文献速递神经技术与安全CTMR

侧卧位动态CT脊髓造影联合实时团注跟踪(dCTM-BT)评估脑脊液-静脉瘘:按脑影像表现分层的诊断效能

Lateral Decubitus Dynamic CT Myelography with Real-Time Bolus Tracking (dCTM-BT) for Evaluation of CSF-Venous Fistulas: Diagnostic Yield Stratified by Brain Imaging Findings.
PubMed 文献 · AJNR Am J Neuroradiol · 2023-12-29

本研究回顾性纳入48例疑似自发性颅内低压且脊柱MRI无硬膜外积液的患者,采用侧卧位动态CT脊髓造影联合实时团注跟踪(dCTM-BT)检测脑脊液-静脉瘘(CVF)。48%患者检出CVF,Bern评分高者检出率100%,中等者14%,低者0%;ROC曲线下面积0.99,最佳截断值为Bern评分≥5分(敏感度96%,特异度100%)。

要点

  • Bern评分≥5分时dCTM-BT检出CVF的敏感度96%、特异度100%,曲线下面积0.99。
  • CVF多见于T6-12(18/23),70%位于右侧,T1-5仅4例、L1仅1例。
  • 高Bern评分者CVF检出率100%(22/22),中等者14%(1/7),低者0%(0/19)。

核心结论

  • dCTM-BT技术可行,对CVF的识别和定位具有极佳诊断效能;Bern评分与CVF检出强相关,可能有助于筛选适合接受dCTM-BT的患者。

研究设计与样本

  • 回顾性研究,纳入48例疑似自发性颅内低压且脊柱MRI无硬膜外积液的患者,均接受dCTM-BT检查。

关键影像表现/征象

  • CVF位于T1-5者4例、T6-12者18例、L1者1例,70%位于右侧。
  • 48例中23例(48%)经dCTM-BT检出CVF。

诊断标准与关键数值

  • Bern评分高者CVF检出22/22(100%),中等者1/7(14%),低者0/19(0%)。
  • ROC曲线下面积0.99(95%CI 0.98-1.00),最佳截断值为Bern评分≥5分,敏感度96%、特异度100%。

临床应用与阅片要点

  • 在胸上段水平进行CT团注监测,见致密鞘内对比剂后至少采集3次脊柱CTM图像。
  • 由2名神经放射科医生阅片评估CVF。
  • 根据脑MRI计算Bern评分,评分≥5分者CVF检出率最高。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: CSF-venous fistulas (CVFs) associated with spontaneous intracranial hypotension (SIH) may have a transient appearance, relative to contrast arrival, which may influence the diagnostic performance of lateral decubitus CT myelography (CTM). We developed a dynamic CTM protocol using real-time bolus-tracking (dCTM-BT) to improve the temporal resolution and standardize the timing of CTM acquisitions post-intrathecal contrast administration. The purpose of our study was to evaluate the feasibility of the dCTM-BT technique and evaluate its diagnostic yield for CVF detection, stratified by brain MRI SIH findings.

MATERIALS AND METHODS: Patients with suspected SIH without extradural fluid collection on spine MRI who underwent dCTM-BT were retrospectively reviewed. CT bolus monitoring was performed at the upper thoracic level. Following the visualization of dense intrathecal contrast, at least 3 CTM acquisitions of the spine were obtained and reviewed by 2 neuroradiologists. The Bern SIH score was calculated on the brain MRI. The diagnostic yield for CVF detection was evaluated, stratified by Bern score categories and a receiver operating characteristic (ROC) analysis.

RESULTS: Out of 48 patients, 23 (48%) had a CVF on dCTM-BT, located at T1-5 (n = 4), T6-12 (n = 18), L1 (n = 1), with 70% on the right. CVF was identified in 22/22 (100%) of patients who had a high Bern score, 1/7 (14%) of those who had an intermediate score, and 0/19 (0%) of those who had a low score. The area under the ROC curve was 0.99 (95% CI, 0.98-1.00). The optimal cutoff was a Bern score of ≥5 (96% sensitivity, 100% specificity).

CONCLUSIONS: dCTM-BT is feasible and has excellent diagnostic performance for CVF identification/localization. The Bern score is strongly associated with CVF detection and may help inform who will benefit from dCTM-BT.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Huynh TJ, Parizadeh D, Ahmed AK, et al. Lateral Decubitus Dynamic CT Myelography with Real-Time Bolus Tracking (dCTM-BT) for Evaluation of CSF-Venous Fistulas: Diagnostic Yield Stratified by Brain Imaging Findings. AJNR Am J Neuroradiol. 2023. PMID: 38164531. doi:10.3174/ajnr.A8082

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。