文献速递神经头颈MR

亚急性视神经炎中视交叉手动与自动测量的OCT及MRI相关性研究

Optic chiasm manual and automated measurements in sub-acute optic neuritis with OCT and MRI correlations.
PubMed 文献 · Eur J Radiol · 2024-01-26

本研究在43例亚急性视神经炎、20例无视神经炎的多发性硬化患者和20名健康受试者中,比较了两种既往报道的视交叉手动测量方法与新提出的简化方法「视交叉平均面积(OCMA)」的可重复性,并分析OCMA分数与OCT参数及FreeSurfer自动分割的关联。OCMA在组内和组间信度分析中均表现更优,具有优良的ICC和DSC(掩模重叠超过80%),且OCMA分数在各组中均与FreeSurfer获得的视交叉体积分数相关。

要点

  • 新提出的OCMA测量法在组内与组间信度上均优于两种既往方法,ICC与DSC优良、掩模重叠超过80%。
  • OCMA分数(OCMA除以总颅内体积)在各组中均与FreeSurfer自动分割的视交叉体积分数相关。
  • OCMA分数在无视神经炎的多发性硬化患者中与脑实质分数及OCT参数相关。

核心结论

  • OCMA是测量视交叉萎缩的简化方法,信度高于现有方法,并与自动分割方法相关;视交叉衍生指标似乎反映弥漫性神经退行性损害,而在亚急性视神经炎患者中可能与局部损害相关。

研究设计与样本

  • 研究纳入43例亚急性视神经炎、20例无视神经炎的多发性硬化患者和20名健康受试者,复现两种既往报道的视交叉手动测量方法并实施新提出的简化方法OCMA,以ICC和DSC评估组内与组间信度及可重复性,采用偏相关分析OCMA分数与FreeSurfer脑区分割及OCT参数的关联。

诊断标准与关键数值

  • OCMA在组内和组间信度分析中均表现更优,ICC优良、DSC优良,掩模重叠超过80%。
  • OCMA分数在各组中均与FreeSurfer获得的视交叉体积分数相关。
  • OCMA分数在无视神经炎的多发性硬化患者中与脑实质分数及OCT参数相关。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: The optic chiasm (OC) is a central structure in the visual pathway and can be visualized in conventional MRI, but no consensus regarding its measurement has been defined. We aim to investigate the most reproducible manual approach to OC measurement and to explore associations of OC with optical coherence tomography (OCT) parameters, and automatic brain segmentation (FreeSurfer) in subacute optic neuritis (sON), multiple sclerosis without optic neuritis (MSwoON), and healthy subjects (HS).

MATERIALS AND METHODS: We reproduced two previously reported methodologies and implemented a new proposed simplified approach, entitled optic chiasm mean area (OCMA). The intra and inter-rater reliability and reproducibility were assessed through the intraclass correlation (ICC) and Dice similarity (DSC) coefficients. Partial correlations were calculated to gauge the associations between OCMA fraction (OCMA divided by total intracranial volume), brain regional segmentations derived from FreeSurfer, and OCT parameters.

RESULTS: We have analysed 43 sON, 20 MSwoON, and 20 HS. OCMA presented better results for reliability in both intra- and inter-rater analysis (excellent ICC and DSC with over 80% overlap between masks), as compared to the other two approaches. OCMA fraction was associated with OC volume fraction obtained with Freesurfer in all groups, brain parenchymal fraction, and OCT parameters in MSwoON.

CONCLUSIONS: The OCMA is a simplified approach to measure OC atrophy, has a higher reliability than the current approaches and shows association with an automated method. OC-derived measures seem to reflect diffuse neurodegenerative damage, whereas, in patients with subacute ON, it may be associated with local damage.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Braga N, Pareto D, Mongay-Ochoa N, et al. Optic chiasm manual and automated measurements in sub-acute optic neuritis with OCT and MRI correlations. Eur J Radiol. 2024. PMID: 38290202. doi:10.1016/j.ejrad.2024.111332

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。