文献速递乳腺MR

同步多层技术加速读出分段平面回波成像用于乳腺扩散加权MRI:图像质量因素评估

Accelerating acquisition of readout-segmented echo planar imaging (rs-EPI) with a simultaneous multislice (SMS) technique for diffusion-weighted (DW) breast MRI: Evaluation of image quality factors.
PubMed 文献 · Eur J Radiol · 2023-12-06

纳入80例连续接受乳腺扩散加权成像的女性,比较rs-EPI与SMS rs-EPI序列的图像质量、ADC值、SNR、CNR及扫描时间。SMS rs-EPI扫描时间较rs-EPI缩短42%,图像质量评分总体相似(皮肤线区分与背景噪声除外),体模测量ADC、SNR、CNR无显著差异,但临床患者ADC值SMS rs-EPI显著高于rs-EPI。

要点

  • SMS rs-EPI扫描时间3分20秒,较rs-EPI的5分47秒缩短42%。
  • 临床患者ADC值SMS rs-EPI显著高于rs-EPI(所有放射科医师测量均p≤0.002)。
  • 体模测量ADC、SNR、CNR两序列无显著差异。

核心结论

  • SMS rs-EPI图像质量与rs-EPI相当,ADC、SNR、CNR值相似,同时扫描时间缩短42%。

研究设计与样本

  • 连续纳入80例接受乳腺扩散加权成像的女性,采集rs-EPI与SMS rs-EPI两种DWI序列进行对比;由三名放射科医师独立评分图像质量和偏好,并独立测量患者ADC值;体模上测量SNR、CNR和ADC值。

关键影像表现/征象

  • 合并数据集图像质量评分除皮肤线区分(p=0.001)和背景噪声(p<0.001)外,rs-EPI与SMS rs-EPI相似。
  • 所有放射科医师认为SMS rs-EPI在超过70%的病例中等于或优于rs-EPI。

诊断标准与关键数值

  • 临床患者ADC值:SMS rs-EPI显著高于rs-EPI(所有放射科医师测量均p≤0.002)。
  • 体模ADC值:SMS 1.26±0.68 vs RS 1.26±0.68,p=0.198,无显著差异。
  • 体模SNR:SMS 540.6±342.1 vs RS 558.8±523.2,p=0.927,无显著差异。
  • 体模CNR:SMS 235.5±38.9 vs RS 252.8±108.0,p=0.784,无显著差异。
  • 采集时间:rs-EPI 5分47秒 vs SMS rs-EPI 3分20秒,SMS rs-EPI缩短42%。

临床应用与阅片要点

  • SMS rs-EPI可在保持图像质量与体模ADC、SNR、CNR相似的前提下将乳腺DWI扫描时间从5分47秒缩短至3分20秒。
  • 临床患者ADC值SMS rs-EPI显著高于rs-EPI,阅片及ADC阈值应用时需注意序列间差异。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: This study aims to compare the image quality, apparent diffusion coefficient (ADC), signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) values, and scan time between readout-segmented echo planar imaging (rs-EPI) and simultaneous multislice (SMS) rs-EPI sequences.

METHODS: A total of 80 consecutive women who underwent breast diffusion-weighted imaging (DWI) were included, and two rs-EPI DWI sequences with and without SMS were acquired and compared. Qualitative analysis involved three radiologists independently scoring image quality and radiologist preference. For quantitative comparison, the radiologists independently measured the ADC values in patients, while SNR, CNR, and ADC values were measured on a phantom.

RESULTS: The acquisition time was 5:47 min for rs-EPI and 3:20 min for SMS rs-EPI. In terms of image quality, scores were similar between rs-EPI and SMS rs-EPI sequences in the pooled data set, with the exception of skin-line distinction (p = 0.001) and background noise (p < 0.001). All radiologists considered SMS rs-EPI as equal or superior to rs-EPI in more than 70 % of cases. SMS rs-EPI demonstrated significantly higher ADC values than rs-EPI by all radiologists (p ≤ 0.002). For the phantom measurement, ADC (SMS: 1.26 ± 0.68 and RS: 1.26 ± 0.68, p = 0.198), SNR (SMS: 540.6 ± 342.1 and RS: 558.8 ± 523.2, p = 0.927), and CNR (SMS: 235.5 ± 38.9 and RS: 252.8 ± 108.0, p = 0.784) values did not significantly differ between the two sequences.

CONCLUSION: SMS rs-EPI exhibited comparable image quality and similar ADC, SNR, and CNR values to rs-EPI while reducing the scan time by 42%.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Ahn HS, Kim SH, Kim JY, et al. Accelerating acquisition of readout-segmented echo planar imaging (rs-EPI) with a simultaneous multislice (SMS) technique for diffusion-weighted (DW) breast MRI: Evaluation of image quality factors. Eur J Radiol. 2023. PMID: 38128255. doi:10.1016/j.ejrad.2023.111251

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。