低剂量碘对比剂与辐射用于头颈部双层光谱探测器CT血管成像虚拟单能成像的前瞻性随机研究
前瞻性随机纳入280例连续行头颈部双层光谱探测器CT血管成像的患者,分四组比较不同剂量指数与碘对比剂方案。B组55 keV虚拟单能成像图像质量等于或优于A组常规图像,D组有效剂量、碘负荷和碘流率分别较A组降低44%、59%和19%。
要点
- 双层光谱探测器CT头颈部CTA中,55 keV虚拟单能成像可在低对比剂和低辐射剂量下获得等于或优于常规图像的质量。
- D组(碘海醇300 mgI/mL、0.4 mL/kg、DRI 26)与B组图像信噪比、对比噪声比及主观评分相似(P>0.05)。
- D组较A组有效剂量降低44%、碘负荷降低59%、碘流率降低19%。
核心结论
- 双层光谱探测器CT头颈部CTA采用55 keV虚拟单能成像,低剂量碘对比剂和辐射可提供等于或优于常规扫描方案的图像质量。
研究设计与样本
- 前瞻性随机研究,连续纳入280例行头颈部双层光谱探测器CT血管成像的患者,随机分为四组(A组DRI 31、碘普罗胺370 mgI/mL、0.8 mL/kg;B组DRI 26、碘普罗胺370 mgI/mL、0.4 mL/kg;C组DRI 26、碘佛醇320 mgI/mL、0.4 mL/kg;D组DRI 26、碘海醇300 mgI/mL、0.4 mL/kg)。
关键影像表现/征象
- B组55 keV虚拟单能成像为最佳keV,其客观和主观图像质量等于或优于A组常规图像。
- D组信噪比、对比噪声比和主观图像质量与B组相似(P>0.05)。
- D组有效剂量、碘负荷和碘流率较A组分别降低44%、59%和19%。
诊断标准与关键数值
- 主观图像质量采用5点Likert量表评估。
- 客观图像质量评估指标包括血管衰减、图像噪声、信噪比和对比噪声比。
临床应用与阅片要点
- 头颈部CTA采用双层光谱探测器CT时,可重建50-70 keV虚拟单能图像,B组中55 keV为最佳keV。
- 低剂量方案(DRI 26、碘海醇300 mgI/mL、0.4 mL/kg)联合55 keV虚拟单能成像可获得与常规方案相当的图像质量。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: To investigate the feasibility of virtual monochromatic imaging (VMI) of dual-layer spectral detector computed tomography (SDCT) to reduce iodinated contrast material (CM) and radiation dose in craniocervical computed tomography angiography (CTA).
MATERIALS AND METHODS: A total of 280 consecutively selected patients performed craniocervical CTA with SDCT were prospectively selected and randomly divided into four groups (A, DoseRight index (DRI) 31, iopromide 370mgI/mL, volume 0.8 mL/kg; B, DRI 26, iopromide 370mgI/mL, volume 0.4 mL/kg; C, DRI 26, ioversol 320mgI/mL, volume 0.4 mL/kg; D, DRI 26, iohexol 300mgI/mL, volume 0.4 mL/kg). 50-70 kiloelectron volts (keV) VMIs in group B were reconstructed and compared to group A to select the optimal keV. Then, the optimal keV in groups B, C and D was reconstructed and compared. Objective image quality, including vascular attenuation, image noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), was evaluated. Subjective image quality was assessed using a 5-point Likert scale. In addition, the effective dose (ED), iodine load and iodine delivery rate (IDR) were compared between groups A and D.
RESULTS: 55 keV VMI was the optimal VMI in group B. The objective and subjective image quality of 55 keV VMI in group B were equal to or better than those of the CI in group A. The SNR, CNR and subjective image quality in group D were similar to those in group B (P > 0.05). The ED, iodine load and IDR of group D were reduced by 44%, 59% and 19%, respectively, when compared to those of group A.
CONCLUSION: Low dose iodinated CM and radiation for 55 keV VMI in craniocervical CTA using SDCT could still provide equivalent or better image quality than the conventional scanning protocol.
引用
- Zhou X, Cui M, Liu Y, et al. Low Dose Iodinated Contrast Material and Radiation for Virtual Monochromatic Imaging in Craniocervical Dual-Layer Spectral Detector Computed Tomography Angiography: A Prospective and Randomized Study. Acad Radiol. 2023. PMID: 38135625. doi:10.1016/j.acra.2023.12.004
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。