纳入100例50岁以上同时接受腰椎CT与双能X线吸收检测的患者,比较冠状面、轴位及矢状面CT值诊断骨质疏松的效能。冠状面AUC为0.80,与轴位0.78、矢状面0.78无显著差异,冠状面与轴位及矢状面ICC分别为0.95和0.93。结论认为三个平面可互换用于CT骨密度测量。

要点

  • 冠状面CT值诊断骨质疏松的AUC为0.80,与轴位0.78、矢状面0.78无显著差异。
  • 冠状面与轴位ICC为0.95,与矢状面ICC为0.93,一致性极好。
  • 冠状面、轴位、矢状面最佳截断值分别为110、112、112 HU。

核心结论

  • 冠状面在机会性骨质疏松筛查中与轴位及矢状面诊断效能无显著差异,三个平面可互换用于CT骨密度测量。

研究设计与样本

  • 共纳入100例年龄≥50岁、3个月内接受腰椎CT和双能X线吸收检测的患者;以双能X线吸收检测结果诊断骨质疏松;在椎体中心测量冠状面、轴位和矢状面CT值。

关键影像表现/征象

  • 在椎体中心测量CT值,分别于冠状面、轴位和矢状面进行。

诊断标准与关键数值

  • 冠状面诊断骨质疏松的AUC为0.80(95%CI 0.71-0.89),与轴位AUC 0.78(95%CI 0.68-0.87;P=0.39)无显著差异。
  • 冠状面AUC 0.80(95%CI 0.71-0.89)与矢状面AUC 0.78(95%CI 0.69-0.87;P=0.68)无显著差异。
  • 冠状面与轴位ICC为0.95(95%CI 0.92-0.96),冠状面与矢状面ICC为0.93(95%CI 0.85-0.96)。
  • 冠状面、轴位、矢状面的最佳截断值分别为110、112、112 HU。

临床应用与阅片要点

  • 冠状面与轴位及矢状面可互换用于CT骨密度测量。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To compare the coronal plane with axial and sagittal planes in opportunistic screening of osteoporosis using computed tomography (CT).

MATERIALS AND METHODS: A total of 100 patients aged ≥ 50 years who underwent both lumbar spine CT and dual-energy X-ray absorptiometry within 3 months were included. Osteoporosis was diagnosed based on dual-energy X-ray absorptiometry results. The CT number was measured at the center of the vertebral body in coronal, axial, and sagittal planes. To compare the coronal plane with axial and sagittal planes in diagnosing osteoporosis, the areas under the receiver operating characteristic curve (AUC) were compared and intraclass correlation coefficient (ICC) was calculated. The optimal cutoff values were calculated using Youden's index.

RESULTS: The AUC of the coronal plane (0.80; 95% confidence interval [CI], 0.71-0.89) was not significantly different from that of the axial plane (0.78; 95% CI, 0.68-0.87; P = 0.39) and that of the sagittal plane (0.78; 95% CI, 0.69-0.87; P = 0.68). Excellent concordance rates were observed between coronal and axial planes with ICC of 0.95 (95% CI, 0.92-0.96) and between coronal and sagittal planes with ICC of 0.93 (95% CI, 0.85-0.96). The optimal cutoff values for the coronal, axial, and sagittal planes were 110, 112, and 112 HU, respectively.

CONCLUSION: The coronal plane does not significantly differ from axial and sagittal planes in opportunistic screening of osteoporosis. Thus, the coronal plane as well as axial and sagittal planes can be used interchangeably in measuring bone mineral density using CT.

来源:Skeletal Radiol,查看原文。版权归原作者所有。

引用

  1. Kim Y, Kim C, Lee E, et al. Coronal plane in opportunistic screening of osteoporosis using computed tomography: comparison with axial and sagittal planes. Skeletal Radiol. 2023. PMID: 38055040. doi:10.1007/s00256-023-04525-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。