指南与共识神经儿科影像MR

成人及儿童脑肿瘤与癫痫患者术前语言、运动及视觉区定位的静息态fMRI采集与预处理推荐步骤

Recommended Resting-State fMRI Acquisition and Preprocessing Steps for Preoperative Mapping of Language and Motor and Visual Areas in Adult and Pediatric Patients with Brain Tumors and Epilepsy.
PubMed 文献 · AJNR Am J Neuroradiol · 2024-02-07

美国功能神经放射学会、美国儿科神经放射学会和美国神经放射学会功能与扩散MR成像研究组基于广泛文献复习和专家共识,推荐了成人及儿童脑肿瘤与癫痫患者术前语言、运动及视觉区定位的静息态fMRI采集参数与预处理步骤,以促进标准化和多中心协作。

要点

  • 推荐静息态fMRI采集时间至少6分钟、睁眼注视、在任务态fMRI和对比剂给药前扫描。
  • 推荐时间分辨率≤2秒、扫描仪场强3T或更高。
  • 推荐预处理包括头动校正、去尖峰、体积删减、CSF和白质信号回归、头动回归、带通滤波及空间平滑。

核心结论

  • 共识推荐用于静息态fMRI采集和预处理的步骤将有助于标准化实践并指导各机构开展静息态fMRI项目。

研究设计与样本

  • 由多个机构组成的fMRI专家组基于广泛文献复习和专家共识提出推荐,针对成人及儿童脑肿瘤和癫痫患者语言、运动及视觉区定位。

诊断标准与关键数值

  • 推荐采集时间至少6分钟;睁眼注视扫描;在任务态fMRI和对比剂给药前获取静息态fMRI;时间分辨率≤2秒;扫描仪场强3T或更高。
  • 推荐预处理步骤和参数:头动校正(基于种子相关分析[SBC]、独立成分分析[ICA]);去尖峰(SBC);体积删减(SBC、ICA);脑脊液和白质信号的干扰回归(SBC);头动回归(SBC、ICA);带通滤波(SBC、ICA);空间平滑核大小为有效体素大小的两倍(SBC、ICA)。

临床应用与阅片要点

  • 推荐静息态fMRI采集时间至少6分钟、睁眼注视、在任务态fMRI和对比剂给药前扫描。
  • 推荐时间分辨率≤2秒、扫描仪场强3T或更高。
  • 推荐预处理包括头动校正、去尖峰、体积删减、CSF和白质信号回归、头动回归、带通滤波及空间平滑。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Resting-state (rs) fMRI has been shown to be useful for preoperative mapping of functional areas in patients with brain tumors and epilepsy. However, its lack of standardization limits its widespread use and hinders multicenter collaboration. The American Society of Functional Neuroradiology, American Society of Pediatric Neuroradiology, and the American Society of Neuroradiology Functional and Diffusion MR Imaging Study Group recommend specific rs-fMRI acquisition approaches and preprocessing steps that will further support rs-fMRI for future clinical use. A task force with expertise in fMRI from multiple institutions provided recommendations on the rs-fMRI steps needed for mapping of language, motor, and visual areas in adult and pediatric patients with brain tumor and epilepsy. These were based on an extensive literature review and expert consensus.Following rs-fMRI acquisition parameters are recommended: minimum 6-minute acquisition time; scan with eyes open with fixation; obtain rs-fMRI before both task-based fMRI and contrast administration; temporal resolution of ≤2 seconds; scanner field strength of 3T or higher. The following rs-fMRI preprocessing steps and parameters are recommended: motion correction (seed-based correlation analysis [SBC], independent component analysis [ICA]); despiking (SBC); volume censoring (SBC, ICA); nuisance regression of CSF and white matter signals (SBC); head motion regression (SBC, ICA); bandpass filtering (SBC, ICA); and spatial smoothing with a kernel size that is twice the effective voxel size (SBC, ICA).The consensus recommendations put forth for rs-fMRI acquisition and preprocessing steps will aid in standardization of practice and guide rs-fMRI program development across institutions. Standardized rs-fMRI protocols and processing pipelines are essential for multicenter trials and to implement rs-fMRI as part of standard clinical practice.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Kumar VA, Lee J, Liu HL, et al. Recommended Resting-State fMRI Acquisition and Preprocessing Steps for Preoperative Mapping of Language and Motor and Visual Areas in Adult and Pediatric Patients with Brain Tumors and Epilepsy. AJNR Am J Neuroradiol. 2024. PMID: 38164572. doi:10.3174/ajnr.A8067

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。