文献速递头颈技术与安全CTMR

基于深度学习自配置nnU-Net在CT和MRI上对口咽鳞状细胞癌的多模态分割

Deep learning-based multimodal segmentation of oropharyngeal squamous cell carcinoma on CT and MRI using self-configuring nnU-Net.
PubMed 文献 · Eur Radiol · 2024-01-20

单中心回顾性研究纳入91例口咽鳞状细胞癌患者,用自配置nnU-Net在CT、MR及配准CT-MR图像上训练分割模型。测试队列中MR和CT-MR模型的Hausdorff距离显著低于CT模型,MR模型影像组学特征ICC为0.91-0.93。结论认为nnU-Net在CT和MRI上分割口咽鳞癌可靠准确。

要点

  • MR模型在测试队列2的DSC为0.77±0.08,CT-MR模型为0.73±0.18,CT模型仅为0.57±0.31。
  • CT-MR模型Hausdorff距离1.57±1.06 mm、MR模型1.36±0.61 mm,均显著低于CT模型3.48±5.0 mm。
  • MR模型影像组学特征平均ICC为0.91-0.93,提示分割可重复性良好。

核心结论

  • 自配置nnU-Net在CT和MRI上对口咽鳞状细胞癌实现了可靠且准确的分割。
  • 多模态CT-MR模型在CT和MRI同步分割上显示出有前景的结果。

研究设计与样本

  • 单中心回顾性研究,纳入91例口咽鳞状细胞癌患者,分为开发队列56例、测试队列1共13例、测试队列2共22例。
  • 在开发队列中于CT、MR及配准CT-MR图像上手工分割作为参考标准,采用自配置nnU-Net训练多模态和多通道输入图像。
  • 在测试队列中计算Dice相似系数和平均Hausdorff距离,并行Pearson相关和Bland-Altman分析及影像组学特征组内相关系数评估。

诊断标准与关键数值

  • 测试队列1的DSC:CT模型0.64±0.33、MR模型0.67±0.27、CT-MR模型0.65±0.29,各模型间DSC无显著差异。
  • 测试队列2的DSC:CT模型0.57±0.31、MR模型0.77±0.08、CT-MR模型0.73±0.18。
  • Hausdorff距离:CT-MR模型1.57±1.06 mm、MR模型1.36±0.61 mm,均显著低于CT模型3.48±5.0 mm(p=0.037和p=0.014)。
  • 参考标准与预测体积的相关系数:CT模型0.88、MR模型0.93、CT-MR模型0.9。
  • MR模型影像组学特征平均ICC为0.91-0.93。

临床应用与阅片要点

  • 基于深度学习的口咽鳞状细胞癌治疗前CT和MRI自动检测与分割有助于影像学疗效评估和放疗计划制定。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To evaluate deep learning-based segmentation models for oropharyngeal squamous cell carcinoma (OPSCC) using CT and MRI with nnU-Net.

METHODS: This single-center retrospective study included 91 patients with OPSCC. The patients were grouped into the development (n = 56), test 1 (n = 13), and test 2 (n = 22) cohorts. In the development cohort, OPSCC was manually segmented on CT, MR, and co-registered CT-MR images, which served as the ground truth. The multimodal and multichannel input images were then trained using a self-configuring nnU-Net. For evaluation metrics, dice similarity coefficient (DSC) and mean Hausdorff distance (HD) were calculated for test cohorts. Pearson's correlation and Bland-Altman analyses were performed between ground truth and prediction volumes. Intraclass correlation coefficients (ICCs) of radiomic features were calculated for reproducibility assessment.

RESULTS: All models achieved robust segmentation performances with DSC of 0.64 ± 0.33 (CT), 0.67 ± 0.27 (MR), and 0.65 ± 0.29 (CT-MR) in test cohort 1 and 0.57 ± 0.31 (CT), 0.77 ± 0.08 (MR), and 0.73 ± 0.18 (CT-MR) in test cohort 2. No significant differences were found in DSC among the models. HD of CT-MR (1.57 ± 1.06 mm) and MR models (1.36 ± 0.61 mm) were significantly lower than that of the CT model (3.48 ± 5.0 mm) (p = 0.037 and p = 0.014, respectively). The correlation coefficients between the ground truth and prediction volumes for CT, MR, and CT-MR models were 0.88, 0.93, and 0.9, respectively. MR models demonstrated excellent mean ICCs of radiomic features (0.91-0.93).

CONCLUSION: The self-configuring nnU-Net demonstrated reliable and accurate segmentation of OPSCC on CT and MRI. The multimodal CT-MR model showed promising results for the simultaneous segmentation on CT and MRI.

CLINICAL RELEVANCE STATEMENT: Deep learning-based automatic detection and segmentation of oropharyngeal squamous cell carcinoma on pre-treatment CT and MRI would facilitate radiologic response assessment and radiotherapy planning.

KEY POINTS: • The nnU-Net framework produced a reliable and accurate segmentation of OPSCC on CT and MRI. • MR and CT-MR models showed higher DSC and lower Hausdorff distance than the CT model. • Correlation coefficients between the ground truth and predicted segmentation volumes were high in all the three models.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Choi Y, Bang J, Kim SY, et al. Deep learning-based multimodal segmentation of oropharyngeal squamous cell carcinoma on CT and MRI using self-configuring nnU-Net. Eur Radiol. 2024. PMID: 38243135. doi:10.1007/s00330-024-10585-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。