文献速递骨肌儿科影像介入US

超声用于监测儿童肱骨髁上骨折复位及尺神经半脱位

The use of ultrasound for monitoring reduction and ulnar nerve subluxation in pediatric humeral supracondylar fractures.
PubMed 文献 · Eur J Radiol · 2023-11-14

本研究评估无辐射超声引导闭合复位及内侧穿针时实时监测尺神经动态的可行性,对比传统透视引导交叉穿针技术。超声组30例在复位精度、活动范围、Baumann角与肱尺角恢复及畸形愈合率上均优于传统组40例,且无尺神经损伤,而传统组损伤率为2.5%。超声测量骨折移位与透视相当(组内相关系数>0.90),并发现肘关节屈曲120°时53.3%患者出现尺神经前脱位。

要点

  • 超声引导复位可提高儿童肱骨髁上骨折复位精度并减少畸形愈合。
  • 超声测量骨折移位与透视高度一致(组内相关系数>0.90)。
  • 实时超声可监测尺神经动态,屈肘120°时53.3%出现尺神经前脱位。

核心结论

  • 超声评估骨折复位与透视同样可靠;术中超声可显著提高复位精度和影像学结果,并降低尺神经损伤风险。

研究设计与样本

  • 研究纳入70例急性移位肱骨髁上骨折儿童,超声组30例接受超声引导复位,传统组40例接受透视引导复位,两组均行经皮交叉穿针及石膏固定,术后随访6个月比较结局。

关键影像表现/征象

  • 超声组复位精度提高、活动范围增加、Baumann角与肱尺角恢复更优、畸形愈合发生率降低(均p<0.05)。
  • 超声组无尺神经损伤,传统组尺神经损伤发生率为2.5%。
  • 超声组实时监测显示尺神经活动度过大,肘关节屈曲120°时53.3%患者出现尺神经前脱位,90°时40%,60°时16.7%,30°时无。

诊断标准与关键数值

  • 超声测量骨折移位与透视测量的组内相关系数>0.90。
  • 尺神经前脱位评估以肘关节屈曲角度为条件:120°时53.3%、90°时40%、60°时16.7%、30°时无。

临床应用与阅片要点

  • 术中超声可用于引导儿童肱骨髁上骨折闭合复位并评估复位效果。
  • 内侧穿针时实时超声可监测尺神经动态,注意屈肘120°时尺神经前脱位发生率高。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Traditional treatment for displaced humeral supracondylar fractures (SCFs) in children involves closed reduction (CR) under fluoroscopic guidance, percutaneous pinning, and immobilization with a long-arm cast. This study aims to explore the viability of using radiation-free ultrasound (US) for guiding CR and tracking ulnar nerve dynamics during medial pinning, contrasting the US method with the conventional cross pinning technique.

MATERIALS AND METHODS: We assessed 70 children with acute displaced SCFs. The US group (n = 30) underwent US-guided reduction, whereas the traditional group (n = 40) underwent fluoroscopy-guided reduction. Both groups received percutaneous cross pinning and subsequent cast immobilization. Postoperative outcomes were compared between the two methods after a 6-month follow-up. In the US group, ultrasonography assessed fracture displacement distances before and after CR. The angle at which the ulnar nerve relocated to the cubital tunnel during elbow extension was documented using real-time US monitoring during medial pinning.

RESULTS: The US group demonstrated improved reduction accuracy, increased range of motion, superior restoration of both Baumann and Humeroulnar angles, and a decreased incidence of malunions compared to the traditional group (all p < 0.05). The ultrasonographic measurement of fracture displacement was comparable with that of fluoroscopy (intraclass correlation coefficient > 0.90). In the US group, no ulnar nerve injury was noted, compared to 2.5 % in the traditional group, and real-time US observations revealed ulnar nerve hypermobility, with 53.3 % of patients exhibiting anterior ulnar nerve subluxation at 120° elbow flexion, 40 % at 90°, 16.7 % at 60°, and none at 30° flexion.

CONCLUSION: Ultrasound is as reliable as fluoroscopy for evaluating fracture reductions. The use of intra-operative ultrasound significantly improves reduction accuracy and radiographic outcomes while reducing the risk of ulnar nerve injury.

来源:Eur J Radiol,查看原文。版权归原作者所有。