基于动态增强MRI的Delta影像组学预测浸润性乳腺癌淋巴血管侵犯
本研究纳入293例可切除浸润性乳腺癌患者,术前行动态增强MRI,提取增强前(A0)、首次增强后(A1)及减影图像的影像组学特征,构建Radiomics-A0、Radiomics-A1和Radiomics-Delta模型,并联合影像学特征建立混合模型预测淋巴血管侵犯。测试集中Radiomics-Delta的AUC为0.781,优于Radiomics-A0的0.619和Radiomics-A1的0.715;混合模型表现最佳,AUC为0.868,准确率为0.875。
要点
- Radiomics-Delta模型在测试集AUC为0.781,优于Radiomics-A0的0.619和Radiomics-A1的0.715。
- 混合模型整合Radiomics-Delta与影像学特征,测试集AUC为0.868,准确率为0.875。
- 混合模型性能优于影像学模型(AUC 0.759)和Radiomics-Delta模型(AUC 0.781)。
核心结论
- Radiomics-Delta表现优于Radiomics-A0和Radiomics-A1;整合Radiomics-Delta与影像学特征的混合模型在判断浸润性乳腺癌淋巴血管侵犯状态方面表现出色。
研究设计与样本
- 共纳入293例可切除浸润性乳腺癌患者,术前行DCE-MRI,从增强前(A0)、首次增强后(A1)及A0与A1的减影图像中提取影像组学特征,构建三个影像组学模型,并通过逻辑分析筛选影像学特征预测LVI状态,建立混合模型,采用ROC曲线下面积(AUC)评估模型性能。
诊断标准与关键数值
- 测试集中Radiomics-Delta模型(17个影像组学特征)AUC为0.781,准确率为0.705;Radiomics-A0模型(10个特征)AUC为0.619,准确率为0.523;Radiomics-A1模型(8个特征)AUC为0.715,准确率为0.591;混合模型AUC为0.868,准确率为0.875;影像学模型AUC为0.759,准确率为0.773。
临床应用与阅片要点
- 作者认为,整合Radiomics-Delta与影像学特征的混合模型在判断浸润性乳腺癌淋巴血管侵犯状态方面表现出色。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: Treatment strategies for invasive breast cancer require accurate lymphovascular invasion (LVI) predictions. This study aimed to investigate the effectiveness of delta radiomics based on dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) for assessing LVI and develop a nomogram to aid treatment decisions.
MATERIALS AND METHODS: Overall, 293 patients with resectable invasive breast cancer underwent preoperative DCE-MRI. Radiomic features were extracted from pre-contrast (A0), first post-contrast (A1), and subtracted images of A0 and A1. Three radiomics models were developed using several data analyses; logistic analyses were performed to identify radiological features to predict the LVI status. A hybrid model integrating both radiological features and optimal radiomics was developed. Receiver operating characteristic analysis was employed to evaluate model performance, using the area under the curve (AUC) as a quantitative metric for discriminative ability.
RESULTS: In the test set, the Radiomics-Delta model, with 17 radiomic features, had an AUC of 0.781 and accuracy of 0.705. Radiomics-A0, with 10 features, had an AUC of 0.619 and accuracy of 0.523, while Radiomics-A1, with 8 features, had an AUC of 0.715 and accuracy of 0.591. The hybrid model exhibited better performance, with an AUC of 0.868 and accuracy of 0.875, than the radiological and Radiomics-Delta models, with an AUC of 0.759 and 0.781, respectively, and accuracy of 0.773 and 0.705, respectively.
CONCLUSION: Compared to Radiomics-A0 and Radiomics-A1, Radiomics-Delta demonstrated superior performance. Moreover, the hybrid model incorporating Radiomics-Delta and radiological features exhibited excellent performance in determining the LVI status in cases of invasive breast cancer.
引用
- Zheng H, Jian L, Li L, et al. Delta-Radiomics Based on Dynamic Contrast-Enhanced MRI for Predicting Lymphovascular Invasion in Invasive Breast Cancer. Acad Radiol. 2023. PMID: 38092588. doi:10.1016/j.acra.2023.11.017
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。