多激发梯度回波平面成像序列在非增强自由呼吸全心磁共振冠状动脉血管成像中的可行性研究
本研究纳入29名健康志愿者,比较多激发梯度回波平面成像(MSG-EPI)序列与快速梯度回波(GRE)序列在非增强自由呼吸全心磁共振冠状动脉血管成像中的表现。结果显示MSG-EPI序列的左主干冠状动脉对比噪声比更高、部分冠状动脉节段主观质量评分更优、可评估长度更长,且扫描时间较快速GRE序列减少54.5%。
要点
- MSG-EPI序列左主干冠状动脉对比噪声比高于快速GRE序列(p=0.001)。
- MSG-EPI序列前降支中远段及回旋支远段主观质量评分优于快速GRE序列。
- MSG-EPI序列扫描时间较快速GRE序列减少54.5%(p<0.001)。
核心结论
- MSG-EPI序列可提高MRCA的主客观图像质量并缩短扫描时间。
研究设计与样本
- 可行性研究,纳入29名健康志愿者,采用自由呼吸全心MRCA采集,比较MSG-EPI序列与快速梯度回波(GRE)序列。
关键影像表现/征象
- MSG-EPI序列左主干冠状动脉对比噪声比高于快速GRE序列(p=0.001)。
- MSG-EPI序列前降支中段、前降支远段及回旋支远段主观质量评分均高于快速GRE序列(p=0.003、0.001、0.003)。
- MSG-EPI序列前降支和回旋支可评估长度均优于快速GRE序列(p=0.015和<0.001)。
- MSG-EPI序列与快速GRE序列左主干冠状动脉信噪比无显著差异(p=0.130)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To investigate the feasibility of non-enhanced and free-breathing whole-heart magnetic resonance coronary angiography (MRCA) using multishot gradient-echo planar imaging (MSG-EPI).
MATERIALS AND METHODS: In total, 29 healthy volunteers were recruited for free-breathing whole-heart MRCA acquisition using the MSG-EPI sequence and fast gradient echo (GRE) sequence. After the examination, the actual scanning times, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) of the left main (LM) coronary artery, subjective quality scores for each segment, and evaluable length of the coronary artery were recorded and statistically analysed.
RESULTS: There was no significant difference between the SNRLM of the MSG-EPI sequence and fast GRE sequence (p=0.130), but the CNRLM of the MSG-EPI sequence was higher (p=0.001). The subjective quality score of the mid- and distal left anterior descending branch as well as the distal circumflex branch of the coronary artery in the MSG-EPI sequence was higher than that in the fast GRE sequence (p=0.003, 0.001, and 0.003, respectively). The evaluable length of the left anterior descending branch and the circumflex branch was better using the MSG-EPI sequence than that of the fast GRE sequence (p=0.015 and < 0.001, respectively). Moreover, the scanning time of the MSG-EPI sequence was 54.5% less than that of the fast GRE sequence (p<0.001).
CONCLUSION: The MSG-EPI sequence improves the subjective and objective image quality of MRCA as well as reduces the scanning time.
引用
- Yu A, Gao H, Ma Y, et al. Feasibility study of the multishot gradient-echo planar imaging sequence in non-enhanced and free-breathing whole-heart magnetic resonance coronary angiography. Clin Radiol. 2023. PMID: 38160106. doi:10.1016/j.crad.2023.12.006
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。