文献速递神经介入CTDSA

小型颅内动脉瘤患者血流导向装置瘤颈贴壁不良与动脉瘤不完全闭塞的相关性:单中心经验

Correlation of Flow Diverter Malapposition at the Aneurysm Neck with Incomplete Aneurysm Occlusion in Patients with Small Intracranial Aneurysms: A Single-Center Experience.
PubMed 文献 · AJNR Am J Neuroradiol · 2023-12-29

回顾性分析2019年1月至2022年6月153例患者175个未破裂小型颅内动脉瘤,采用血流导向装置治疗,用高分辨率锥形束CT评估瘤颈贴壁情况,随访血管造影平均9.47±3.35个月显示完全闭塞率66.9%。瘤颈贴壁不良组完全闭塞率38.9%(7/18),贴壁良好组70.1%(110/157);回归分析显示瘤囊带分支血管、瘤颈贴壁不良和动脉瘤直径较大是不完全闭塞的正向预测因素。

要点

  • 瘤颈贴壁不良者完全闭塞率38.9%(7/18),贴壁良好者70.1%(110/157)。
  • 瘤囊带分支血管(OR 2.937,P=0.018)与不完全闭塞相关。
  • 瘤颈贴壁不良(OR 3.561,P=0.023)和动脉瘤直径较大(OR 1.533,P=0.028)为不完全闭塞的正向预测因素。

核心结论

  • 瘤囊带分支血管、动脉瘤直径较大及瘤颈贴壁不良显著影响小型颅内动脉瘤单纯血流导向装置治疗后的修复。

研究设计与样本

  • 回顾性分析2019年1月至2022年6月153例患者175个未破裂小型颅内动脉瘤,共植入159枚血流导向装置,采用高分辨率锥形束CT评估瘤颈贴壁,以最新随访常规血管造影(≥6个月)判断完全闭塞,多因素logistic回归分析不完全闭塞的相关因素。

关键影像表现/征象

  • 高分辨率锥形束CT于装置释放后显示瘤颈处血流导向装置贴壁不良18例。
  • 随访血管造影平均9.47±3.35个月,动脉瘤完全闭塞率为66.9%。

诊断标准与关键数值

  • 完全闭塞率:瘤颈贴壁不良组38.9%(7/18) vs 贴壁良好组70.1%(110/157)。
  • 不完全闭塞的正向预测因素:瘤囊带分支血管 OR 2.937(P=0.018);瘤颈贴壁不良 OR 3.561(P=0.023);动脉瘤直径较大 OR 1.533(P=0.028)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Flow diversion treatment repairs aneurysms by altering the hemodynamics of the aneurysmal sac and providing a scaffold for endothelial cell adhesion. The purpose of this study was to investigate the correlation of flow diverter (FD) malapposition at the aneurysm neck with incomplete occlusion of small intracranial aneurysms (IAs) and investigate other factors that are possibly related to incomplete occlusion.

MATERIALS AND METHODS: From January 2019 to June 2022, the clinical and imaging data for 153 patients (175 aneurysms) with unruptured small IAs treated with flow diversion were retrospectively analyzed. FD apposition at the aneurysm neck was evaluated by high-resolution conebeam CT (HR-CBCT), and the complete occlusion rate for aneurysms was judged according to the latest follow-up conventional angiography findings (≥6 months). Multivariate logistic regression analysis was used to determine factors associated with incomplete aneurysm occlusion.

RESULTS: In total, 159 FDs were implanted in 153 patients. HR-CBCT performed after the deployment revealed FD malapposition at the aneurysm neck in 18 cases. According to the latest follow-up angiograms (average: 9.47 ± 3.35 months), the complete aneurysm occlusion rate was 66.9%. The complete occlusion rates for incomplete and complete stent apposition at the neck were 38.9% (7/18) and 70.1% (110/157), respectively. The results of regression analysis showed that an aneurysm sac with branch vessels (OR, 2.937; P = .018), incomplete stent apposition at the aneurysm neck (OR, 3.561; P = .023), and a large aneurysm diameter (OR, 1.533; P = .028) were positive predictors of incomplete aneurysm occlusion.

CONCLUSIONS: An aneurysm sac with branch vessels, a large aneurysm diameter, and malapposition at the aneurysm neck significantly affect aneurysm repair after FD stent-only treatment for small IAs.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Long S, Shi S, Tian Q, et al. Correlation of Flow Diverter Malapposition at the Aneurysm Neck with Incomplete Aneurysm Occlusion in Patients with Small Intracranial Aneurysms: A Single-Center Experience. AJNR Am J Neuroradiol. 2023. PMID: 38164561. doi:10.3174/ajnr.A8079

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。