在健康肌腱和肌腱病患者中,测量跟腱止点超声厚度比测量中段可靠性更低
研究纳入50例跟腱病患者和50例无症状个体,用超声组织特征(UTC)测量跟腱中段和止点最大厚度,评估组内与组间信度。跟腱病组组间ICC为0.93、组内为0.95,无症状组分别为0.91和0.94;中段组间ICC为0.97、组内为0.98,止点组间ICC为0.79、组内为0.89;止点测量信度显著低于中段。
要点
- 跟腱中段厚度测量的组间与组内信度均为「优秀」(ICC 0.97和0.98)。
- 跟腱止点厚度测量的组间信度为「中等至良好」(ICC 0.79),组内信度为「良好」(ICC 0.89)。
- 止点区域厚度测量的ICC显著低于中段区域。
核心结论
- 在跟腱病患者中,超声测量跟腱中段厚度的信度为「优秀」,测量止点区域的信度为「良好」;与中段相比,止点区域厚度测量的ICC显著更低。
研究设计与样本
- 纳入50例跟腱病患者和50例无症状个体,采用常规超声和标准化超声组织特征(UTC)流程测量跟腱中段和止点区域的最大厚度,用组内相关系数(ICC)评估组间和组内信度。
诊断标准与关键数值
- 跟腱病组组间ICC为0.93(95%CI:0.88-0.96),组内ICC为0.95(95%CI:0.92-0.97)。
- 无症状组组间ICC为0.91(95%CI:0.87-0.94),组内ICC为0.94(95%CI:0.92-0.96)。
- 中段区域组间ICC为0.97(95%CI:0.95-0.98),组内ICC为0.98(95%CI:0.96-0.99)。
- 止点区域组间ICC为0.79(95%CI:0.69-0.87),组内ICC为0.89(95%CI:0.84-0.93)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
INTRODUCTION: Ultrasound is the preferred imaging method in the diagnostic process of Achilles tendinopathy (AT). Ultrasound tissue characterization (UTC) is a frequently used, standardized and valid method to assess tendon geometry in AT patients. It is unknown whether UTC is reliable for measuring Achilles tendon thickness. The aim of the study was to assess intra- and inter-rater reliability of Achilles tendon thickness measurements using UTC in both asymptomatic individuals and patients with AT, and to evaluate if the reliability of thickness measurements differs between the midportion and insertional area.
METHODS: Exactly 50 patients with AT and 50 asymptomatic individuals were included. Using the conventional US and standardized UTC procedure maximum thickness was measured in the midportion and insertion region. To determine inter- and intra-rater reliabilities, the intraclass correlation coefficient (ICC) was used.
RESULTS: The ICC values for inter- and intra-rater reliability were classified as "excellent," for the AT group (0.93 [95% CI: 0.88-0.96] and 0.95 [0.92-0.97]) and asymptomatic participants (0.91 [0.87-0.94] and 0.94 [0.92-0.96]). The reliability of measuring tendon thickness in the midportion region was "excellent," with both inter-rater (0.97 [0.95-0.98]) and intra-rater (0.98 [0.96-0.99]) ICC values indicating high levels of agreement. In the insertional region, ICC values for inter-rater (0.79 [0.69-0.87]) and intra-rater (0.89 [0.84-0.93]) reliability were "moderate to good."
CONCLUSION: We showed excellent reliability for measuring the US thickness of the midportion and good reliability of measuring the insertional region in patients with AT. Significantly lower ICCs were observed for the reliability of thickness measurements in the insertional region when compared with the midportion.