文献速递胸部MR

T2加权MRI对比度联合DWI评估实性肺腺癌病理分级的价值

The value of T2-weighted MRI contrast ratio combined with DWI in evaluating the pathological grade of solid lung adenocarcinoma.
PubMed 文献 · Clin Radiol · 2023-12-21

回顾性分析153例实性肺腺癌患者(2017年1月至2022年5月,西安交通大学第一附属医院)的临床和影像资料,按2020年IASLC病理分级系统分为低级别组(G1和G2,103例)和高级别组(G3,50例)。评估T2加权对比度(T2CR)和表观扩散系数(ADC)值对病理分级的预测价值。结果显示高级别组ADC值较低级别组低(p=0.004),T2CR较高级别组高(p=0.011);ADC和T2CR鉴别高级别与低级别腺癌的AUC分别为0.645和0.627;联合T2CR、ADC、性别和最大直径的AUC为0.778,敏感度70%,特异度75%。

要点

  • 高级别实性肺腺癌较低级别组ADC值更低(p=0.004)、T2CR更高(p=0.011)。
  • ADC和T2CR单独鉴别高级别与低级别腺癌的AUC分别为0.645和0.627。
  • 联合T2CR、ADC、性别和最大直径的AUC为0.778,敏感度70%,特异度75%。

核心结论

  • MRI定量参数(T2CR和ADC)有助于区分实性肺腺癌的病理分级,为肺癌精准治疗提供有价值的信息。

研究设计与样本

  • 回顾性分析2017年1月至2022年5月西安交通大学第一附属医院经组织病理学证实的153例实性肺腺癌病例(男82例,女71例,平均年龄63.2岁),按2020年国际肺癌研究协会病理分级系统分为低级别组(G1和G2)和高级别组(G3),由两名经验丰富的放射科医生独立测量T2CR和ADC值。

关键影像表现/征象

  • T2CR计算为肺部肿块/结节的T2信号强度除以右侧菱形肌的T2信号强度。
  • 高级别腺癌组ADC值较低级别组低(p=0.004)。
  • 高级别腺癌组T2CR值较低级别组高(p=0.011)。

诊断标准与关键数值

  • ADC鉴别高级别与低级别腺癌的AUC为0.645。
  • T2CR鉴别高级别与低级别腺癌的AUC为0.627。
  • 联合T2CR、ADC、性别和最大直径的AUC为0.778,敏感度70%,特异度75%。
  • 联合模型诊断效能显著优于单独T2CR(p=0.008,z=2.624)和单独ADC(p=0.007,z=2.679)。

临床应用与阅片要点

  • T2CR和ADC观察者间一致性良好(分别为0.948和0.929)。
  • 两组间最大直径和性别差异有统计学意义(分别为p<0.001和p=0.005),年龄无显著差异(p=0.980)。
  • 五种腺癌亚型中仅贴壁型和微乳头型在ADC值上显示统计学差异(p=0.047),其余亚型间无统计学差异(p>0.05)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To assess the predictive value of T2-weighted (T2W) magnetic resonance imaging (MRI) in combination with diffusion-weighted imaging (DWI) for determining the pathological grading of solid lung adenocarcinoma.

MATERIALS AND METHODS: The clinical and imaging data from 153 cases of solid lung adenocarcinoma (82 men, 71 women, mean age 63.2 years) confirmed at histopathology in The First Affiliated Hospital of Xi'an Jiaotong University from January 2017 to May 2022 were analysed retrospectively. Adenocarcinomas were classified into low-grade (G1 and G2) and high-grade (G3) groups following the 2020 pathological grading system proposed by the International Association for the Study of Lung Cancer. The T2-weighted contrast ratio (T2CR), calculated as the T2 signal intensity of the lung mass/nodule divided by the T2 signal intensity of the right rhomboid muscle was utilised. Two experienced radiologists reviewed the MRI images independently, measured the T2CR, and obtained apparent diffusion coefficient (ADC) values. The Mann-Whitney U-test was used to compare general characteristics (sex, age, maximum diameter), T2CR, and ADC values between the low-grade and high-grade groups. The non-parametric Kruskal-Wallis test determined differences in T2CR and ADC values among the five adenocarcinoma subtypes. Receiver characteristic curve (ROC) analysis, along with area under the curve (AUC) calculation, assessed the effectiveness of each parameter in distinguishing the pathological grade of lung adenocarcinoma. A Z-test was used to compare the AUC values.

RESULTS: Among the 153 patients with adenocarcinoma, 103 had low-grade adenocarcinoma, and 50 had high-grade adenocarcinoma. The agreement between T2CR and ADC observers was good (0.948 and 0.929, respectively). None of the parameters followed a normal distribution (p<0.05). The ADC value was lower in the high-grade adenocarcinoma group compared to the low-grade adenocarcinoma group (p=0.004), while the T2CR value was higher in the high-grade group (p=0.011). Statistically significant differences were observed in maximum diameter and gender between the two groups (p<0.001 and p=0.005, respectively), while no significant differences were noted in age (p=0.980). Among the five adenocarcinoma subtypes, only the lepidic and micropapillary subtypes displayed statistical differences in ADC values (p=0.047), with the remaining subtypes showing no statistical differences (p>0.05). The AUC values for distinguishing high-grade adenocarcinoma from low-grade adenocarcinoma were 0.645 for ADC and 0.627 for T2CR. Combining T2CR, ADC, sex, and maximum diameter resulted in an AUC of 0.778, sensitivity of 70%, and specificity of 75%. This combination significantly improved diagnostic efficiency compared to T2CR and ADC alone (p=0.008, z = 2.624; p=0.007, z = 2.679).

CONCLUSION: The MRI quantitative parameters are useful for distinguishing the pathological grades of solid lung adenocarcinoma, offering valuable insights for precise lung cancer treatment.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Dang S, Han D, Duan H, et al. The value of T2-weighted MRI contrast ratio combined with DWI in evaluating the pathological grade of solid lung adenocarcinoma. Clin Radiol. 2023. PMID: 38216369. doi:10.1016/j.crad.2023.12.005

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。