儿童和青少年胸部对比增强超声:评估附加诊断价值的初步研究
该初步研究回顾了2016至2020年间16例患者(10例男性)的18次胸部对比增强超声(CEUS)检查,并与同日常规超声对比,由4名对临床和其他影像资料设盲的放射科医生独立判读。CEUS与金标准的中位一致率(100%)显著高于常规超声(50%;P=0.004),CEUS敏感度(54.6%-81.8%)和特异度(63.4%-100.0%)均高于常规超声(分别为45.5%-72.7%和12.5%-63.5%)。作者认为CEUS对多种胸部异常的评估有附加诊断价值,数据支持进一步评估其作为无创问题解决技术的作用。
要点
- CEUS与金标准的中位一致率为100%,显著高于常规超声的50%(P=0.004)。
- CEUS中位判读信心为高(3.0分),常规超声为低至中等(1.5分)(P<0.001)。
- CEUS敏感度54.6%-81.8%、特异度63.4%-100.0%,均高于常规超声。
核心结论
- CEUS对多种胸部异常的评估有附加诊断价值,数据支持进一步评估其作为儿童无创问题解决技术的作用。
研究设计与样本
- 初步研究,回顾2016至2020年间16例患者(10例男性)的18次CEUS检查,并与同日常规超声对比;4名放射科医生对临床和其他影像资料设盲独立判读。
诊断标准与关键数值
- CEUS敏感度54.6%-81.8%,特异度63.4%-100.0%;常规超声敏感度45.5%-72.7%,特异度12.5%-63.5%。
- CEUS假阳性0-4例、假阴性2-5例,常规超声假阳性4-7例、假阴性3-6例。
- CEUS判读信心中位数为高(3.0分),常规超声为低至中等(1.5分)(P<0.001)。
- CEUS与金标准的中位一致率为100%,常规超声为50%(P=0.004)。
- 除一对判读者一致性为中等(κ=0.78,P<0.01)外,CEUS其余判读者对间一致性无统计学意义(κ=0.25-0.51,P≥0.07);常规超声有3对判读者一致性中等且有统计学意义(κ=0.55-0.78),其余3对无统计学意义(P≥0.06)。
局限性
- 原文标题标明为初步研究(Pilot Study),数据支持进一步评估CEUS的作用。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To determine the added diagnostic value of contrast-enhanced ultrasound (CEUS) in pediatric chest abnormalities by comparing interpretation of CEUS studies and confidence level to conventional US studies.
METHODS: CEUS studies in patients with a variety of clinically suspected chest abnormalities performed between 2016 and 2020 were reviewed and compared to same-day conventional US studies. Examinations were independently interpreted by 4 radiologists blinded to clinical and other imaging data. Rater confidence was classified as low, moderate, or high. Diagnostic accuracy was determined by comparing image interpretation to patient outcome as the ground truth. Interobserver agreement was also assessed.
RESULTS: Sixteen patients (10 male) with 18 CEUS studies were included. Median rater agreement with ground truth was significantly higher for CEUS (100%) than conventional US (50%; P = .004). Median rater confidence was high (3.0) for CEUS, and low-moderate (1.5) for conventional US (P < .001). CEUS sensitivity (54.6-81.8%) and specificity (63.4-100.0%) were greater than conventional US (45.5-72.7% and 12.5-63.5%, respectively). CEUS false positives (0-4) and false negatives (2-5) were fewer than conventional US (4-7 and 3-6, respectively). Except for one rater pair where agreement was substantial (κ = .78, P < .01), inter-rater agreement for CEUS for all other rater pairs was nonsignificant (κ = .25-0.51, P ≥ .07). Agreement for conventional US was moderate and statistically significant for 3 rater pairs (κ = .55-0.78) and nonsignificant for the remaining 3 rater pairs (P ≥ .06).
CONCLUSIONS: CEUS adds diagnostic value to the assessment of a variety of chest abnormalities. The data support further evaluation of the role of CEUS as a non-invasive, problem-solving technique in children.
引用
- Park HJ, Winant AJ, Lee EY, et al. Contrast-Enhanced Ultrasound of the Chest in Children and Adolescents: A Pilot Study for Assessment of Added Diagnostic Value. J Ultrasound Med. 2024. PMID: 38189176. doi:10.1002/jum.16395
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。