二维超声与实时剪切波弹性成像联合评估低强度脉冲超声治疗兔跟腱病疗效
研究将90只新西兰白兔跟腱病模型分为对照、假手术和LIPUS组,在第1、4、7、14、28天用二维超声测量跟腱厚度并用实时剪切波弹性成像(SWE)测量长轴杨氏模量,随后行组织学评估。结果显示SWE值升高而平均厚度和组织学评分降低,LIPUS组第28天分别变化9.5%和80.7%;SWE值与组织学评分相关(r=-0.792,p<0.01),平均厚度三组间无显著差异。作者认为二维超声有助于跟腱病诊断,SWE可无创量化LIPUS治疗期间跟腱硬度变化。
要点
- SWE值与组织学评分相关(r=-0.792,p<0.01),可无创量化跟腱硬度变化。
- LIPUS组第1天SWE值显著低于对照组(121.0 kPa vs. 177.6 kPa),第7天达峰值173.7 kPa(p<0.001)。
- 第28天LIPUS组SWE值接近对照组(191.2 kPa vs. 192.4 kPa),自第7天起显著高于假手术组。
核心结论
- 二维超声有助于跟腱病诊断,SWE可无创量化LIPUS治疗期间跟腱硬度变化,可用于研究LIPUS治疗后早期跟腱愈合。
研究设计与样本
- 动物实验:90只新西兰白兔建立跟腱病模型后分为对照、假手术和LIPUS组,第1、4、7、14、28天行二维超声和实时剪切波弹性成像(SWE)测量长轴杨氏模量,随后行组织学评估。
关键影像表现/征象
- SWE值升高而平均厚度和组织学评分降低,LIPUS组第28天分别变化9.5%和80.7%。
- LIPUS组第1天SWE值显著低于对照组(121.0 kPa vs. 177.6 kPa),第7天达峰值173.7 kPa(p<0.001)。
- 第28天LIPUS组SWE值接近对照组(191.2 kPa vs. 192.4 kPa),自第7天起显著高于假手术组。
- 平均厚度在三组均降低但组间无显著差异。
诊断标准与关键数值
- SWE值与组织学评分相关(r=-0.792,p<0.01)。
- LIPUS组第1天SWE值121.0 kPa显著低于对照组177.6 kPa。
- LIPUS组第7天SWE峰值173.7 kPa(p<0.001)。
- 第28天LIPUS组SWE值191.2 kPa与对照组192.4 kPa接近。
临床应用与阅片要点
- 二维超声可用于跟腱病诊断。
- SWE可无创量化LIPUS治疗期间跟腱硬度变化,有助于研究LIPUS治疗后早期跟腱愈合。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: Low-intensity pulsed ultrasound (LIPUS) has been gradually used to treat Achilles tendinopathy. However, there are limited non-invasive and efficient instruments for monitoring LIPUS efficacy in Achilles tendinopathy. The purpose of this study was to assess the therapeutic effectiveness of LIPUS after Achilles tendinopathy by 2-D ultrasound and real-time shear wave elastography (SWE).
METHODS: Ninety New Zealand white rabbits were divided into control, sham and LIPUS groups after tendinopathy modeling. On days 1, 4, 7, 14 and 28, the Achilles tendon thickness and SWE Young's modulus on the long axis were measured. The tissues of the Achilles tendon were then evaluated histologically.
RESULTS: The mean SWE values increased while the average thickness and histologic scores decreased, especially in the LIPUS group (9.5% and 80.7% on day 28, respectively). The SWE values in the LIPUS group were significantly lower than those in the control group on day 1 (121.0 kPa vs. 177.6 kPa) and peaked on day 7 (173.7 kPa, p < 0.001). By day 28, the SWE value had approached that of the control (191.2 kPa vs. 192.4 kPa), and had been significantly higher than that in the sham group since day 7. SWE values and histologic scores were correlated (r = -0.792, p < 0.01). The average thickness decreased in the three groups but did not differ significantly.
CONCLUSION: Two-dimensional ultrasound is beneficial to the diagnosis of Achilles tendinopathy. SWE could quantify changes in Achilles tendon stiffness non-invasively during LIPUS treatment, enabling the study of early Achilles tendon healing after LIPUS treatment.
引用
- Liu M, Zheng Q, Zheng Y, et al. Combined Assessment of 2-D Ultrasound and Real-Time Shear Wave Elastography of Low-Intensity Pulsed Ultrasound Therapy Efficacy in Rabbits with Achilles Tendinopathy. Ultrasound Med Biol. 2023. PMID: 38129224. doi:10.1016/j.ultrasmedbio.2023.12.001
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。