评价子宫肌瘤血供:对比增强超声与对比增强磁共振成像的比较
本研究纳入40例有症状的子宫肌瘤患者,在子宫动脉栓塞术前用对比增强超声(CEUS)评估肌瘤血供,并以对比增强MRI为参考标准。38例完成两种检查,CEUS与MRI对血供分类一致36例,准确率95%(p=0.62)。作者认为CEUS能准确评估子宫肌瘤血供,可能作为MRI的潜在替代方法。
要点
- CEUS以增强MRI为参考标准评估子宫肌瘤血供,38例中36例分类一致,准确率95%。
- MRI判为乏血供的2例肌瘤,CEUS判为富血供,为不一致的主要来源。
- 作者认为CEUS可能作为确定子宫肌瘤血供时MRI的潜在替代方法。
核心结论
- 对比增强超声能准确评估子宫肌瘤血供,可能作为确定子宫肌瘤血供时MRI的潜在替代方法。
研究设计与样本
- 经机构审查委员会批准的研究,纳入40例诊断为有症状子宫肌瘤并计划行子宫动脉栓塞术的女性;术前用Aplio i800扫描仪(Canon Medical Systems,Tustin,CA,USA)及凸阵探头(8C1)行CEUS,静脉注射2.0 mL超声造影剂Lumason(Bracco,Milan,Italy);CEUS数字剪辑随机化后离线判读,肌瘤分为富血供或乏血供;以MRI作为肌瘤血供的参考标准并与CEUS比较,采用McNemar检验分析。
诊断标准与关键数值
- 以MRI为参考标准,将肌瘤血供二分类为富血供或乏血供;38例中CEUS与MRI一致36例,准确率95%(p=0.62);MRI显示富血供24例、乏血供14例,CEUS显示富血供26例、乏血供12例。
临床应用与阅片要点
- 判读CEUS时按富血供或乏血供对肌瘤血供进行二分类,并与增强MRI结果对照;注意本研究中MRI判为乏血供的2例被CEUS判为富血供。
局限性
- 1例患者未行子宫动脉栓塞术,1例患者因幽闭恐惧症拒绝术前MRI,最终38例完成CEUS和MRI检查。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: The aim of the work described here was to assess uterine fibroid vascularity using contrast-enhanced ultrasound (CEUS) as compared with magnetic resonance imaging (MRI).
METHODS: Forty women diagnosed with symptomatic uterine fibroids scheduled for uterine artery embolization (UAE) were enrolled in this institutional review board-approved study. Before UAE, participants underwent CEUS examination with an Aplio i800 scanner (Canon Medical Systems, Tustin, CA, USA) with curvilinear array (8C1). CEUS was performed using 2.0 mL of the ultrasound contrast agent Lumason (Bracco, Milan, Italy) administered intravenously. Digital CEUS clips were acquired and randomized offline, and fibroids were characterized as hyper- or hypovascular. MRI was used as reference standard for fibroid vascularity and compared with CEUS. Results were analyzed using McNemar's test.
RESULTS: Forty participants were enrolled in the trial. One patient did not proceed with the UAE procedure and one patient refused pre-procedure MRI because of claustrophobia. Therefore, 38 participants underwent CEUS and MRI examinations before UAE. Hypervascular fibroids were seen on MRI and CEUS in 24 and 26 participants, respectively. Hypovascular fibroids were seen with MRI and CEUS in 14 and 12 participants, respectively. Fibroids characterized as hypovascular in two participants by MRI were characterized as hypervascular by CEUS. CEUS and MRI findings were similar in 36 of 38 participants, corresponding to an accuracy of 95% (p = 0.62).
CONCLUSION: Contrast-enhanced ultrasound can accurately assess uterine fibroid vascularity, serving as a potential alternative to MRI in determination of the vascularity of uterine fibroids.
引用
- Machado P, Tan A, Forsberg F, et al. Evaluation of Uterine Fibroid Vascularity Using Contrast-Enhanced Ultrasound in Comparison with Contrast-Enhanced Magnetic Resonance Imaging. Ultrasound Med Biol. 2023. PMID: 38123378. doi:10.1016/j.ultrasmedbio.2023.11.012
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。