文献速递骨肌技术与安全MR

磁共振指纹成像多参数定量比较骨转移瘤与红骨髓或脂肪骨髓的T1和T2弛豫时间

Multiparametric quantification of T1 and T2 relaxation time of bone metastasis in comparison with red or fatty bone marrow using magnetic resonance fingerprinting.
PubMed 文献 · Skeletal Radiol · 2023-12-02

回顾性纳入60例接受腰椎和骨盆磁共振指纹成像的患者,测量骨转移瘤、红骨髓和脂肪骨髓的T1和T2值。成骨性转移瘤T1值显著高于红骨髓(1674.6±436.3 vs 858.7±319.5,p<.001),T1和T2观察者间ICC分别为0.96和0.83;成骨性转移瘤与红骨髓的T2值无差异证据(57.9±25.0 vs 58.0±34.4,p=0.45),溶骨性转移瘤与红骨髓平均T2值亦无差异证据(45.3±15.1 vs 58.0±34.4,p=0.63)。

要点

  • 成骨性转移瘤T1值显著高于红骨髓(1674.6±436.3 vs 858.7±319.5,p<.001)
  • T1和T2的观察者间ICC分别为0.96(p<0.001)和0.83(p<0.001)
  • 成骨性转移瘤与红骨髓T2值无差异证据,溶骨性转移瘤与红骨髓平均T2值亦无差异证据

核心结论

  • 三维磁共振指纹成像可同时定量脊柱和骨盆骨转移瘤与红骨髓沉积的T1和T2值,成骨性转移瘤与红骨髓T1值存在显著差异且观察者间一致性极好;三维磁共振指纹成像的T1值可能是评估骨髓病变的有用定量指标。

研究设计与样本

  • 回顾性纳入60例接受腰椎和骨盆磁共振指纹成像的患者,由两名放射科医师独立在三维磁共振指纹成像上测量转移性骨病变、脂肪骨髓和红骨髓沉积的T1和T2值,并进行组间比较和观察者间一致性分析。

诊断标准与关键数值

  • 成骨性转移瘤T1值1674.6±436.3 vs 红骨髓858.7±319.5,p<.001
  • 成骨性转移瘤T2值57.9±25.0 vs 红骨髓58.0±34.4,p=0.45,无差异证据
  • 溶骨性转移瘤平均T2值45.3±15.1 vs 红骨髓58.0±34.4,p=0.63,无差异证据
  • T1值观察者间ICC为0.96(p<0.001),T2值观察者间ICC为0.83(p<0.001)

临床应用与阅片要点

  • 三维磁共振指纹成像可同时定量脊柱和骨盆骨转移瘤与红骨髓沉积的T1和T2值。
  • 成骨性转移瘤T1值显著高于红骨髓,T1值可能是鉴别骨转移瘤与红骨髓的定量指标。
  • T1值观察者间一致性极好(ICC 0.96),T2值一致性良好(ICC 0.83)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To assess the T1 and T2 values of bone marrow lesions in spine and pelvis derived from magnetic resonance fingerprinting (MRF) and to evaluate the differences in values among bone metastasis, red marrow and fatty marrow.

METHODS: Sixty patients who underwent lumbar spine and pelvic MRI with magnetic resonance fingerprinting were retrospectively included. Among eligible patients, those with bone metastasis, benign red marrow deposition and normal fatty marrow were identified. Two radiologists independently measured the T1 and T2 values from metastatic bone lesions, fatty marrow, and red marrow deposition on three-dimensional-magnetic resonance fingerprinting. Intergroup comparison and interobserver agreement were analyzed.

RESULTS: T1 relaxation time was significantly higher in osteoblastic metastasis than in red marrow (1674.6 ± 436.3 vs 858.7 ± 319.5, p < .001). Intraclass correlation coefficients for T1 and T2 values were 0.96 (p < 0.001) and 0.83 (p < 0.001), respectively. T2 relaxation time of osteoblastic metastasis and red marrow deposition had no evidence of a difference (osteoblastic metastasis, 57.9 ± 25.0 vs red marrow, 58.0 ± 34.4, p = 0.45), as were the average T2 values of osteolytic metastasis and red marrow deposition (osteolytic metastasis, 45.3 ± 15.1 vs red marrow, 58.0 ± 34.4, p = 0.63).

CONCLUSIONS: We report the feasibility of three-dimensional-magnetic resonance fingerprinting based quantification of bone marrow to differentiate bone metastasis from red marrow. Simultaneous T1 and T2 quantification of metastasis and red marrow deposition was possible in spine and pelvis and showed significant different values with excellent inter-reader agreement.

ADVANCE IN KNOWLEDGE: T1 values from three-dimensional-magnetic resonance fingerprinting might be a useful quantifier for evaluating bone marrow lesions.

来源:Skeletal Radiol,查看原文。版权归原作者所有。

引用

  1. Byun H, Han D, Chun HJ, et al. Multiparametric quantification of T1 and T2 relaxation time of bone metastasis in comparison with red or fatty bone marrow using magnetic resonance fingerprinting. Skeletal Radiol. 2023. PMID: 38041749. doi:10.1007/s00256-023-04521-2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。