文献速递神经介入CTDSA

血管内治疗后即刻平板灌注成像的价值(AFTERMATH):一项概念验证研究

Value of Immediate Flat Panel Perfusion Imaging after Endovascular Therapy (AFTERMATH): A Proof of Concept Study.
PubMed 文献 · AJNR Am J Neuroradiol · 2024-02-07

单中心分析2019年6月至2021年3月连续收治的26例接受机械取栓并术后即刻行平板CT灌注成像(FPCT-PI)的急性卒中患者。以DSA的TICI分级为参考,FPCT-PI与DSA在21/26例中关于低灌注有无的判断一致;FPCT-PI可能补充评估再灌注疗效,并可能为血管造影室内的决策提供信息。

要点

  • 术后即刻FPCT-PI与DSA在21/26例中关于低灌注有无的判断一致。
  • FPCT-PI可在全部10/26例术者误判为TICI 3的假阳性病例中避免TICI高估。
  • FPCT-PI可能补充评估再灌注疗效,并可能为血管造影室内决策提供信息。

核心结论

  • FPCT-PI可能在相当比例接受机械取栓的患者中提供额外的临床相关信息。
  • 因此,FPCT-PI可能补充再灌注疗效的评估,并可能为血管造影室内的决策提供信息。

研究设计与样本

  • 单中心分析,连续纳入2019年6月至2021年3月间接受机械取栓及术后FPCT-PI的急性卒中患者26例。
  • 由对技术细节和临床数据设盲的核心实验室在术后DSA图像上行TICI分级,并在时间敏感的FPCT-PI图上定性评估再灌注。

关键影像表现/征象

  • 根据DSA与FPCT-PI的一致性将患者分为4组:低灌注表现位置完全匹配(组1)、低灌注表现位置不匹配(组2)、DSA完全再灌注而FPCT-PI示低灌注(组3)、DSA示低灌注而FPCT-PI示完全再灌注(组4)。

诊断标准与关键数值

  • 低灌注(有/无)判断在21/26例中一致;其中16例(组1)再灌注表现在位置和大小上完全一致,5例(组2)位置不匹配。
  • 低灌注有无判断不一致的5例中,3例归入组3,2例归入组4。
  • FPCT-PI可在全部术者误判为TICI 3的假阳性病例(10/26)中避免TICI高估。

临床应用与阅片要点

  • FPCT-PI可能在相当比例接受机械取栓的患者中提供额外的临床相关信息。
  • FPCT-PI可能补充再灌注疗效的评估,并可能为血管造影室内的决策提供信息。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Potential utility of flat panel CT perfusion imaging (FPCT-PI) performed immediately after mechanical thrombectomy (MT) is unknown. We aimed to assess whether FPCT-PI obtained directly post-MT could provide additional potentially relevant information on tissue reperfusion status.

MATERIALS AND METHODS: This was a single-center analysis of all patients with consecutive acute stroke admitted between June 2019 and March 2021 who underwent MT and postinterventional FPCT-PI (n = 26). A core lab blinded to technical details and clinical data performed TICI grading on postinterventional DSA images and qualitatively assessed reperfusion on time-sensitive FPCT-PI maps. According to agreement between DSA and FPCT-PI, all patients were classified into 4 groups: hypoperfusion findings perfectly matched by location (group 1), hypoperfusion findings mismatched by location (group 2), complete reperfusion on DSA with hypoperfusion on FPCT-PI (group 3), and hypoperfusion on DSA with complete reperfusion on FPCT-PI (group 4).

RESULTS: Detection of hypoperfusion (present/absent) concurred in 21/26 patients. Of these, reperfusion findings showed perfect agreement on location and size in 16 patients (group 1), while in 5 patients there was a mismatch by location (group 2). Of the remaining 5 patients with disagreement regarding the presence or absence of hypoperfusion, 3 were classified into group 3 and 2 into group 4. FPCT-PI findings could have avoided TICI overestimation in all false-positive operator-rated TICI 3 cases (10/26).

CONCLUSIONS: FPCT-PI may provide additional clinically relevant information in a considerable proportion of patients undergoing MT. Hence, FPCT-PI may complement the evaluation of reperfusion efficacy and potentially inform decision-making in the angiography suite.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Mujanovic A, Kurmann CC, Manhart M, et al. Value of Immediate Flat Panel Perfusion Imaging after Endovascular Therapy (AFTERMATH): A Proof of Concept Study. AJNR Am J Neuroradiol. 2024. PMID: 38238089. doi:10.3174/ajnr.A8103

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。