文献速递骨肌US

肩袖超声扫查人工智能辅助系统的开发与临床应用

Development and Clinical Application of Artificial Intelligence Assistant System for Rotator Cuff Ultrasound Scanning.
PubMed 文献 · Ultrasound Med Biol · 2023-12-01

研究开发了基于ResNet50标准切面识别模块与Mask R-CNN自动组织分割模块的肩关节超声智能辅助系统,用59,265张肩关节超声图像训练,测试集标准切面识别准确率94.9%,1886张图像上自动分割平均交并比96.2%,各标准切面平均交并比均超过90.0%。

要点

  • 标准切面识别模型测试集准确率94.9%,平均精确率96.4%、召回率95.4%、F1值95.9%。
  • 自动组织分割模型在1886张图像上平均交并比96.2%,各标准切面均超过90.0%。
  • 系统可快速准确识别标准切面并自动分割肩袖及周围结构。

核心结论

  • 肩关节肌肉骨骼智能系统能快速准确地识别标准切面并完成自动组织分割。

研究设计与样本

  • 开发并评估肩关节超声智能辅助系统,标准切面识别模块基于ResNet50网络,自动组织分割模块采用Mask R-CNN模型,使用59,265张肩关节超声图像训练。

诊断标准与关键数值

  • 标准切面识别模型在测试集准确率94.9%,平均精确率96.4%,召回率95.4%,F1值95.9%。
  • 自动组织分割模型在1886张图像上平均交并比96.2%,所有标准切面平均交并比均超过90.0%。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: We developed an intelligent assistance system for shoulder ultrasound imaging, incorporating deep-learning algorithms to facilitate standard plane recognition and automatic tissue segmentation of the rotator cuff and its surrounding structures. We evaluated the system's performance using a dedicated data set of rotator cuff ultrasound images to assess its feasibility in clinical practice.

METHODS: To fulfill the system's primary functions, we designed a standard plane recognition module based on the ResNet50 network and an automatic tissue segmentation module using the Mask R-CNN model. The modules were trained on carefully curated data sets. The standard plane recognition module automatically identifies a specific standard plane based on the ultrasound image characteristics. The automatic tissue segmentation module effectively delineates and segments anatomical structures within the identified standard plane.

RESULTS: With the use of 59,265 shoulder joint ultrasound images, the standard plane recognition model achieved an impressive recognition accuracy of 94.9% in the test set, with an average precision rate of 96.4%, recall rate of 95.4% and F1 score of 95.9%. The automatic tissue segmentation model, tested on 1886 images, exhibited a commendable average intersection over union value of 96.2%, indicating robustness and accuracy. The model achieved mean intersection over union values exceeding 90.0% for all standard planes, indicating its effectiveness in precisely delineating the anatomical structures.

CONCLUSION: Our shoulder joint musculoskeletal intelligence system swiftly and accurately identifies standard planes and performs automatic tissue segmentation.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Tang R, Li Z, Jiang L, et al. Development and Clinical Application of Artificial Intelligence Assistant System for Rotator Cuff Ultrasound Scanning. Ultrasound Med Biol. 2023. PMID: 38042717. doi:10.1016/j.ultrasmedbio.2023.10.010

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。