基于深度学习的疑似创伤性肩关节损伤患者CT样MR图像质量增强
前瞻性纳入32例疑似创伤性肩关节损伤患者,比较压缩感知(CS)与深度学习(DL)联合重建的CT样MR图像与常规CS重建图像的诊断性能;CS DL与CS仅图像对骨性病变诊断几乎完全一致(κ 0.95),CS DL在图像质量、骨折线及骨碎片可见性评分和SNR、CNR上均显著更高。
要点
- CS DL重建的CT样MR图像在骨折线、骨碎片及盂缘可见性评分上显著高于CS仅图像(范围3.7-4.9 vs 3.2-3.8,P=0.01-0.04)。
- CS DL与CS仅图像对全部23处急性骨折及骨性病变诊断几乎完全一致(κ 0.95,95%CI 0.82-1.00)。
- CS DL重建的SNR和CNR显著高于CS仅重建(P=0.02-0.03)。
核心结论
- 使用基于DL的算法重建高分辨率CT样MR图像用于评估创伤性肩关节病变是可行的。
研究设计与样本
- 前瞻性纳入32例疑似创伤性肩关节损伤患者(12例女性,平均年龄46±14.9岁),所有患者接受肩关节MR检查,包括CT样3D T1加权梯度回波序列,疑似骨折者加做常规CT;采用结合CS与DL的自动算法(CS DL)对与CS重建相同的k空间数据进行重建;由两名肌骨放射科医师用5点Likert量表评估骨性病变、图像质量和解剖标志可见性,并计算SNR和CNR。
关键影像表现/征象
- 与CT相比,CS仅和CS DL图像均准确检出全部23处急性骨折及骨性病变。
- CS DL重建的骨折线、骨碎片和盂缘可见性评分范围3.7-4.9,CS仅图像范围3.2-3.8,CS DL显著更高(P=0.01-0.04)。
- CS DL重建的SNR和CNR值显著高于CS仅重建(P=0.02-0.03)。
诊断标准与关键数值
- 以CT为参考,CS仅和CS DL图像对急性骨折(n=23)及骨性病变检出准确。
- CS DL与CS仅图像诊断一致性κ为0.95(95%CI 0.82-1.00)。
- 图像质量及解剖标志可见性采用5点Likert量表评分。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate the diagnostic performance of CT-like MR images reconstructed with an algorithm combining compressed sense (CS) with deep learning (DL) in patients with suspected osseous shoulder injury compared to conventional CS-reconstructed images.
METHODS: Thirty-two patients (12 women, mean age 46 ± 14.9 years) with suspected traumatic shoulder injury were prospectively enrolled into the study. All patients received MR imaging of the shoulder, including a CT-like 3D T1-weighted gradient-echo (T1 GRE) sequence and in case of suspected fracture a conventional CT. An automated DL-based algorithm, combining CS and DL (CS DL) was used to reconstruct images of the same k-space data as used for CS reconstructions. Two musculoskeletal radiologists assessed the images for osseous pathologies, image quality and visibility of anatomical landmarks using a 5-point Likert scale. Moreover, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated.
RESULTS: Compared to CT, all acute fractures (n = 23) and osseous pathologies were detected accurately on the CS only and CS DL images with almost perfect agreement between the CS DL and CS only images (κ 0.95 (95 %confidence interval 0.82-1.00). Image quality as well as the visibility of the fracture lines, bone fragments and glenoid borders were overall rated significantly higher for the CS DL reconstructions than the CS only images (CS DL range 3.7-4.9 and CS only range 3.2-3.8, P = 0.01-0.04). Significantly higher SNR and CNR values were observed for the CS DL reconstructions (P = 0.02-0.03).
CONCLUSION: Evaluation of traumatic shoulder pathologies is feasible using a DL-based algorithm for reconstruction of high-resolution CT-like MR imaging.
引用
- Feuerriegel GC, Weiss K, Tu Van A, et al. Deep-learning-based image quality enhancement of CT-like MR imaging in patients with suspected traumatic shoulder injury. Eur J Radiol. 2023. PMID: 38056345. doi:10.1016/j.ejrad.2023.111246
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。