文献速递神经技术与安全MR

脉络丛作为识别动脉输入函数以计算MRI脑灌注指标的替代位点

The Choroid Plexus as an Alternative Locus for the Identification of the Arterial Input Function for Calculating Cerebral Perfusion Metrics Using MRI.
PubMed 文献 · AJNR Am J Neuroradiol · 2023-12-29

研究纳入8名健康参与者和7名胶质瘤患者,比较分别以大脑中动脉和脉络丛作为动脉输入函数计算的静息灌注指标;结果发现同一参与者中,两种动脉输入函数计算的灰质和白质静息灌注指标无系统性差异;结论认为当大脑中动脉无法获得合适测量时,脉络丛可作为动脉输入函数的替代采样位置。

要点

  • 同一参与者中以大脑中动脉或脉络丛作为动脉输入函数,计算的灰质和白质静息灌注指标无系统性差异。
  • 当大脑中动脉因颅底磁敏感伪影或狭窄闭塞性疾病变细而不适合选为动脉输入函数时,脉络丛可作为替代采样位置。
  • 脉络丛是高度血管化组织,主要由动脉化血管和无细胞基质组成,代谢需求相对其血流量较低。

核心结论

  • 脉络丛提供了动脉输入函数的替代采样位置,适用于无法在大脑中动脉获得合适测量的情况。

研究设计与样本

  • 研究纳入8名健康参与者和7名胶质瘤患者,均接受钆对比剂团注;为每位参与者分别从左侧和右侧大脑中动脉M1段及双侧侧脑室脉络丛选取动脉输入函数,比较T2*信号变化及计算的静息灌注指标。

诊断标准与关键数值

  • 以大脑中动脉或脉络丛作为动脉输入函数计算的同一参与者灰质和白质静息灌注指标无系统性差异。

临床应用与阅片要点

  • 当大脑中动脉因颅底磁敏感伪影或狭窄闭塞性疾病导致管径变细而不适合选取动脉输入函数时,可考虑以脉络丛作为替代采样位置。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: MR imaging-based cerebral perfusion metrics can be obtained by tracing the passage of a bolus of contrast through the microvasculature of the brain parenchyma. Thus, the temporal signal pattern of the contrast agent is typically measured over a large artery such as the MCA to generate the arterial input function. The largest intracranial arteries in the brain may not always be suitable for selecting the arterial input function due to skull base susceptibility artifacts or reduced size from steno-occlusive disease. Therefore, a suitable alternative arterial input function window would be useful. The choroid plexus is a highly vascular tissue composed essentially of arterialized blood vessels and acellular stroma with low metabolic requirements relative to its blood flow and may be a suitable alternative to identify the arterial input function.

MATERIALS AND METHODS: We studied 8 healthy participants and 7 patients with gliomas who were administered a bolus of gadolinium. We selected an arterial input function from both the left and right M1 segments of the MCA and both lateral ventricles of the choroid plexus for each participant. We compared the changes in the T2* signal and the calculated resting perfusion metrics using the arterial input functions selected from the MCA and choroid plexus.

RESULTS: We found no systematic difference between resting perfusion metrics in GM and WM when calculated using an arterial input function from the MCA or choroid plexus in the same participant.

CONCLUSIONS: The choroid plexus provides an alternative location from which an arterial input function may be sampled when a suitable measure over an MCA is not available.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Sobczyk O, Sayin ES, Poublanc J, et al. The Choroid Plexus as an Alternative Locus for the Identification of the Arterial Input Function for Calculating Cerebral Perfusion Metrics Using MRI. AJNR Am J Neuroradiol. 2023. PMID: 38164530. doi:10.3174/ajnr.A8099

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。