文献速递头颈MR

反向编码方向畸变校正的扩散加权成像:在体外和体内研究中提高图像质量及畸变校正以准确评估ADC

Diffusion weighted imaging with reverse encoding distortion correction: Improvement of image quality and distortion for accurate ADC evaluation in in vitro and in vivo studies.
PubMed 文献 · Eur J Radiol · 2024-01-06

本研究纳入48例头颈部肿瘤患者,行有无反向编码方向(RDC)的DWI及病理检查,比较两组图像变形率、ADC值及诊断性能。结果显示RDC可显著减小DWI变形率(p<0.0001),但两种DWI诊断准确率无显著差异(p>0.05)。结论认为RDC可改善DWI图像质量和畸变,可能有助于更准确评估ADC及鉴别头颈部良恶性肿瘤。

要点

  • RDC可显著减小头颈部DWI与T2WI之间的变形率(p<0.0001)。
  • 有无RDC的DWI在恶性与良性肿瘤间ADC值均有显著差异(p<0.05)。
  • 两种DWI诊断准确率无显著差异(p>0.05)。

核心结论

  • RDC可改善DWI图像质量和畸变,可能有助于更准确评估ADC及鉴别头颈部良恶性肿瘤。

研究设计与样本

  • 体内研究纳入48例头颈部肿瘤患者,行有无RDC的DWI及病理检查,肿瘤分为恶性组(n=21)和良性组(n=27)。

关键影像表现/征象

  • RDC的DWI变形率显著小于无RDC的DWI(p<0.0001)。

诊断标准与关键数值

  • 恶性 vs 良性肿瘤ADC值在每种DWI上均有显著差异(p<0.05)。
  • 有无RDC的DWI诊断准确率无显著差异(p>0.05)。

临床应用与阅片要点

  • RDC可减小DWI变形率,可能有助于更准确评估头颈部肿瘤ADC。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: The purpose of this in vivo study was to determine the effect of reverse encoding direction (RDC) on apparent diffusion coefficient (ADC) measurements and its efficacy for improving image quality and diagnostic performance for differentiating malignant from benign tumors on head and neck diffusion-weighted imaging (DWI).

METHODS: Forty-eight patients with head and neck tumors underwent DWI with and without RDC and pathological examinations. Their tumors were then divided into two groups: malignant (n = 21) and benign (n = 27). To determine the utility of RDC for DWI, the difference in the deformation ratio (DR) between DWI and T2-weighted images of each tumor was determined for each tumor area. To compare ADC measurement accuracy of DWIs with and without RDC for each patient, ADC values for tumors and spinal cord were determined by using ROI measurements. To compare DR and ADC between two methods, Student's t-tests were performed. Then, ADC values were compared between malignant and benign tumors by Student's t-test on each DWI. Finally, sensitivity, specificity and accuracy were compared by means of McNemar's test.

RESULTS: DR of DWI with RDC was significantly smaller than that without RDC (p < 0.0001). There were significant differences in ADC between malignant and benign lesions on each DWI (p < 0.05). However, there were no significant difference of diagnostic accuracy between the two DWIs (p > 0.05).

CONCLUSION: RDC can improve image quality and distortion of DWI and may have potential for more accurate ADC evaluation and differentiation of malignant from benign head and neck tumors.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Furuta M, Ikeda H, Hanamatsu S, et al. Diffusion weighted imaging with reverse encoding distortion correction: Improvement of image quality and distortion for accurate ADC evaluation in in vitro and in vivo studies. Eur J Radiol. 2024. PMID: 38237523. doi:10.1016/j.ejrad.2024.111289

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。