文献速递妇产影像儿科影像心血管US

产前超声诊断主动脉缩窄的诊断准确性:系统评价与个体参与者数据Meta分析

Diagnostic accuracy of prenatal ultrasound in coarctation of aorta: systematic review and individual participant data meta-analysis.
PubMed 文献 · Ultrasound Obstet Gynecol · 2024-03-09

该系统评价与个体参与者数据Meta分析纳入17项研究共640例胎儿,评估产前超声各参数与出生后主动脉缩窄的关联及诊断准确性。结果显示三尖瓣/二尖瓣直径比>1.4、肺动脉/升主动脉直径比>1.4、主动脉峡部Z值<-2及主动脉弓发育不良等参数与主动脉缩窄独立相关,但即使联合多个参数,诊断准确性仅为中等。

要点

  • 三尖瓣/二尖瓣直径比>1.4诊断主动脉缩窄的敏感度72.6%、特异度65.4%,DOR 5.02。
  • 主动脉弓发育不良诊断主动脉缩窄的敏感度70.0%、特异度91.3%,DOR 24.9。
  • 多个参数联合并未显著提高产前超声检出主动脉缩窄的诊断效能。

核心结论

  • 多种产前超声参数与出生后主动脉缩窄风险增加相关,但即使联合多个参数,诊断准确性仅为中等。

研究设计与样本

  • 个体参与者数据Meta分析,检索MEDLINE、EMBASE和CINAHL 2000年1月至2021年11月文献,最终纳入17项研究共640例胎儿,参考标准为出生后诊断的主动脉弓狭窄。

诊断标准与关键数值

  • 三尖瓣/二尖瓣直径比>1.4:敏感度72.6%(95%CI 48.2-88.3%),特异度65.4%(95%CI 46.9-80.2%),DOR 5.02(95%CI 1.82-13.9)。
  • 肺动脉/升主动脉直径比>1.4:敏感度75.0%(95%CI 61.1-86.0%),特异度39.7%(95%CI 27.0-53.4%)。
  • 矢状面主动脉峡部直径Z值<-2:敏感度47.8%(95%CI 14.6-83.0%),特异度87.6%(95%CI 27.3-99.3%)。
  • 三血管气管切面主动脉峡部直径Z值<-2:敏感度74.1%(95%CI 58.0-85.6%),特异度62.0%(95%CI 41.6-78.9%)。
  • 主动脉弓发育不良:敏感度70.0%(95%CI 42.0-88.6%),特异度91.3%(95%CI 78.6-96.8%),DOR 24.9(95%CI 6.18-100)。

临床应用与阅片要点

  • 随机效应logistic回归显示三尖瓣/二尖瓣直径比>1.4和>1.6、主动脉峡部/动脉导管直径比<0.7、主动脉弓发育不良(均P<0.001)与主动脉缩窄独立相关。
  • 矢状面(P=0.003)和三血管气管切面(P<0.001)主动脉峡部直径Z值<-2、肺动脉/升主动脉直径比>1.4(P=0.048)、卵圆孔双向血流(P=0.012)与主动脉缩窄独立相关。
  • 卵圆孔冗长与主动脉缩窄呈负相关(P=0.037)。
  • 11个评估的连续参数中有5个与主动脉缩窄独立相关(均P<0.001),但诊断效能均为低至中等。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To determine the diagnostic accuracy of prenatal ultrasound in detecting coarctation of the aorta (CoA).

METHODS: An individual participant data meta-analysis was performed to report on the strength of association and diagnostic accuracy of different ultrasound signs in detecting CoA prenatally. MEDLINE, EMBASE and CINAHL were searched for studies published between January 2000 and November 2021. Inclusion criteria were fetuses with suspected isolated CoA, defined as ventricular and/or great vessel disproportion with right dominance on ultrasound assessment. Individual participant-level data were obtained by two leading teams. PRISMA-IPD and PRISMA-DTA guidelines were used for extracting data, and the QUADAS-2 tool was used for assessing quality and applicability. The reference standard was CoA, defined as narrowing of the aortic arch, diagnosed after birth. The most commonly evaluated parameters on ultrasound, both in B-mode and on Doppler, constituted the index test. Summary estimates of sensitivity, specificity, diagnostic odds ratio (DOR) and likelihood ratios were computed using the hierarchical summary receiver-operating-characteristics model.

RESULTS: The initial search yielded 72 studies, of which 25 met the inclusion criteria. Seventeen studies (640 fetuses) were included. On random-effects logistic regression analysis, tricuspid valve/mitral valve diameter ratio > 1.4 and > 1.6, aortic isthmus/arterial duct diameter ratio < 0.7, hypoplastic aortic arch (all P < 0.001), aortic isthmus diameter Z-score of < -2 in the sagittal (P = 0.003) and three-vessel-and-trachea (P < 0.001) views, pulmonary artery/ascending aorta diameter ratio > 1.4 (P = 0.048) and bidirectional flow at the foramen ovale (P = 0.012) were independently associated with CoA. Redundant foramen ovale was inversely associated with CoA (P = 0.037). Regarding diagnostic accuracy, tricuspid valve/mitral valve diameter ratio > 1.4 had a sensitivity of 72.6% (95% CI, 48.2-88.3%), specificity of 65.4% (95% CI, 46.9-80.2%) and DOR of 5.02 (95% CI, 1.82-13.9). The sensitivity and specificity values were, respectively, 75.0% (95% CI, 61.1-86.0%) and 39.7% (95% CI, 27.0-53.4%) for pulmonary artery/ascending aorta diameter ratio > 1.4, 47.8% (95% CI, 14.6-83.0%) and 87.6% (95% CI, 27.3-99.3%) for aortic isthmus diameter Z-score of < -2 in the sagittal view and 74.1% (95% CI, 58.0-85.6%) and 62.0% (95% CI, 41.6-78.9%) for aortic isthmus diameter Z-score of < -2 in the three-vessel-and-trachea view. Hypoplastic aortic arch had a sensitivity of 70.0% (95% CI, 42.0-88.6%), specificity of 91.3% (95% CI, 78.6-96.8%) and DOR of 24.9 (95% CI, 6.18-100). The diagnostic yield of prenatal ultrasound in detecting CoA did not change significantly when considering multiple categorical parameters. Five of the 11 evaluated continuous parameters were independently associated with CoA (all P < 0.001) but all had low-to-moderate diagnostic yield.

CONCLUSIONS: Several prenatal ultrasound parameters are associated with an increased risk for postnatal CoA. However, diagnostic accuracy is only moderate, even when combinations of parameters are considered. © 2024 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Villalaín C, D'Antonio F, Flacco ME, et al. Diagnostic accuracy of prenatal ultrasound in coarctation of aorta: systematic review and individual participant data meta-analysis. Ultrasound Obstet Gynecol. 2024. PMID: 38197327. doi:10.1002/uog.27576

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。