研究纳入2018年10月至2019年12月临床诊断为慢性踝关节外侧不稳(CLAI)的患者60例(60个踝)及健康志愿者35例(70个踝),均行应力超声检查,测量被动中立位(D1)与最大内翻位(D2)的距腓间隙并计算差值ΔD。ΔD为最佳诊断指标,AUC 0.922,最佳截断值0.11 cm,敏感度73%、特异度94%(P < 0.001)。
要点
- 应力超声测量距腓间隙ΔD诊断CLAI的AUC为0.922,最佳截断值0.11 cm
- ΔD最佳截断值下敏感度73%、特异度94%,为所比较参数中最佳诊断指标
- D2的AUC为0.850、D1的AUC为0.635,诊断价值均低于ΔD
核心结论
- 应力超声测量距腓间隙是诊断CLAI的有价值指标,尤其以中立位与应力位之间的差值ΔD为最佳。
研究设计与样本
- 诊断准确性研究,CLAI组60例患者(60个踝),对照组35名健康志愿者(70个踝),两组均行应力超声检查,以ROC曲线和AUC分析评价诊断效能。
关键影像表现/征象
- 常规超声观察距腓前韧带(ATFL)的长度、厚度、松弛、钙化及断裂等特征,并测量被动中立位(D1)与最大内翻位(D2)的距腓间隙。
诊断标准与关键数值
- ΔD(D1-D2)AUC 0.922、最佳截断值0.11 cm、敏感度73%、特异度94%(P < 0.001);D2 AUC 0.850、最佳截断值0.47 cm、敏感度67%、特异度94%(P < 0.001);D1 AUC 0.635、最佳截断值0.47 cm、敏感度67%、特异度94%(P = 0.006)。
临床应用与阅片要点
- 对临床诊断为CLAI的患者,可在应力超声下测量被动中立位与最大内翻位的距腓间隙并计算ΔD,以0.11 cm作为最佳截断值辅助诊断。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To investigate the diagnostic value of measuring the talofibular space using stress sonography for chronic lateral ankle instability (CLAI).
MATERIALS & METHODS: We recruited patients who were clinically diagnosed with CLAI between October 2018 and December 2019 (CLAI group). A control group of healthy volunteers was also included for this study. Both groups underwent a preliminary stress sonographic examination. First, the ultrasonic characteristics of the anterior talofibular ligament (ATFL), including length, thickness, relaxation, calcification, and rupture, were observed using conventional sonography. Second, the talofibular space at the passive neutral position (D1) and maximum varus position (D2) was measured (by stress sonographic images), and the difference (ΔD = D1-D2) between them was determined. Third, the parameters of the two groups were statistically compared. Finally, receiver operating characteristic (ROC) curves and area under the curve (AUC) analyses were performed for parameters with significant differences.
RESULTS: The CLAI group comprised 60 patients, yielding data on 60 ankles, whereas the control group comprised 35 participants, yielding data for 70 ankles. Differences in D1, D2, and ΔD of the talofibular space between the two groups were significant, with ΔD proving to be the best diagnostic indicator (P < 0.001). Its AUC, optimal cutoff value, sensitivity, and specificity were 0.922, 0.11 cm, 73 %, and 94 %, respectively, followed by D2 (0.850, 0.47 cm, 67 %, and 94 %, respectively; P < 0.001) and D1 (0.635, 0.47 cm, 67 %, and 94 %, respectively; P = 0.006).
CONCLUSION: Measurement of talofibular space in stress sonography is a valuable diagnostic indicator for CLAI, especially the ΔD between the neutral and stress position.