文献速递神经外周血管介入DSA

Leo plus支架血管内重建治疗高位颈段长节段颈动脉夹层

Endovascular reconstruction of high cervical and long-segment carotid artery dissections with Leo plus stent.
PubMed 文献 · Neuroradiology · 2024-01-08

Leo plus支架治疗高位颈段长节段颈动脉夹层的长期观察显示该方式实用、安全、有效,Leo Plus支架似乎是处理此类夹层的合适选择。

要点

  • 高位颈段长节段颈动脉夹层(平均长度5.7 cm、狭窄92.3%)可用Leo plus支架行血管内重建。
  • 17例中15例置入单枚Leo plus支架,2例另用Wallstent颈动脉支架,均成功到位。
  • 中位随访29个月无缺血性卒中,除1枚Leo plus支架外均通畅,7个假性动脉瘤均消失。

核心结论

  • Leo plus支架治疗高位颈段长节段颈动脉夹层的长期观察显示该方式实用、安全、有效,Leo Plus支架似乎是处理此类夹层的合适选择。

研究设计与样本

  • 回顾性综述,纳入17例高位颈段长节段颈动脉夹层患者(平均年龄48.1岁)共17处夹层,均使用Leo plus支架行血管内重建,分析人口学、临床表现、操作特征、并发症及随访结果。

关键影像表现/征象

  • 7处夹层合并假性动脉瘤,平均夹层长度5.7 cm,平均狭窄程度92.3%。
  • 15例置入单枚Leo plus支架,2例另使用Wallstent颈动脉支架,所有支架均成功置入预定位置。
  • 平均残余狭窄程度22.2%,围手术期无并发症。

诊断标准与关键数值

  • 中位随访29个月,无缺血性卒中事件发生。
  • 随访期间除1枚Leo plus支架外其余均保持通畅。
  • 末次影像学评估时7个假性动脉瘤全部消失。

临床应用与阅片要点

  • 作者经验表明Leo plus支架治疗高位颈段长节段颈动脉夹层实用、安全、有效,Leo Plus支架似乎是此类夹层的合适选择。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Endovascular reconstruction has emerged as a viable alternative for carotid artery dissections (CADs) that are unresponsive to antithrombotic therapy. However, high cervical and long-segment CADs pose challenges during endovascular treatment due to their distal location and tortuous anatomy. We presented our experiences using endovascular reconstruction with the Leo plus stent for this type of CAD.

METHODS: We conducted a retrospective review of patients with high cervical and long-segment CADs treated using the Leo plus stent. We analyzed patient demographics, clinical presentations, procedural features, complications, and follow-up outcomes.

RESULTS: A total of 17 patients (mean age, 48.1 years) with 17 CADs were identified. Seven of these dissections were accompanied by pseudoaneurysm. The mean length of the dissection was 5.7 cm, and the mean degree of stenosis was 92.3%. A single Leo plus stent was deployed in 15 patients, while another Wallstent carotid stent was used in 2 cases. All stents were successfully positioned in their intended sites. The average degree of residual stenosis was 22.2%. There were no perioperative complications. With a median follow-up duration of 29 months, no ischemic stroke events occurred. All but one Leo plus stent remained patent during follow-up, and all 7 pseudoaneurysms had disappeared at the last radiological assessment.

CONCLUSION: Our experience in treating high cervical and long-segment CADs with the Leo plus stent demonstrates that this approach is practical, safe, and effective, as evidenced by long-term observations. The Leo Plus stent appears to be a suitable option for managing this type of CAD.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. Lu GD, Yang W, Jia ZY, et al. Endovascular reconstruction of high cervical and long-segment carotid artery dissections with Leo plus stent. Neuroradiology. 2024. PMID: 38191867. doi:10.1007/s00234-023-03274-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。