文献速递心血管外周血管CTDSA

基于冠状动脉CT血管成像的形态学指数预测血流动力学显著性冠状动脉狭窄

Coronary CT Angiography-based Morphologic Index for Predicting Hemodynamically Significant Coronary Stenosis.
PubMed 文献 · Radiol Cardiothorac Imaging · 2023-01-01

前瞻性两中心研究纳入133例受试者共210条狭窄冠状动脉,提出结合病变入口角度的新CCTA指数α×LL/MLD4,以侵入性FFR≤0.80为参考标准,其诊断准确率86.2%、AUC 0.93,高于LL/MLD4的80.5%、0.84及直径狭窄的0.63。

要点

  • 新指数α×LL/MLD4在CCTA上结合病变入口角度、病变长度与最小管腔直径,用于预测血流动力学显著性狭窄。
  • α×LL/MLD4的AUC 0.93高于LL/MLD4的0.84和直径狭窄的0.63(均P < .001)。
  • α×LL/MLD4的敏感度83.1%、特异度88.4%,高于LL/MLD4的66.3%、90.9%。

核心结论

  • 结合病变入口角度的新形态学指数α×LL/MLD4在检测血流动力学显著性病变方面,诊断性能高于直径狭窄和LL/MLD4。

研究设计与样本

  • 前瞻性研究,2016年9月至2020年3月从两个中心纳入受试者,均行CCTA后行侵入性冠状动脉造影(ClinicalTrials.gov标识NCT03054324)。

诊断标准与关键数值

  • 以侵入性FFR≤0.80为参考标准;α×LL/MLD4的AUC 0.93,高于LL/MLD4的0.84和直径狭窄的0.63(均P < .001)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Purpose To develop a new coronary CT angiography (CCTA)-based index, α×LL/MLD4, that considers lesion entrance angle (α) in addition to lesion length (LL) and minimal lumen diameter (MLD) and to evaluate its efficacy in predicting hemodynamically significant coronary stenosis compared with invasive coronary angiography (ICA)-derived fractional flow reserve (FFR). Materials and Methods This prospective study enrolled participants (September 2016-March 2020) from two centers who underwent CCTA followed by ICA (ClinicalTrials.gov identifier: NCT03054324). CCTA images were processed semiautomatically to measure LL, MLD, and α for calculating α×LL/MLD4. Diagnostic performance and accuracy of α×LL/MLD4 and LL/MLD4 in detecting hemodynamically significant coronary stenosis were compared against the reference standard (invasive FFR ≤ 0.80). Results In total, 133 participants (mean age, 63 years ± 9 [SD]; 99 [74%] men) with 210 stenosed coronary arteries were analyzed. Median α×LL/MLD4 was 54.0 degree/mm3 (IQR, 25.3-128.7) in participants with invasive FFR of 0.80 or less and 6.7 degree/mm3 (IQR, 3.3-12.8) in participants with invasive FFR of more than 0.80 (P < .001). The per-vessel accuracy, sensitivity, specificity, positive predictive value, and negative predictive value for discriminating ischemic lesions were 86.2%, 83.1%, 88.4%, 84.1%, and 87.7% for α×LL/MLD4 and 80.5%, 66.3%, 90.9%, 84.3%, and 78.6% for LL/MLD4, respectively. Area under the receiver operating characteristic curve for discriminating hemodynamically significant stenosis was 0.93 for α×LL/MLD4, which was significantly greater than the values of 0.84 for LL/MLD4 and 0.63 for diameter stenosis (both P < .001). Conclusion The new morphologic index, α×LL/MLD4, incorporating lesion entrance angle achieved higher diagnostic performance in detecting hemodynamically significant lesions compared with diameter stenosis and LL/MLD4. Keywords: CT Angiography, Cardiac, Coronary Arteries, Ischemia, Infarction, Technology Assessment Clinical trial registration no. NCT03054324 Supplemental material is available for this article. © RSNA, 2023 See also the commentary by Fairbairn and Nørgaard in this issue.

来源:Radiol Cardiothorac Imaging,查看原文。版权归原作者所有。

引用

  1. Wang C, Leng S, Tan RS, et al. Coronary CT Angiography-based Morphologic Index for Predicting Hemodynamically Significant Coronary Stenosis. Radiol Cardiothorac Imaging. 2023. PMID: 38166346. doi:10.1148/ryct.230064

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。