人工智能软件在临床乳腺学中的作用:一项乳腺X线摄影多阅片者研究
该研究回顾性分析210例有完整临床和影像记录的患者,以病理或1年随访为参考标准,由4名不同经验阅片者(1名初级和3名资深乳腺放射科医生)用5点Likert量表评估乳腺X线摄影和断层合成图像,比较AI软件独立诊断及辅助阅片者的诊断效能。AI独立准确率71%(敏感度69%、特异度73%),总体低于无AI辅助的阅片者;但AI辅助下,经验较少的放射科医生和一名资深放射科医生的准确率(P=0.004)和特异度(P=0.04)显著提高。
要点
- AI独立诊断准确率71%(敏感度69%、特异度73%),总体低于无AI辅助的阅片者。
- AI辅助使经验较少的放射科医生和一名资深放射科医生的准确率(P=0.004)和特异度(P=0.04)显著提高。
- 作者认为AI作为第二阅片者可能提高敏感度和特异度,尤其对经验较少的放射科医生。
核心结论
- AI软件作为乳腺病变评估的第二阅片者,可能通过提高敏感度和特异度在临床中发挥关键作用,尤其对经验较少的放射科医生。
研究设计与样本
- 回顾性分析210例有完整临床和影像记录的患者,以病理(手术或活检患者)或1年随访(其余患者)为参考标准;4名不同经验阅片者(1名初级和3名资深乳腺放射科医生)用5点Likert量表评估乳腺X线摄影和断层合成图像;采用多阅片者多病例分析,P<0.05为统计学显著。
诊断标准与关键数值
- AI系统独立诊断准确率71%(敏感度69%、特异度73%),总体低于无AI辅助的阅片者;AI辅助下经验较少的放射科医生和一名资深放射科医生的准确率(P=0.004)和特异度(P=0.04)显著提高。
临床应用与阅片要点
- 作者认为AI软件作为乳腺病变评估的第二阅片者,可能通过提高敏感度和特异度在临床中发挥关键作用,尤其对经验较少的放射科医生。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate the diagnostic role of a dedicated AI software in detecting anomalous breast findings on mammography and tomosynthesis images in the clinical setting, stand-alone and as aid of four readers.
METHODS: A total of 210 patients with complete clinical and radiologic records were retrospectively analyzed. Pathology was used as the reference standard for patients undergoing surgery or biopsy, and a 1-year follow-up was used to confirm no change in the remaining patients. The image evaluation was performed by four readers with different levels of experience (a junior and three senior breast radiologists) using a 5-point Likert scale moving from 1 (definitively no cancer) to 5 (definitively cancer). The positivity of mammograms was assessed on the presence of any breast lesion (masses, architectural distortions, asymmetries, calcifications), including malignant and benign ones. A multi-reader multi-case analysis was performed. A p value < 0.05 was considered statistically significant.
RESULTS: The stand-alone AI system achieved an accuracy of 71% (69% sensitivity and 73% specificity), which is overall lower than the value achieved by readers without AI. However, with the aid of AI, a significant increase of accuracy (p value = 0.004) and specificity (p value = 0.04) was achieved for the less experienced radiologist and a senior one.
CONCLUSION: The use of AI software as a second reader for breast lesions assessment could play a crucial role in the clinical setting, by increasing sensitivity and specificity, especially for less experienced radiologists.
引用
- Bassi E, Russo A, Oliboni E, et al. The role of an artificial intelligence software in clinical senology: a mammography multi-reader study. Radiol Med. 2023. PMID: 38082194. doi:10.1007/s11547-023-01751-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。