文献速递神经MR

急性缺血性卒中患者DWI-FLAIR不匹配的自动化评估:对常规临床实践的附加价值

Automated Assessment of the DWI-FLAIR Mismatch in Patients with Acute Ischemic Stroke: Added Value to Routine Clinical Practice.
PubMed 文献 · AJNR Am J Neuroradiol · 2024-05-09

本回顾性研究纳入157例急性缺血性卒中患者,评估e-Stroke软件自动分类DWI-FLAIR不匹配的诊断性能,并与2名神经放射学专家比较。软件AUC为0.72,专家AUC为0.76和0.82;使用软件预测作为计算机辅助工具后,专家AUC分别显著提高至0.83和0.89,观察者间一致性κ从0.49提高至0.57。

要点

  • e-Stroke软件自动评估DWI-FLAIR不匹配的AUC为0.72,敏感度90.0%,特异度53.9%。
  • 作为计算机辅助工具,软件使两位专家的AUC分别从0.76和0.82显著提高至0.83和0.89(P < .05)。
  • 软件辅助使观察者间一致性κ从0.49提高至0.57。

核心结论

  • 该自动化定量方法评估DWI-FLAIR不匹配的结果与人类专家相当,并能提高专家神经放射科医生判断DWI-FLAIR状态的诊断准确性。

研究设计与样本

  • 回顾性研究,纳入157例有MR成像且卒中发作时间已知的急性缺血性卒中患者;由2名对发作时间不知情的神经放射科医生评估DWI-FLAIR不匹配,并由e-Stroke软件自动评估;4周后神经放射科医生在软件预测结果辅助下重新评估。

诊断标准与关键数值

  • e-Stroke软件判断DWI-FLAIR不匹配的AUC/敏感度/特异度为0.72/90.0/53.9;神经放射科医生1为0.76/69.1/84.2,医生2为0.82/91.4/73.7;使用e-Stroke预测辅助后分别提高至0.83/79.0/86.8和0.89/92.6/85.5(P < .05);观察者间一致性κ从0.49提高至0.57。

临床应用与阅片要点

  • 作者结论认为该自动化定量方法评估DWI-FLAIR不匹配的结果与人类专家相当,并能提高专家神经放射科医生判断DWI-FLAIR状态的诊断准确性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: The DWI-FLAIR mismatch is used to determine thrombolytic eligibility in patients with acute ischemic stroke when the time since stroke onset is unknown. Commercial software packages have been developed for automated DWI-FLAIR classification. We aimed to use e-Stroke software for automated classification of the DWI-FLAIR mismatch in a cohort of patients with acute ischemic stroke and in a comparative analysis with 2 expert neuroradiologists.

MATERIALS AND METHODS: In this retrospective study, patients with acute ischemic stroke who had MR imaging and known time since stroke onset were included. The DWI-FLAIR mismatch was evaluated by 2 neuroradiologists blinded to the time since stroke onset and automatically by the e-Stroke software. After 4 weeks, the neuroradiologists re-evaluated the MR images, this time equipped with automated predicted e-Stroke results as a computer-assisted tool. Diagnostic performances of e-Stroke software and the neuroradiologists were evaluated for prediction of DWI-FLAIR mismatch status.

RESULTS: A total of 157 patients met the inclusion criteria. A total of 82 patients (52%) had a time since stroke onset of ≤4.5 hours. By means of consensus reads, 81 patients (51.5%) had a DWI-FLAIR mismatch. The diagnostic accuracy (area under the curve/sensitivity/specificity) of e-Stroke software for the determination of the DWI-FLAIR mismatch was 0.72/90.0/53.9. The diagnostic accuracy (area under the curve/sensitivity/specificity) for neuroradiologists 1 and 2 was 0.76/69.1/84.2 and 0.82/91.4/73.7, respectively; both significantly (P < .05) improved to 0.83/79.0/86.8 and 0.89/92.6/85.5, respectively, following the use of e-Stroke predictions as a computer-assisted tool. The interrater agreement (κ) for determination of DWI-FLAIR status was improved from 0.49 to 0.57 following the use of the computer-assisted tool.

CONCLUSIONS: This automated quantitative approach for DWI-FLAIR mismatch provides results comparable with those of human experts and can improve the diagnostic accuracies of expert neuroradiologists in the determination of DWI-FLAIR status.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Tavakkol E, Kihira S, McArthur M, et al. Automated Assessment of the DWI-FLAIR Mismatch in Patients with Acute Ischemic Stroke: Added Value to Routine Clinical Practice. AJNR Am J Neuroradiol. 2024. PMID: 38290738. doi:10.3174/ajnr.A8170

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。