文献速递神经外周血管介入CT

双能CT诊断急性缺血性卒中血管内治疗后神经系统并发症的诊断准确性:系统评价与Meta分析

Diagnostic accuracy of dual-energy computed tomography in the diagnosis of neurological complications after endovascular treatment of acute ischaemic stroke: a systematic review and meta-analysis.
PubMed 文献 · Br J Radiol · 2024-01-01

该系统评价与Meta分析纳入22项研究(21项进入定量合成),评估双能CT检测急性缺血性卒中血管内治疗后神经系统并发症的诊断效能。检测脑出血的合并敏感度为69.9%(95%CI 44.5%-86.8%)、特异度100%(95%CI 92.1%-100%),检测缺血的合并敏感度为85.9%(95%CI 80.4%-90%)、特异度90.7%(95%CI 87%-93.5%),sROC曲线下面积分别为0.954和0.952。作者认为双能CT准确性和特异度高,但建议进一步开展采用标准化参考试验和更大样本量的前瞻性研究。

要点

  • 双能CT检测卒中血管内治疗后脑出血的合并特异度为100%(95%CI 92.1%-100%),敏感度为69.9%(95%CI 44.5%-86.8%)。
  • 双能CT检测卒中介入后缺血的合并敏感度为85.9%(95%CI 80.4%-90%),特异度为90.7%(95%CI 87%-93.5%)。
  • 双能CT检测脑出血与缺血的sROC曲线下面积分别为0.954与0.952。

核心结论

  • 双能CT检测急性缺血性卒中血管内治疗后神经系统并发症具有较高的准确性和特异度,但作者建议进一步开展采用标准化参考试验和更大样本量的前瞻性研究以支持这些发现。

研究设计与样本

  • 系统评价与Meta分析,检索Web of Science、Scopus、PubMed、EBSCO和Science Direct数据库,纳入22项研究、其中21项进入定量合成,采用Quality of Diagnostic Accuracy Studies-2工具进行质量评价,计算合并敏感度、特异度、阴性似然比、阳性似然比并构建sROC曲线估计曲线下面积。

诊断标准与关键数值

  • 双能CT检测脑出血的合并敏感度69.9%(95%CI 44.5%-86.8%)、合并特异度100%(95%CI 92.1%-100%)。
  • 双能CT检测缺血的合并敏感度85.9%(95%CI 80.4%-90%)、合并特异度90.7%(95%CI 87%-93.5%)。
  • sROC曲线下面积:检测脑出血为0.954,检测缺血为0.952。

临床应用与阅片要点

  • 作者认为双能CT是预测急性缺血性卒中血管内治疗后脑出血和脑缺血的快速、有效的影像工具。

局限性

  • 作者建议进一步开展采用标准化参考试验和更大样本量的前瞻性研究以支持这些发现。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To investigate dual-energy computed tomography's (DECT) diagnostic performance in detecting neurological complications following endovascular therapy (EVT) of acute ischaemic stroke (AIS).

METHODS: We performed the literature search using Web of Science, Scopus, PubMed, EBSCO, and Science Direct databases for published related studies. The selected studies estimated the validity of DECT in the detection of neurological complications after EVT for AIS. Study quality assessment was performed utilizing the Quality of Diagnostic Accuracy Studies-2 Tool. Our meta-analysis calculated the pooled sensitivity, negative likelihood ratio, specificity, and positive likelihood ratio for each detected complication. The summary receiver operating characteristics (sROC) curve was utilized to estimate the area under the curve (AUC).

RESULTS: Of 22 studies, 21 were included in the quantitative synthesis. In the detection of intracerebral haemorrhage (ICH), DECT pooled overall sensitivity and specificity were 69.9% (95% CI, 44.5%-86.8%) and 100% (95% CI, 92.1%-100%); whereas, in the detection of ischaemia, they were 85.9% (95% CI, 80.4%-90%) and 90.7% (95% CI, 87%-93.5%), respectively. On the sROC curve, AUC values of 0.954 and 0.952 were recorded for the detection of ICH and ischaemia, respectively.

CONCLUSIONS: DECT demonstrated high accuracy and specificity in the detection of neurological complications post-endovascular treatment of AIS. However, further prospective studies with a standardized reference test and a larger sample size are recommended to support these findings.

ADVANCES IN KNOWLEDGE: DECT is a rapid and valid imaging tool for the prediction of ICH and cerebral ischaemia after the EVT of AIS.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Ebaid NY, Mouffokes A, Yasen NS, et al. Diagnostic accuracy of dual-energy computed tomography in the diagnosis of neurological complications after endovascular treatment of acute ischaemic stroke: a systematic review and meta-analysis. Br J Radiol. 2024. PMID: 38263833. doi:10.1093/bjr/tqad007

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。