文献速递骨肌MRCT

常规MR关节造影与三维容积MR关节造影在检测肩胛盂唇病理伴随的软骨缺损中的比较

Comparison of conventional MR arthrography and 3D volumetric MR arthrography in detection of cartilage defects accompanying glenoid labrum pathologies.
PubMed 文献 · Skeletal Radiol · 2023-12-05

研究纳入79例临床 prediagnosed 盂唇病理的患者,于2021年12月至2022年5月行MRA与CTA,以CTA为参考标准。常规MRA两位阅片者敏感度17-19%、特异度100%、准确率49-51%;T1加权容积MRA敏感度67-65%、特异度92-97%、准确率84-77%。T1加权容积MRA似乎能准确显示盂唇病理伴随的软骨缺损,敏感度和特异度高,阅片者间一致性极好。

要点

  • T1加权容积MRA对盂唇病理伴随软骨缺损的敏感度67-65%,常规MRA仅17-19%。
  • 常规MRA特异度100%,T1加权容积MRA特异度92-97%。
  • 所有MRA诊断软骨缺损的阅片者间一致性均为极好。

核心结论

  • T1加权容积MRA似乎能准确显示盂唇病理伴随的软骨缺损,具有高敏感度、高特异度和极好的阅片者间一致性。

研究设计与样本

  • 共纳入79例基于肩部MRI prediagnosed 盂唇病理的患者,于2021年12月至2022年5月行MRA和CTA,以CTA为参考标准;CTA由一位骨肌影像经验丰富的放射科医生阅片,MRA由两位放射科医生独立阅片。

诊断标准与关键数值

  • 常规MRA两位阅片者检测软骨缺损的敏感度17-19%、特异度100%、准确率49-51%。
  • T1加权容积MRA两位阅片者检测软骨缺损的敏感度67-65%、特异度92-97%、准确率84-77%。
  • MRA检测肩胛盂软骨病变的总体敏感度69%、特异度97%、准确率80%。
  • 79例盂唇病理患者中48例(60.75%)在CTA上检出软骨缺损。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: In this study, we aimed to compare conventional and T1-weighted volumetric magnetic resonance arthrography (MRA) in the diagnosis and grading of glenoid cartilage defects that accompany labral pathologies.

MATERIALS AND METHODS: A total of 79 patients who were prediagnosed with labrum pathologies based on shoulder magnetic resonance imaging (MRI) had MRA and CTA between December 2021 and May 2022. CTA was regarded as reference standard. CTA images were examined by a radiologist experienced in musculoskeletal radiology, and MRA images were examined by two radiologists independently to determine presence, grade, and localization of any glenoid cartilage defect, if present. Sensitivity, specificity, and accuracy were calculated separately for conventional and T1-weighted volumetric MRA. In addition, at the last stage, two observers examined all MRAs together, and the presence of a cartilage defect was decided by consensus, and the overall sensitivity, specificity, and accuracy were calculated.

RESULTS: Cartilage defect was detected on CTAs of 48 (60.75%) cases of among 79 patients with labrum pathology. The sensitivity, specificity, and accuracy of conventional MRA for two examiners were 17-19%, 100-100%, and 49-51%, respectively, while those values were 67-65%, 92-97%, and 84-77%, respectively, for T1-weighted volumetric MRA. Inter-examiner agreement was excellent for diagnosis of cartilage defects on all MRAs. The overall sensitivity, specificity, and accuracy for detection of glenoid cartilage lesions by MRA were 69%, 97%, and 80%, respectively.

CONCLUSION: T1-weighted volumetric MRA seems to demonstrate cartilage defects accompanied with labrum pathologies accurately with high sensitivity, specificity, and excellent inter-examiner agreement.

来源:Skeletal Radiol,查看原文。版权归原作者所有。

引用

  1. Gokce A, Guclu D, Unlu EN, et al. Comparison of conventional MR arthrography and 3D volumetric MR arthrography in detection of cartilage defects accompanying glenoid labrum pathologies. Skeletal Radiol. 2023. PMID: 38051423. doi:10.1007/s00256-023-04536-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。