心脏磁共振首过灌注成像半定量评估杜氏肌营养不良症患儿微血管功能障碍的新应用
本研究纳入67例杜氏肌营养不良症(DMD)患儿和15名对照,行对比增强心脏磁共振首过灌注及延迟钆增强(LGE)序列,分析整体、区域及冠状动脉分布区的灌注指数。结果显示LGE阳性组整体及心尖部最大信号强度低于对照组,LGE阴性组左前降支及左回旋支分布区部分灌注参数低于对照组,灌注参数与常规心功能及LGE范围相关。结论提示DMD患儿可能存在微血管功能障碍,且可能早于LGE出现。
要点
- DMD患儿LGE阳性组整体及心尖部MaxSI低于对照组,提示微血管功能障碍。
- LGE阴性组左前降支及左回旋支分布区部分灌注参数低于对照组,微血管障碍可能早于LGE。
- 灌注参数(upslope、MaxSI、TTM)与常规心功能及LGE范围相关。
核心结论
- DMD患儿可能存在微血管功能障碍,该障碍可能早于LGE出现,并与冠状动脉血供及LGE范围相关。
研究设计与样本
- 研究纳入67例DMD患儿和15名对照,均行对比增强CMR首过灌注及LGE序列,比较LGE阳性组、LGE阴性组与对照组的灌注参数。
关键影像表现/征象
- LGE阳性组整体及心尖部MaxSI低于对照组(均P < .05);LGE阳性组左前降支、左回旋支及右冠状动脉分布区upslope和MaxSI均低于对照组(均P < .05);LGE阴性组左前降支分布区MaxSI低于对照组(41.10 ± 11.08 vs 46.36 ± 13.04;P < .001),左回旋支分布区PI和upslope低于对照组(11.05 ± 2.84 vs 12.46 ± 2.82;P = .001;59.31 ± 26.76 vs 68.57 ± 29.99;P = .002)。
临床应用与阅片要点
- 作者指出首过灌注参数可揭示DMD患者心肌微循环状态并更早反映心肌损伤程度;灌注参数除按整体及基底、中间、心尖段分析外,还应按冠状动脉分布区分析,可能更早发现LGE阴性DMD患儿的微血管功能障碍。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The current study aimed to assess myocardial microcirculation dysfunction via cardiac magnetic resonance (CMR) first-pass perfusion imaging in children with Duchenne muscular dystrophy (DMD).
METHODS: In total, 67 children with DMD and 15 controls who underwent contrast-enhanced CMR first-pass perfusion imaging were enrolled in this study. CMR first-pass perfusion and late gadolinium enhancement (LGE) sequences were acquired. Further, the global, regional, and coronary artery distribution area perfusion indexes (PI), upslope (%BL), maximum signal intensity (MaxSI), time to maximum signal intensity (TTM), and baseline SI were analysed. The perfusion parameters of the LGE positive (+), LGE negative (-), and control groups were compared. Pearson correlation analysis was performed to assess the association between myocardial microcirculation and conventional cardiac function and LGE parameters.
RESULTS: The LGE+ group had a significantly lower global and apical-ventricular MaxSI than the control group (all P < .05). The left anterior descending arterial (LAD), left circumflex coronary arterial (LCX), and right coronary arterial (RCA) segments of the LGE+ group had a lower upslope and MaxSI than those of the control group (all P < .05). The LAD segments of the LGE- group had a lower MaxSI than those of the control group (41.10 ± 11.08 vs 46.36 ± 13.04; P < .001). The LCX segments of the LGE- group had a lower PI and upslope than those of the control group (11.05 ± 2.84 vs 12.46 ± 2.82; P = .001; 59.31 ± 26.76 vs 68.57 ± 29.99; P = .002). Based on the correlation analysis, the upslope, MaxSI, and TTM were correlated with conventional cardiac function and LGE extent.
CONCLUSIONS: Paediatric patients with DMD may present with microvascular dysfunction. This condition may appear before LGE and may be correlated with coronary artery blood supply and LGE extent.
ADVANCES IN KNOWLEDGE: First-pass perfusion parameters may reveal the status of myocardial microcirculation and reflect the degree of myocardial injury at an earlier time in DMD patients. Perfusion parameters should be analysed not only via global or base, middle, and apical segments but also according to coronary artery distribution area, which may detect myocardial microvascular dysfunction at an earlier stage, in DMD patients with LGE-.
引用
- Xie L, Cai X, Guo Y, et al. Novel implementation of cardiac magnetic resonance first-pass perfusion imaging for semi-quantitatively evaluating microvascular dysfunction in paediatric patients with Duchenne muscular dystrophy. Br J Radiol. 2024. PMID: 38263818. doi:10.1093/bjr/tqad016
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。