文献速递儿科影像胸部MR

先天性肺气道畸形中纵隔移位角的评估:一种新的胎儿磁共振成像先天性肺疾病指标

Assessment of mediastinal shift angles in congenital pulmonary airway malformation: a new fetal magnetic resonance imaging indicator of congenital lung disease.
PubMed 文献 · Pediatr Radiol · 2024-01-29

本研究在124例无肺异常胎儿中建立左右纵隔移位角正常范围,并在32例病理诊断为先天性肺气道畸形的胎儿中测量纵隔移位角,发现右侧/左侧纵隔移位角均值在对照组为18.6°/26.3°、在先天性肺气道畸形组为39.2°/35.9°,纵隔移位角与先天性肺气道畸形体积比呈正相关,曲线下面积为0.76,作者认为纵隔移位角有潜力替代先天性肺气道畸形体积比用于评估胎儿磁共振中先天性肺气道畸形的严重程度。

要点

  • 正常胎儿右侧/左侧纵隔移位角均值分别为18.6°/26.3°。
  • 先天性肺气道畸形胎儿右侧/左侧纵隔移位角均值分别为39.2°/35.9°。
  • 纵隔移位角与先天性肺气道畸形体积比呈正相关,曲线下面积0.76。

核心结论

  • 纵隔移位角有潜力替代先天性肺气道畸形体积比用于评估胎儿磁共振中先天性肺气道畸形的严重程度。

研究设计与样本

  • 研究在124例无肺异常胎儿(对照组)中测量双侧纵隔移位角以建立正常范围,并在32例病理诊断为先天性肺气道畸形的胎儿中测量纵隔移位角,比较纵隔移位角与先天性肺气道畸形体积比。

诊断标准与关键数值

  • 正常胎儿右侧/左侧纵隔移位角均值分别为18.6°/26.3°。
  • 先天性肺气道畸形胎儿右侧/左侧纵隔移位角均值分别为39.2°/35.9°。
  • 纵隔移位角与先天性肺气道畸形体积比呈正相关。
  • 纵隔移位角的曲线下面积为0.76,显示出高判别准确度。

临床应用与阅片要点

  • 作者认为纵隔移位角有潜力替代先天性肺气道畸形体积比用于评估胎儿磁共振中先天性肺气道畸形的严重程度。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: The mediastinal shift angle is a new fetal magnetic resonance imaging (MRI) index that is reportedly correlated with postnatal survival in fetuses with congenital diaphragmatic hernia. However, its correlation in patients with congenital pulmonary airway malformation (CPAM) has not been assessed.

OBJECTIVE: This study aimed to establish a normal range for the right/left mediastinal shift angles, to evaluate the mediastinal shift angle in fetuses with CPAM, to compare the mediastinal shift angle with the CPAM volume ratio, and to evaluate the predictive value of the mediastinal shift angle measurements.

MATERIALS AND METHODS: To establish the normal range, we measured the mediastinal shift angle bilaterally in 124 fetuses without any lung abnormality (the control group). Subsequently, the mediastinal shift angle was measured in 32 fetuses pathologically diagnosed with CPAM. Moreover, the mediastinal shift angle and CPAM volume ratio were compared using fetal MRI.

RESULTS: The mean values for the right/left mediastinal shift angles were 18.6°/26.3° and 39.2°/35.9° for control fetuses and fetuses with CPAM, respectively. The mediastinal shift angle and the CPAM volume ratio showed a positive statistical correlation. The area under the curve demonstrated high discriminatory accuracy for the mediastinal shift angle (0.76).

CONCLUSION: The mediastinal shift angle has potential to replace the CPAM volume ratio for evaluating the severity of CPAM in fetal MRI.

来源:Pediatr Radiol,查看原文。版权归原作者所有。

引用

  1. Tsukamoto J, Miyazaki O, Saito Y, et al. Assessment of mediastinal shift angles in congenital pulmonary airway malformation: a new fetal magnetic resonance imaging indicator of congenital lung disease. Pediatr Radiol. 2024. PMID: 38285191. doi:10.1007/s00247-024-05852-5

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。