高帧率向量血流成像评估动脉粥样硬化性颈动脉狭窄的湍流指数与血流模式
本研究前瞻性纳入60例动脉粥样硬化性颈内动脉狭窄患者,用高帧率向量血流成像定量分析湍流指数并描绘复杂血流模式。结果显示狭窄段与远端段湍流明显增高,湍流分级与狭窄率及溃疡形成相关,重度狭窄组和溃疡组三种血流模式检出率更高。
要点
- 狭窄段与远端段湍流指数明显增高,收缩期尤为突出。
- 湍流分级与狭窄率、溃疡形成相关,可辅助识别高危斑块。
- 重度狭窄组与溃疡组的复杂血流模式检出率更高。
核心结论
- 高帧率向量血流成像有助于评估血流湍流的严重程度与特征。
- 管腔几何因素可影响斑块周围的血流湍流与血流模式。
- 该技术可为高危斑块的检出提供重要血流动力学信息。
研究设计与样本
- 前瞻性研究,纳入60例动脉粥样硬化性颈内动脉狭窄患者。
- 采用高帧率向量血流成像测量湍流指数并定性描绘血流模式。
关键影像表现/征象
- 狭窄段湍流指数(M,QR)为12.5%、21.5%,远端段为15.4%、27.2%。
- 收缩期湍流尤为明显,湍流指数分别为21.0%、30.7%、33.3%、38.7%(p < 0.05)。
- 在向量血流模式下定性描绘出三种复杂血流模式。
诊断标准与关键数值
- 狭窄段湍流分级与狭窄率相关(ρ = 0.65,p < 0.05)。
- 远端段湍流分级与狭窄率相关(ρ = 0.79,p < 0.05)。
- 狭窄段湍流分级与溃疡形成相关(ρ = 0.58,p < 0.05)。
- 三种血流模式总检出率:重度狭窄组22/22 vs 轻中度狭窄组21/38(p < 0.001)。
- 三种血流模式总检出率:溃疡组21/23 vs 无溃疡组23/37(p < 0.001)。
临床应用与阅片要点
- 可利用高帧率向量血流成像观察狭窄段及远端段湍流,收缩期改变更明显。
- 湍流分级与狭窄率、溃疡形成相关,阅片时可结合斑块溃疡征象综合评估高危斑块。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: The emerging high-frame-rate vector flow imaging provides a new way of hemodynamic evaluation for complex blood flow. This study was aimed at exploring quantitatively the characteristics of complex flow with turbulence (Tur) index and analyzing flow patterns in atherosclerotic internal carotid artery stenosis (ICAS) using high-frame-rate vector flow imaging.
METHODS: This study prospectively included 60 patients with ICAS. Tur values in different segments of stenosis and cardiac phases were compared. Spearman correlation analysis was performed between clinical plaque characteristics with turbulence grading by ln(Tur). Three complex flow patterns were qualitatively drawn on vector flow mode, and the rates of detection of flow patterns in different stenosis groups and ulceration groups were compared.
RESULTS: Highly disordered blood flow was observed in the stenotic (Tur [M, QR] = 12.5%, 21.5%) and distal segment (15.4%, 27.2%), particularly during systole (21.0%, 30.7%, 33.3%, 38.7%, p < 0.05). Spearman correlation analysis revealed that stenosis rate was correlated with turbulence grading in the stenotic (ρ = 0.65, p < 0.05) and distal segment (ρ = 0.79, p < 0.05), and ulcer formation was correlated with turbulence grading in the stenotic segment (ρ = 0.58, p < 0.05). The overall rate of detection of three flow patterns was higher in the severe stenosis group (22/22) versus the mild to moderate stenosis group (21/38) (p < 0.001) and in the ulcer group (21/23) versus the non-ulcer group (23/37) (p < 0.001).
CONCLUSION: High-frame-rate vector flow imaging was helpful in assessing the severity and characteristics of flow turbulence. Lumen geometric factors could affect flow turbulence and blood flow patterns around the plaque. This would provide important hemodynamic information for the detection of high-risk plaque.
引用
- Dong Y, Gao W, Hong S, et al. Evaluation of Turbulence Index and Flow Pattern for Atherosclerotic Carotid Stenosis: A High-Frame-Rate Vector Flow Imaging Study. Ultrasound Med Biol. 2024. PMID: 38262885. doi:10.1016/j.ultrasmedbio.2023.12.019
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。