降主动脉慢性主动脉夹层假腔血流动力学与部分血栓形成
该回顾性单中心研究纳入68例降主动脉慢性主动脉夹层患者,采用4D flow CMR定量分析假腔血流动力学与生物力学,发现假腔动能可区分部分血栓形成与无血栓患者,且动能与假腔流入量独立相关于血栓范围,提示无创血流动力学评估可能对患者管理有重要价值。
要点
- 假腔动能可区分部分血栓形成与无血栓患者(多因素logistic回归p=0.038)。
- 假腔动能(p=0.006)与假腔流入量(p=0.002)独立相关于血栓范围。
- 涡流、血流加速与停滞、壁面剪切应力及脉搏波速度与血栓存在和范围关联有限。
核心结论
- 在降主动脉慢性主动脉夹层患者中,假腔动能与假腔血栓的存在及范围相关。
研究设计与样本
- 回顾性单中心研究,纳入68例降主动脉慢性主动脉夹层后假腔无血栓或部分血栓患者,行CTA、CMR血管成像及4D flow CMR检查。
诊断标准与关键数值
- 多因素logistic回归显示假腔动能可区分33例部分假腔血栓患者与35例无血栓患者(p=0.038)。
- 分离多因素线性相关显示假腔动能(p=0.006)与假腔流入量(p=0.002)独立相关于血栓范围(假腔血栓百分比)。
- 假腔涡流、血流加速与停滞、壁面剪切应力及脉搏波速度与血栓存在和范围的关联有限。
临床应用与阅片要点
- 作者指出,在降主动脉慢性主动脉夹层患者中,假腔血流动力学参数与假腔血栓形成及其范围密切相关,这些无创指标可能对患者管理有重要意义。
- 原文要点指出,部分假腔血栓形成与慢性降主动脉夹层患者的主动脉增长相关,因此识别促血栓形成的血流条件是有意义的。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Partial thrombosis of the false lumen (FL) in patients with chronic aortic dissection (AD) of the descending aorta has been associated with poor outcomes. Meanwhile, the fluid dynamic and biomechanical characteristics associated with partial thrombosis remain to be elucidated. This retrospective, single-center study tested the association between FL fluid dynamics and biomechanics and the presence and extent of FL thrombus.
METHODS: Patients with chronic non-thrombosed or partially thrombosed FLs in the descending aorta after an aortic dissection underwent computed tomography angiography, cardiovascular magnetic resonance (CMR) angiography, and a 4D flow CMR study. A comprehensive quantitative analysis was performed to test the association between FL thrombus presence and extent (percentage of FL with thrombus) and FL anatomy (diameter, entry tear location and size), fluid dynamics (inflow, rotational flow, wall shear stress, kinetic energy, and flow acceleration and stasis), and biomechanics (pulse wave velocity).
RESULTS: Sixty-eight patients were included. In multivariate logistic regression FL kinetic energy (p = 0.038) discriminated the 33 patients with partial FL thrombosis from the 35 patients with no thrombosis. Similarly, in separated multivariate linear correlations kinetic energy (p = 0.006) and FL inflow (p = 0.002) were independently related to the extent of the thrombus. FL vortexes, flow acceleration and stasis, wall shear stress, and pulse wave velocity showed limited associations with thrombus presence and extent.
CONCLUSION: In patients with chronic descending aorta dissection, false lumen kinetic energy is related to the presence and extent of false lumen thrombus.
CLINICAL RELEVANCE STATEMENT: In patients with chronic aortic dissection of the descending aorta, false lumen hemodynamic parameters are closely linked with the presence and extent of false lumen thrombosis, and these non-invasive measures might be important in patient management.
KEY POINTS: • Partial false lumen thrombosis has been associated with aortic growth in patients with chronic descending aortic dissection; therefore, the identification of prothrombotic flow conditions is desirable. • The presence of partial false lumen thrombosis as well as its extent was related with false lumen kinetic energy. • The assessment of false lumen hemodynamics may be important in the management of patients with chronic aortic dissection of the descending aorta.
引用
- Ruiz-Muñoz A, Guala A, Dux-Santoy L, et al. False lumen hemodynamics and partial thrombosis in chronic aortic dissection of the descending aorta. Eur Radiol. 2024. PMID: 38183450. doi:10.1007/s00330-023-10513-6