文献速递神经头颈CT

颅底、眼眶与颅盖经皮CT引导活检的安全性与组织病理学阳性率

Safety and histopathologic yield of percutaneous CT-guided biopsies of the skull base, orbit, and calvarium.
PubMed 文献 · Neuroradiology · 2024-01-10

经皮CT引导空心针活检用于颅底、颅盖和眼眶病变安全且诊断阳性率高。

要点

  • 颅底病变初始诊断率32/34(94%),假阴性1例、无法诊断1例。
  • 颅盖病变初始诊断率21/23(91%),假阴性1例、无法诊断1例。
  • 眼眶病变4/4活检均诊断成功,无并发症报道。

核心结论

  • 经皮CT引导空心针活检用于颅底、颅盖和眼眶病变安全且诊断阳性率高。

研究设计与样本

  • 回顾性研究,纳入2010年1月1日至2020年10月30日期间61例经皮CT引导活检,包括颅底34例、颅盖23例、眼眶4例,记录患者人口学、病灶大小和位置、活检入路、针径、CT剂量长度乘积、并发症及组织病理学阳性率。

诊断标准与关键数值

  • 颅底病变初始诊断率32/34(94%),假阴性1例,无法诊断样本1例。
  • 颅盖病变初始诊断率21/23(91%),假阴性1例,无法诊断样本1例。
  • 总并发症率4/61(6.6%);颅底操作3例并发症(2例即刻、1例延迟),颅盖活检1例并发症,眼眶活检无并发症。

临床应用与阅片要点

  • 作者认为经皮CT引导空心针活检用于颅底、颅盖和眼眶病变可安全进行且诊断阳性率高。
  • 原文描述了针对困难活检靶点的多种入路,并综述了操作规划考虑因素和组织病理学阳性率。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Although CT-guided biopsies of the calvarium, skull base, and orbit are commonly performed, the best approaches, efficacy, and safety of such procedures remain scantly described in the literature. This retrospective review of percutaneous biopsies illustrates several approaches to challenging biopsy targets and provides a review of procedural planning considerations and histopathologic yield.

METHODS: A retrospective review of CT-guided biopsies of the skull base, calvarium, and orbit between 1/1/2010 and 10/30/2020 was conducted. Patient demographics and procedural factors were recorded, including lesion size and location, biopsy approach, and needle gauge. Outcomes were also noted, including CT dose length product, complications, and histopathologic yield.

RESULTS: Sixty-one CT-guided biopsies were included in the final analysis: 34 skull base, 23 calvarial, and 4 orbital lesions. The initial diagnostic yield was 32/34 (94%) for skull base lesions, with one false-negative and one non-diagnostic sample. Twenty-one of twenty-three (91%) biopsies in the calvarium were initially diagnostic, with one false-negative and one non-diagnostic sample. In the orbit, 4/4 biopsies were diagnostic. The total complication rate for the cohort was 4/61 (6.6%). Three complications were reported in skull base procedures (2 immediate and 1 delayed). A single complication was reported in a calvarial biopsy, and no complications were reported in orbital biopsies.

CONCLUSION: Percutaneous CT-guided core needle biopsies can be performed safely and with a high diagnostic yield for lesions in the skull base, calvarium, and orbit.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. Betting T, Benson JC, Madhavan A, et al. Safety and histopathologic yield of percutaneous CT-guided biopsies of the skull base, orbit, and calvarium. Neuroradiology. 2024. PMID: 38197949. doi:10.1007/s00234-023-03266-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。