized using receiver operating characteristic (ROC) analysis. Changes of diagnostic thinking in diagnosing hepatic metastases were assessed through lesion classification confidence.
RESULTS: The SNRs and CNRs on AIIR images were significantly higher than those on HIR images (all p < 0.001). The AIIR was scored higher for all subjective metrics (all p < 0.001) except for the certainty of diagnosing regional lymphadenopathy (p = 0.467). In diagnosing visceral peritoneum invasion, higher area under curve (AUC) of the ROC was found for AIIR than HIR (0.87 vs 0.77, p = 0.001). In assessing hepatic metastases, AIIR was found capable of correcting the misdiagnosis and improving the diagnostic confidence provided by HIR (p = 0.01).
CONCLUSIONS: Compared to HIR, AIIR offers better image quality, improves the diagnostic performance regarding CRC, and thus has the potential for application in routine abdominal CT.
引用
- Li J, Zhu J, Zou Y, et al. Diagnostic CT of colorectal cancer with artificial intelligence iterative reconstruction: A clinical evaluation. Eur J Radiol. 2024. PMID: 38237522. doi:10.1016/j.ejrad.2024.111301
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。