文献速递神经外周血管MRDSA

非对比静音磁共振血管成像与时间飞跃法磁共振血管成像序列评估颅内硬脑膜动静脉瘘的比较研究

Comparative study of non-contrast silent and time-of-flight magnetic resonance angiographic sequences in the evaluation of intracranial dural arteriovenous fistula.
PubMed 文献 · Clin Radiol · 2023-12-07

前瞻性纳入40例硬脑膜动静脉瘘患者,比较静音MRA与TOF MRA在定位、Cognard分型、供血动脉及引流静脉评估中的表现,并以DSA为参考。静音MRA对供血动脉和引流静脉的敏感度高于TOF MRA,治疗策略预测准确率也更高。

要点

  • 静音MRA对供血动脉和引流静脉的敏感度高于TOF MRA(87% vs 79%;81.6% vs 67%)。
  • 静音MRA和TOF MRA对DAVF定位与分型的敏感度、准确率均高。
  • 静音MRA预测治疗策略的准确率高于TOF MRA(96% vs 85%)。

核心结论

  • 静音MRA较TOF MRA能更可靠地评估DAVF的各项血管构筑成分。

研究设计与样本

  • 前瞻性研究,连续纳入40例DAVF患者,均行静音MRA、TOF MRA和DSA检查,以DSA及后续血管内治疗为参考。

诊断标准与关键数值

  • 静音MRA与TOF MRA定位敏感度分别为96.4%和96%,定位准确率分别为96%和95%。
  • 静音MRA与TOF MRA分型敏感度分别为96%和94%,分型准确率分别为96%和93.5%。
  • 静音MRA与TOF MRA对供血动脉的敏感度分别为87%和79%,对引流静脉的敏感度分别为81.6%和67%;考虑主要供血动脉时敏感度分别提高至96.4%和89%。
  • 对即刻引流静脉的敏感度和准确率分别为92.6%和85.8%。
  • 静音MRA与TOF MRA预测治疗策略的准确率分别为96%和85%。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To compare the performance of two non-contrast magnetic resonance angiography (MRA) sequences, silent MRA and time of flight (TOF) MRA, in the evaluation of intracranial dural arteriovenous fistula (DAVF).

MATERIALS AND METHODS: Forty consecutive patients with DAVF were enrolled and evaluated prospectively using silent MRA, TOF MRA, and digital subtraction angiography (DSA). The location, Cognard classification, arterial feeders, and venous drainage were evaluated. The therapeutic strategy and possible route were predicted on both silent and TOF MRA and these were compared with DSA during subsequent endovascular treatment.

RESULTS: Sensitivity and accuracy of silent and TOF MRA for localisation (96.4% versus 96% and 96% versus 95%, respectively) and classification (96% versus 94% and 96% versus 93.5%, respectively) were high. Silent MRA showed higher sensitivity than TOF MRA for arterial feeders and draining veins (87% versus 79% and 81.6% versus 67%). This improved to a sensitivity of 96.4% and 89% when prominent feeders were considered. The sensitivity and accuracy were 92.6% and 85.8% for immediate draining veins. Both silent and TOF MRA were accurate for therapeutic planning (96% versus 85%), although silent MRA was more accurate.

CONCLUSION: Silent MRA can more reliably evaluate the various angioarchtectural components of DAVF compared to TOF MRA.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Prasad Balasubramanian A, Kumar Kannath S, Thomas B, et al. Comparative study of non-contrast silent and time-of-flight magnetic resonance angiographic sequences in the evaluation of intracranial dural arteriovenous fistula. Clin Radiol. 2023. PMID: 38182477. doi:10.1016/j.crad.2023.11.019

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。