全自动人工智能冠状动脉CT血管成像图像处理:效率、诊断能力与风险分层
前瞻性随机对照纳入两家医院1801例CCTA受试者,分别采用全自动人工智能(FAAI)与半自动图像处理,比较工作流程效率、阻塞性冠心病诊断准确性和2年心血管事件风险分层,发现FAAI在诊断准确性和C指数方面非劣效于半自动模式,且图像处理和报告发布效率显著提高。
要点
- FAAI图像处理时间121.0 ± 18.6秒 vs 半自动433.5 ± 68.4秒,差异有统计学意义(p <0.001)。
- FAAI扫描至报告发布时间6.4 ± 2.7小时 vs 半自动10.5 ± 3.8小时,差异有统计学意义(p <0.001)。
- FAAI诊断阻塞性CAD准确率94.7%(89.9-97.7%)vs 半自动94.3%(89.5-97.4%),差值0.4%。
核心结论
- FAAI-based CCTA图像处理较半自动模式显著提升工作流程效率,在诊断阻塞性CAD和心血管事件风险分层方面非劣效。
研究设计与样本
- 前瞻性、连续入组、随机对照研究,在两家医院纳入有CCTA指征的成人1801例(62.7 ± 11.1岁),随机分配至FAAI组893例和半自动组908例。
- 采用设备工作站进行图像处理,参考标准为有创冠状动脉造影诊断阻塞性CAD(≥ 50%狭窄),随访2年评估心血管事件。
- 非劣效界值为诊断准确率和C指数差异3个百分点。
诊断标准与关键数值
- 阻塞性CAD定义为狭窄≥ 50%,FAAI组诊断准确率94.7%(89.9-97.7%),半自动组94.3%(89.5-97.4%),差值0.4%。
- FAAI组C统计量0.75(0.67-0.83),半自动组0.74(0.66-0.82),差值1%,用于心血管事件风险分层。
临床应用与阅片要点
- 全自动人工智能图像处理可缩短图像处理时间,并保持对阻塞性CAD的高诊断准确性和心血管事件风险分层能力。
- 全自动化可能促进CCTA在冠状动脉疾病早期检测中的应用。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To prospectively investigate whether fully automated artificial intelligence (FAAI)-based coronary CT angiography (CCTA) image processing is non-inferior to semi-automated mode in efficiency, diagnostic ability, and risk stratification of coronary artery disease (CAD).
MATERIALS AND METHODS: Adults with indications for CCTA were prospectively and consecutively enrolled at two hospitals and randomly assigned to either FAAI-based or semi-automated image processing using equipment workstations. Outcome measures were workflow efficiency, diagnostic accuracy for obstructive CAD (≥ 50% stenosis), and cardiovascular events at 2-year follow-up. The endpoints included major adverse cardiovascular events, hospitalization for unstable angina, and recurrence of cardiac symptoms. The non-inferiority margin was 3 percentage difference in diagnostic accuracy and C-index.
RESULTS: In total, 1801 subjects (62.7 ± 11.1 years) were included, of whom 893 and 908 were assigned to the FAAI-based and semi-automated modes, respectively. Image processing times were 121.0 ± 18.6 and 433.5 ± 68.4 s, respectively (p <0.001). Scan-to-report release times were 6.4 ± 2.7 and 10.5 ± 3.8 h, respectively (p < 0.001). Of all subjects, 152 and 159 in the FAAI-based and semi-automated modes, respectively, subsequently underwent invasive coronary angiography. The diagnostic accuracies for obstructive CAD were 94.7% (89.9-97.7%) and 94.3% (89.5-97.4%), respectively (difference 0.4%). Of all subjects, 779 and 784 in the FAAI-based and semi-automated modes were followed for 589 ± 182 days, respectively, and the C-statistic for cardiovascular events were 0.75 (0.67 to 0.83) and 0.74 (0.66 to 0.82) (difference 1%).
CONCLUSIONS: FAAI-based CCTA image processing significantly improves workflow efficiency than semi-automated mode, and is non-inferior in diagnosing obstructive CAD and risk stratification for cardiovascular events.
CLINICAL RELEVANCE STATEMENT: Conventional coronary CT angiography image processing is semi-automated. This observation shows that fully automated artificial intelligence-based image processing greatly improves efficiency, and maintains high diagnostic accuracy and the effectiveness in stratifying patients for cardiovascular events.
KEY POINTS: • Coronary CT angiography (CCTA) relies heavily on high-quality and fast image processing. • Full-automation CCTA image processing is clinically non-inferior to the semi-automated mode. • Full automation can facilitate the application of CCTA in early detection of coronary artery disease.
引用
- Zhang Y, Feng Y, Sun J, et al. Fully automated artificial intelligence-based coronary CT angiography image processing: efficiency, diagnostic capability, and risk stratification. Eur Radiol. 2024. PMID: 38193925. doi:10.1007/s00330-023-10494-6
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。