心血管磁共振与超声心动图评估儿童法洛四联症根治术后右心室舒张功能
纳入130例儿童法洛四联症根治术后患者及43名对照,比较心血管磁共振与超声心动图测量的右心室舒张参数,两者一致性良好(ICC 0.70-0.89)。磁共振来源的E/e'是右心室舒张功能障碍的独立预测因子,以5.8为界值鉴别诊断效能最高(AUC 0.76,敏感度70%,特异度86%)。
要点
- 磁共振相位对比与特征追踪可测量右心室舒张参数,与超声心动图一致性良好(ICC 0.70-0.89)。
- 儿童法洛四联症根治术后右心室舒张功能障碍患病率超过半数(67/130)。
- 磁共振E/e'=5.8时鉴别右心室舒张功能障碍的AUC为0.76,敏感度70%,特异度86%。
核心结论
- 心血管磁共振来源的舒张参数与超声心动图一致性良好,其中E/e'鉴别右心室舒张功能障碍最有效,磁共振可作为超声心动图评估右心室舒张功能的可靠补充手段。
研究设计与样本
- 研究纳入130例连续儿童法洛四联症根治术后患者(均接受临床指征的心血管磁共振及同日超声心动图)和43名对照,采用相位对比成像测量三尖瓣血流速度,特征追踪测量三尖瓣环心肌速度,以超声心动图为参照评估右心室舒张功能。
关键影像表现/征象
- 磁共振与超声心动图测量的右心室舒张参数一致性良好,ICC为0.70-0.89。
- 右心室舒张功能障碍患者(n=67)与无功能障碍患者(n=63)相比,磁共振来源的E速度、e'速度、E/A比值及E/e'比值均有显著差异(均p<0.05)。
诊断标准与关键数值
- 磁共振来源的E速度、e'速度和E/e'比值是右心室舒张功能障碍的独立预测因子。
- E/e'=5.8时鉴别右心室舒张功能障碍的AUC为0.76,敏感度70%,特异度86%。
临床应用与阅片要点
- 利用常规采集的电影序列和相位对比磁共振图像即可获得右心室舒张参数,无需额外序列。
- 磁共振测量的E/e'可用于鉴别儿童法洛四联症根治术后右心室舒张功能障碍,与超声心动图结果互为补充。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Cardiovascular magnetic resonance (CMR) imaging is routinely performed for assessing right ventricular (RV) systolic but not diastolic function. We aimed to investigate CMR-based assessment of RV diastolic function in pediatric patients with repaired tetralogy of Fallot (rTOF), compared to transthoracic echocardiography (TTE) measurements.
METHODS: A total of 130 consecutive pediatric patients with rTOF who underwent clinically indicated CMR and same-day TTE were included. Forty-three controls were recruited. Phase-contrast images were used to measure trans-tricuspid valve flow velocities during early (E) and late diastolic (A) phases (measured in cm/s). Feature tracking of the tricuspid annulus was performed to derive early (e') and late diastolic (a') myocardial velocities (measured in cm/s). RV diastolic function was evaluated by E/A ratio, E/e' ratio, and E-wave deceleration time (measured in milliseconds). Regression analyses were utilized to identify potential variables associated with RV diastolic dysfunction (DD). The performance of CMR-derived parameters in diagnosing RV DD was assessed using receiver-operating characteristic analyses.
RESULTS: Good agreement was found between CMR and TTE measurements (ICC 0.70-0.89). Patients with RV DD (n = 67) showed significantly different CMR-derived parameters including E and e' velocities, and E/A and E/e' ratio, compared to patients without DD (n = 63) (all p < 0.05). CMR-derived E and e' velocities and E/e' ratio were independent predictors of RV DD. E/e' of 5.8 demonstrated the highest discrimination of RV DD (AUC 0.76, sensitivity 70%, specificity 86%).
CONCLUSIONS: CMR-derived parameters showed good agreement with TTE parameters in determining RV DD. CMR-derived E/e' was proved to be the most effective in identifying RV DD.
CLINICAL RELEVANCE STATEMENT: This study demonstrated the feasibility and efficacy of CMR in assessing diastolic function in pediatric patients. RV DD was presented in over half of patients according to current TTE guidelines, highlighting the need for assessing RV diastolic function during follow-up.
KEY POINTS: • Routinely acquired cine and phase-contrast cardiovascular magnetic resonance (CMR) images yielded right ventricular (RV) diastolic parameters which demonstrated good agreement with transthoracic echocardiography (TTE) measurements. • There was a high prevalence of RV diastolic function impairment in pediatric patients with repaired tetralogy of Fallot (rTOF). • CMR is a reliable complementary modality of TTE for RV diastolic function evaluation.
引用
- Ouyang R, Leng S, Chen L, et al. Assessment of right ventricular diastolic function in pediatric patients with repaired tetralogy of Fallot by cardiovascular magnetic resonance and echocardiography. Eur Radiol. 2024. PMID: 38180528. doi:10.1007/s00330-023-10538-x
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。