文献速递腹部泌尿生殖技术与安全PETCT

肛周瘘管在PET/CT上的18F-氟脱氧葡萄糖摄取定量:一项回顾性分析

Quantifying 18F-Fluorodeoxyglucose Uptake in Perianal Fistulas on PET/CT: A Retrospective Analysis.
PubMed 文献 · Acad Radiol · 2024-01-03

该回顾性研究纳入24例可识别肛周瘘管的患者,分析PET/CT上瘘管、脓肿、肛管、直肠和肝脏的SUVmax。瘘管SUVmax均值10.8±5.28,显著高于肝脏(3.09±0.584,p<0.0001)和肛管(5.98±2.63,p=0.0005)。St. James 1级瘘管SUVmax显著低于2级和4级(p=0.0224和p=0.0295)。

要点

  • 肛周瘘管FDG摄取高,SUVmax均值10.8±5.28,显著高于肛管和肝脏。
  • 脓肿瘘管SUVmax为15.8±4.91,提示合并脓肿时摄取更高。
  • St. James 1级瘘管SUVmax显著低于2级和4级。

核心结论

  • 肛周瘘管FDG摄取增高,瘘管SUVmax显著高于肛管。

研究设计与样本

  • 回顾性分析,纳入2011年1月至2023年5月期间因血液/肿瘤诊断或分期行FDG-PET/CT且报告描述肛周瘘管或脓肿的患者24例,记录瘘管、脓肿、肛管、直肠和肝脏的SUVmax。

诊断标准与关键数值

  • 瘘管SUVmax均值10.8±5.28,肝脏均值3.09±0.584,肛管均值5.98±2.63。
  • 脓肿瘘管SUVmax为15.8±4.91。
  • St. James 1级瘘管SUVmax显著低于2级(p=0.0224)和4级(p=0.0295)。
  • 肛肠癌组与非肛肠癌组间SUVmax比值无显著差异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: The use of 18F-fluorodeoxyglucose positron emission tomography-computed tomography (FDG-PET/CT) in assessing inflammatory diseases has shown significant promise. Uptake patterns in perianal fistulas, which may be an incidental finding on PET/CT, have not been purposefully studied. Our aim was to compare FDG uptake of perianal fistulas to that of the liver and anal canal in patients who underwent PET/CT for hematologic/oncologic diagnosis or staging.

MATERIALS AND METHODS: We retrospectively identified patients who underwent FDG-PET/CT imaging between January 2011 and May 2023, where the report described a perianal fistula or abscess. PET/CTs of patients included in the study were retrospectively analyzed to record the maximum standardized uptake value (SUVmax) of the fistula, abscess, anal canal, rectum, and liver. Fistula-to-liver and Fistula-to-anus SUVmax ratios were calculated. We statistically compared FDG activity among the fistula, liver, and anal canal. We also assessed FDG activity in patients with vs. without anorectal cancer, as well as across different St. James fistula grades.

RESULTS: The study included 24 patients with identifiable fistulas. Fistula SUVmax (mean=10.8 ± 5.28) was significantly higher than both the liver (mean=3.09 ± 0.584, p < 0.0001) and the anal canal (mean=5.98 ± 2.63, p = 0.0005). Abscess fistula SUVmax was 15.8 ± 4.91. St. James grade 1 fistulas had significantly lower SUVmax compared to grades 2 and 4 (p = 0.0224 and p = 0.0295, respectively). No significant differences existed in SUVmax ratios between anorectal and non-anorectal cancer groups.

CONCLUSION: Perianal fistulas have increased FDG avidity with fistula SUVmax values that are significantly higher than the anal canal.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Huang K, Garuba F, Ganapathy A, et al. Quantifying 18F-Fluorodeoxyglucose Uptake in Perianal Fistulas on PET/CT: A Retrospective Analysis. Acad Radiol. 2024. PMID: 38177032. doi:10.1016/j.acra.2023.12.020

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。