7 T 病灶衰减磁化准备梯度回波序列用于检测多发性硬化幕下脱髓鞘病灶
回顾性横断面研究纳入42例确诊多发性硬化患者,比较7 T MRI上新型LAMA序列与常规DIR及T2加权序列对脑干、小脑及上颈髓脱髓鞘病灶的检出。LAMA检出病灶数显著多于DIR+T2(均值6.4 vs 3.0,P<0.001),对比噪声比更高,阅片者间一致性更好。
要点
- LAMA在7 T MRI上检出幕下脱髓鞘病灶数显著多于DIR联合T2序列(均值6.4 vs 3.0)。
- LAMA的对比噪声比显著高于DIR和T2序列(3.7±0.9 vs 1.94±0.7 vs 1.2±0.7)。
- DIR联合T2未检出病灶的病例中,83.3%经LAMA检出至少1个病灶。
核心结论
- LAMA显著提高多发性硬化患者幕下脱髓鞘病灶的检出,与标准MP2RAGE序列联合可为准确评估多发性硬化病变范围提供有价值工具。
研究设计与样本
- 回顾性横断面研究,纳入42例确诊多发性硬化患者,均接受7 T MRI并包含LAMA、3D DIR和2D T2加权Turbo自旋回波序列。
关键影像表现/征象
- LAMA检出病灶数均值6.4,DIR联合T2检出均值3.0,LAMA显著更多(P<0.001)。
- LAMA的对比噪声比为3.7±0.9,DIR为1.94±0.7,T2为1.2±0.7,LAMA均显著更高(所有P<0.001)。
- DIR联合T2未检出病灶的病例中,83.3%经LAMA检出至少1个病灶。
- 在所有分析脑区,LAMA检出病灶数均多于DIR联合T2。
诊断标准与关键数值
- LAMA阅片者间一致性组内相关系数0.75(95%CI 0.41-0.88),DIR联合T2为0.61(95%CI 0.35-0.78)。
- 病灶计数比较采用非参数Wilcoxon符号秩检验。
- 阅片者间一致性采用组内相关系数评估。
临床应用与阅片要点
- LAMA单独分析时可检出更多幕下脱髓鞘病灶,阅片者间一致性优于DIR联合T2。
- 作者认为将LAMA与标准MP2RAGE序列联合可为准确评估多发性硬化病变范围提供有价值工具。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Detection of infratentorial demyelinating lesions in multiple sclerosis (MS) presents a challenge in magnetic resonance imaging (MRI), a difficulty that is further heightened in 7 T MRI. This study aimed to assess the efficacy of a novel MRI approach, lesion-attenuated magnetization-prepared gradient echo acquisition (LAMA), for detecting demyelinating lesions within the posterior fossa and upper cervical spine on 7 T MRI and contrast its performance with conventional double-inversion recovery (DIR) and T2-weighted turbo spin echo sequences.
MATERIALS AND METHODS: We conducted a retrospective cross-sectional study in 42 patients with a confirmed diagnosis of MS. All patients had 7 T MRI that incorporated LAMA, 3D DIR, and 2D T2-weighted turbo spin echo sequences. Three readers assessed lesion count in the brainstem, cerebellum, and upper cervical spinal cord using both DIR and T2-weighted images in one session. In a separate session, LAMA was analyzed alone. Contrast-to-noise ratio was also compared between LAMA and the conventional sequences. Lesion counts between methods were assessed using nonparametric Wilcoxon signed rank test. Interrater agreement in lesion detection was estimated by intraclass correlation coefficients.
RESULTS: LAMA identified a significantly greater number of lesions than DIR + T2 (mean 6.4 vs 3.0; P < 0.001). LAMA also exhibited better interrater agreement (intraclass correlation coefficient [95% confidence interval], 0.75 [0.41-0.88] vs 0.61 [0.35-0.78]). The contrast-to-noise ratio for LAMA (3.7 ± 0.9) significantly exceeded that of DIR (1.94 ± 0.7) and T2 (1.2 ± 0.7) (all P 's < 0.001). In cases with no lesions detected using DIR + T2, at least 1 lesion was identified in 83.3% with LAMA. Across all analyzed brain regions, LAMA consistently detected more lesions than DIR + T2.
CONCLUSIONS: LAMA significantly improves the detection of infratentorial demyelinating lesions in MS patients compared with traditional methods. Integrating LAMA with standard magnetization-prepared 2 rapid acquisition gradient echo acquisition provides a valuable tool for accurately characterizing the extent of MS disease.
引用
- Middlebrooks EH, Patel V, Zhou X, et al. 7 T Lesion-Attenuated Magnetization-Prepared Gradient Echo Acquisition for Detection of Posterior Fossa Demyelinating Lesions in Multiple Sclerosis. Invest Radiol. 2024. PMID: 38193790. doi:10.1097/RLI.0000000000001050
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。