文献速递骨肌MR

MRI诊断肱二头肌长头腱撕裂的诊断效能:系统评价与Meta分析

Diagnostic performance of long head of biceps tendon tears on MRI: systematic review and meta-analysis.
PubMed 文献 · Eur Radiol · 2023-12-27

该系统评价与Meta分析以关节镜为参考标准,评估常规MRI和MR关节造影对肱二头肌长头腱完全撕裂、部分撕裂及肌腱变性的诊断效能。完全撕裂汇总阳性似然比37.3(95%CI 11.9-117.4),特异度高但敏感度异质性大;部分撕裂/肌腱变性平均敏感度67.8%、特异度75.9%,诊断仍具挑战性。

要点

  • MRI对肱二头肌长头腱完全撕裂特异度高(93.0-99.0%),但敏感度异质性大(55.9-90.0%)。
  • 部分撕裂/肌腱变性平均敏感度67.8%、特异度75.9%,平衡准确率71.9%。
  • 部分撕裂/肌腱变性诊断困难时,原文认为可能需要结合临床检查或其他影像方式。

核心结论

  • MRI诊断肱二头肌长头腱完全撕裂特异度高,敏感度异质性较大;部分撕裂和/或肌腱变性在MRI上诊断仍具挑战性。

研究设计与样本

  • 系统评价与Meta分析,检索PubMed 2000年1月至2022年4月发表的文献并回顾性汇总分析,以关节镜为参考标准。

诊断标准与关键数值

  • 完全撕裂纳入6项MRI研究(n=555),MRI特异度93.0-99.0%、敏感度55.9-90.0%,汇总阴性似然比0.29(95%CI 0.17-0.50)、阳性似然比37.3(95%CI 11.9-117.4)。部分撕裂/肌腱变性纳入10项研究(n=2487),平均敏感度67.8%(95%CI 54.3-78.9%)、特异度75.9%(95%CI 63.6-85.0%)、平衡准确率71.9%,汇总阴性似然比0.44(95%CI 0.32-0.59)、阳性似然比2.64(95%CI 1.91-3.65)。

临床应用与阅片要点

  • 原文指出部分撕裂和/或肌腱变性诊断困难时,可能需要结合临床检查或其他影像方式以提高诊断信心。

局限性

  • 原文指出部分撕裂和/或肌腱变性在MRI上诊断仍具挑战性。
  • 原文认为部分撕裂/肌腱变性诊断困难时可能需要结合临床检查或其他影像方式以提高诊断信心,提示现行MRI诊断信心有限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The purpose of this meta-analysis was to determine the diagnostic performance of conventional MRI and MR arthrography for tendinosis, and partial and complete tears of the long head of the biceps tendon (LHBT) using arthroscopy as the reference standard.

MATERIALS AND METHODS: A systematic review was performed using predefined data fields in PubMed, and all articles published from January 2000 up to April 2022 were retrospectively pooled and reviewed. Six MRI studies on complete tear (n = 555) and ten studies on partial tear/tendinosis (n = 2487) were included in the analysis. Two of the included studies in each group investigated the use of MR arthrography. The data sets were analyzed using a univariate approach with the DerSimonian and Laird random effects model and the proportional hazards model.

RESULTS: MRI shows high specificities in diagnosing complete tears of the LHBT ranging from 93.0 to 99.0%. Diagnostic sensitivity was more heterogeneous ranging from 55.9 to 90.0%. The overall negative likelihood ratio was 0.29 (95% CI: 0.17-0.50) and the overall positive likelihood ratio was 37.3 (95% CI: 11.9-117.4). The mean sensitivity in diagnosing partial tear/tendinosis of the LHBT was 67.8% (95% CI: 54.3-78.9%) and the specificity was 75.9% (95% CI: 63.6-85.0%), resulting in a balanced accuracy of 71.9%. The overall negative likelihood ratio was 0.44 (95% CI: 0.32-0.59) and the overall positive likelihood ratio was 2.64 (95% CI: 1.91-3.65).

CONCLUSION: MRI is highly specific for the diagnosis of complete tears of the LHBT, whereas diagnostic sensitivity was more heterogeneous. The diagnosis of partial tears and/or tendinosis of the LHBT remains challenging on MRI, which may warrant complementary clinical examination or other imaging modalities to increase diagnostic confidence in equivocal cases.

CLINICAL RELEVANCE STATEMENT: Conventional MRI and MR arthrography have high diagnostic performance for complete tendon tear when compared to arthroscopy. The diagnosis of tendinosis/partial tears remains challenging and may require comparison with clinical tests and other imaging modalities.

KEY POINTS: •There is no clear consensus regarding the primary imaging modality for the evaluation of LHBT disorders. •Conventional MRI and MR arthrography are highly specific in diagnosing complete tears of the LHBT. •Diagnosis of partial tears/tendinosis of the LHBT on conventional MRI and MR arthrography remains a diagnostic challenge.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Almeida GG, Graf N, Wildermuth S, et al. Diagnostic performance of long head of biceps tendon tears on MRI: systematic review and meta-analysis. Eur Radiol. 2023. PMID: 38148406. doi:10.1007/s00330-023-10521-6

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。