肺癌筛查低剂量CT上附着于纵隔胸膜或膈胸膜结节的影像学特征
本研究回顾两个数据库的胸部CT,评估低剂量CT上附着于纵隔胸膜或膈胸膜的非钙化结节(M/DP-NCN)中边缘光滑且呈三角形或透镜状/卵圆形/半圆形(LOS)者的肺癌风险。A组1451例肺癌患者中164个恶性M/DP-NCN均无光滑边缘且呈三角形或LOS形状(比例95%CI上限0.02);B组345例筛查参与者中240个此类结节在中位随访57.8个月后均无恶性,支持Lung Imaging Reporting and Data System 2022版推荐年度随访而非立即处理。
要点
- 低剂量CT上光滑边缘且呈三角形或LOS形状的纵隔/膈胸膜附着实性结节恶性风险极低。
- A组164个恶性M/DP-NCN均不具备光滑边缘且三角形或LOS形状。
- B组240个具此特征的M/DP-NCN中位随访57.8个月均无恶性。
核心结论
- 低剂量CT上光滑边缘且呈三角形或LOS形状的实性M/DP-NCN肺癌风险极低,支持Lung Imaging Reporting and Data System 2022版推荐年度随访而非立即处理。
研究设计与样本
- 回顾性研究,复习两个数据库的胸部CT。
- A组1451例肺癌患者,首次表现为平均直径3.0-30.0 mm的实性结节。
- B组345例连续肺癌筛查参与者,基线CT至少一个直径3.0-30.0 mm实性结节且至少三次随访CT。
- 放射科医师阅片识别实性M/DP-NCN,定义为距纵隔或膈胸膜0 mm的结节,记录平均直径、边缘和形状。
关键影像表现/征象
- A组1451例肺癌患者中163例(中位年龄68岁,IQR 61.5-75.0岁;92例男性)有164个恶性M/DP-NCN,平均直径3.0-30.0 mm。
- 164个恶性M/DP-NCN均无光滑边缘且呈三角形或LOS形状(比例95%CI上限0.02)。
- B组345例筛查参与者中146例(中位年龄65岁,IQR 59-71岁;81例女性)有240个M/DP-NCN,平均直径3.0-30.0 mm。
- B组中光滑边缘且呈三角形或LOS形状的M/DP-NCN在中位随访57.8个月(IQR 46.3-68.1个月)后均无恶性。
诊断标准与关键数值
- 实性M/DP-NCN定义为距纵隔或膈胸膜0 mm的结节,平均直径3.0-30.0 mm。
- 边缘光滑且呈三角形或LOS形状的M/DP-NCN恶性比例极低(95%CI上限0.02)。
临床应用与阅片要点
- 低剂量CT上光滑边缘且呈三角形或LOS形状的实性M/DP-NCN可参照Lung Imaging Reporting and Data System 2022版推荐年度随访而非立即处理。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background Pulmonary noncalcified nodules (NCNs) attached to the fissural or costal pleura with smooth margins and triangular or lentiform, oval, or semicircular (LOS) shapes at low-dose CT are recommended for annual follow-up instead of immediate workup. Purpose To determine whether management of mediastinal or diaphragmatic pleura-attached NCNs (M/DP-NCNs) with the same features as fissural or costal pleura-attached NCNs at low-dose CT can follow the same recommendations. Materials and Methods This retrospective study reviewed chest CT examinations in participants from two databases. Group A included 1451 participants who had lung cancer that was first present as a solid nodule with an average diameter of 3.0-30.0 mm. Group B included 345 consecutive participants from a lung cancer screening program who had at least one solid nodule with a diameter of 3.0-30.0 mm at baseline CT and underwent at least three follow-up CT examinations. Radiologists reviewed CT images to identify solid M/DP-NCNs, defined as nodules 0 mm in distance from the mediastinal or diaphragmatic pleura, and recorded average diameter, margin, and shape. General descriptive statistics were used. Results Among the 1451 participants with lung cancer in group A, 163 participants (median age, 68 years [IQR, 61.5-75.0 years]; 92 male participants) had 164 malignant M/DP-NCNs 3.0-30.0 mm in average diameter. None of the 164 malignant M/DP-NCNs had smooth margins and triangular or LOS shapes (upper limit of 95% CI of proportion, 0.02). Among the 345 consecutive screening participants in group B, 146 participants (median age, 65 years [IQR, 59-71 years]; 81 female participants) had 240 M/DP-NCNs with average diameter 3.0-30.0 mm. None of the M/DP-NCNs with smooth margins and triangular or LOS shapes were malignant after a median follow-up of 57.8 months (IQR, 46.3-68.1 months). Conclusion For solid M/DP-NCNs with smooth margins and triangular or LOS shapes at low-dose CT, the risk of lung cancer is extremely low, which supports the recommendation of Lung Imaging Reporting and Data System version 2022 for annual follow-up instead of immediate workup. © RSNA, 2024 See also the editorial by Goodman and Baruah in this issue.
引用
- Zhu Y, Yip R, Zhang J, et al. Radiologic Features of Nodules Attached to the Mediastinal or Diaphragmatic Pleura at Low-Dose CT for Lung Cancer Screening. Radiology. 2024. PMID: 38165250. doi:10.1148/radiol.231219
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。