双层光谱探测器CT在喉及下咽鳞状细胞癌术前T分期中的价值
纳入67例喉及下咽鳞状细胞癌患者,比较双层光谱探测器CT的40–100 keV虚拟单能量图像与常规多能图像的图像质量,并以临床T分期为参考标准评估T分期准确率。40–50 keV虚拟单能量图像质量优于常规图像,40 keV虚拟单能量图像T分期准确率0.86,高于常规图像的0.63(P < 0.001)。
要点
- 40–50 keV虚拟单能量图像上肿瘤与胸锁乳突肌对比度、SNR、CNR及主观评分均高于常规图像(P < 0.05)。
- 40–100 keV虚拟单能量图像噪声均低于常规图像(P < 0.05)。
- 40 keV虚拟单能量图像T分期准确率0.86,常规图像0.63(P < 0.001)。
核心结论
- 40–50 keV虚拟单能量图像质量高于常规多能图像,40 keV虚拟单能量图像诊断准确率优于常规图像,最适合用于喉及下咽鳞状细胞癌术前T分期。
研究设计与样本
- 共纳入67例喉及下咽鳞状细胞癌患者,评估双层光谱探测器CT的40–100 keV虚拟单能量图像与常规多能图像的肿瘤与胸锁乳突肌对比度、SNR、CNR、图像噪声及五点法主观图像质量,以临床T分期为参考标准评估T分期准确率。
诊断标准与关键数值
- 40 keV虚拟单能量图像T分期准确率为0.86,常规多能图像为0.63(P < 0.001);40–50 keV虚拟单能量图像的肿瘤与胸锁乳突肌对比度、SNR、CNR及主观评分高于常规图像(P < 0.05);40–100 keV虚拟单能量图像噪声低于常规图像(P < 0.05)。
临床应用与阅片要点
- 作者结论认为40 keV虚拟单能量图像最适合用于喉及下咽鳞状细胞癌术前T分期。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To explore the optimal kiloelectron voltage (keV) of virtual monochromatic images (VMIs) of dual-layer spectral detector computed tomography (DLSCT) to display laryngeal and hypopharyngeal squamous cell carcinoma (LHSCC) and its diagnostic performance for preoperative T staging of LHSCC.
METHODS: A total of 67 LHSCC patients were included, and the contrast between the tumor and sternocleidomastoid muscle (SM), signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and image noise of 40-100 keV VMIs and conventional polyenergetic images (CIs) were evaluated. The image quality of the CI and 40-100 keV VMI was evaluated by a five-point method. The VMI with the best image quality was screened out, and the accuracy of the optimal keV VMI and CI for T staging was assessed using clinical T staging as the reference standard.
RESULTS: The contrast between the tumor and SM, SNR, CNR and subjective image quality scores of LHSCC on 40-50 keV VMIs were higher than those on CIs (P < 0.05); the image noises of 40-100 keV VMIs were lower than those of CIs (P < 0.05). The 40 keV VMI had the highest SNR, CNR and subjective score of image quality. The accuracy rates of the 40 keV VMI and CI for T staging of LHSCC were 0.86 and 0.63 (P < 0.001), respectively.
CONCLUSION: The image quality of 40-50 keV VMI is higher than that of CI, and the diagnostic accuracy of 40 keV VMI is better than that of CI, which is most suitable for preoperative T staging of LHSCC.
引用
- Zheng T, Xiao Y, Yang F, et al. The value of dual-layer spectral detector CT in preoperative T staging of laryngeal and hypopharyngeal squamous cell carcinoma. Eur J Radiol. 2024. PMID: 38176085. doi:10.1016/j.ejrad.2024.111287
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。