文献速递泌尿生殖腹部CT

双层探测器双能CT在不同体型患者中表征尿路结石的诊断效能与可行性

Diagnostic performance and feasibility of dual-layer detector dual-energy CT for characterization of urinary stones in patients of different sizes.
PubMed 文献 · Abdom Radiol (NY) · 2023-12-02

该回顾性研究评估双层探测器双能CT(dlDECT)在不同体重患者中表征尿路结石的效能,以晶体学为参考标准,视觉区分尿酸与非尿酸结石的敏感度为80%、特异度为98%,Zeff阈值7.66可准确区分(AUC=1.00),不同体重患者结石可表征性相似且图像质量可接受。

要点

  • 彩色叠加Zeff图像可主观判读所有≥3 mm结石(n=491)的成分。
  • 视觉区分尿酸与非尿酸结石敏感度80%(95%CI 44-98%)、特异度98%(95%CI 92-100%)。
  • Zeff阈值7.66区分尿酸与非尿酸结石AUC=1.00。

核心结论

  • dlDECT能在不同体型患者中准确区分尿酸与非尿酸结石,图像质量可接受。

研究设计与样本

  • 回顾性评估2018年7月至2019年11月所有连续dlDECT结石方案检查,155名成人(平均年龄57±15岁,80名男性,中位体重82.6 kg,范围42.6-186.9 kg)的177次CT检查共739枚结石(中位大小3.7 mm,范围1-35 mm),以晶体学为参考标准。

关键影像表现/征象

  • 彩色叠加Zeff图像上可主观判读所有≥3 mm结石(n=491)的成分。
  • 体重>90 kg组86%结石可表征,≤90 kg组87%可表征,两组相似(p=0.20)。
  • 所有不同体重患者的检查图像质量均可接受。

诊断标准与关键数值

  • 视觉区分尿酸与非尿酸结石(有参考标准者n=74):敏感度80%(95%CI 44-98%),特异度98%(95%CI 92-100%)。
  • Zeff阈值7.66区分尿酸与非尿酸结石:AUC=1.00。
  • Zeff分析区分钙基结石与其他非尿酸结石:AUC=0.78;区分所有结石类型:AUC=0.91。

临床应用与阅片要点

  • 彩色叠加Zeff图像可用于主观判读≥3 mm结石成分。
  • Zeff阈值7.66可准确区分尿酸与非尿酸结石。
  • 不同体重患者均可获得可接受的图像质量,体重>90 kg与≤90 kg患者结石可表征性相似。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Urinary stones are frequently encountered in urology and are typically identified using non-contrast CT scans. Dual-energy CT (DECT) is a valuable imaging technique that produces material-specific images and allows for precise assessment of stone composition by estimating the effective atomic number (Zeff), a capability not achievable with the conventional single-energy CT's attenuation measurement method.

PURPOSE: To investigate the diagnostic performance and image quality of dual-layer detector DECT (dlDECT) in characterizing urinary stones in patients of different sizes.

METHODS: All consecutive dlDECT examinations with stone protocol and presence of urinary stones between July 2018 and November 2019 were retrospectively evaluated. Two radiologists independently reviewed 120 kVp and color-overlay Zeff images to determine stone composition (reference standard = crystallography) and image quality. The objective analysis included image noise and Zeff values measurement.

RESULTS: A total of 739 urinary stones (median size 3.7 mm, range 1-35 mm) were identified on 177 CT examinations from 155 adults (mean age, 57 ± 15 years, 80 men, median weight 82.6 kg, range 42.6-186.9 kg). Using color-overlay Zeff images, the radiologists could subjectively interpret the composition in all stones ≥ 3 mm (n = 491). For stones with available reference standards (n = 74), dlDECT yielded a sensitivity of 80% (95%CI 44-98%) and a specificity of 98% (95%CI 92-100%) in visually discriminating uric acid from non-uric acid stones. Patients weighing > 90 kg and ≤ 90 kg had similar stone characterizability (p = 0.20), with 86% of stones characterized in the > 90 kg group and 87% in the ≤ 90 kg group. All examinations throughout various patients' weights revealed acceptable image quality. A Zeff cutoff of 7.66 accurately distinguished uric acid from non-uric acid stones (AUC = 1.00). Zeff analysis revealed AUCs of 0.78 and 0.91 for differentiating calcium-based stones from other non-uric stones and all stone types, respectively.

CONCLUSION: dlDECT allowed accurate differentiation of uric acid and non-uric acid stones among patients with different body sizes with acceptable image quality.

CLINICAL IMPACT: The ability to accurately differentiate uric acid stones from non-uric acid stones using color-overlay Zeff images allows for better tailored treatment strategies, helping to choose appropriate interventions and prevent potential complications related to urinary stones in patient care.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Pisuchpen N, Parakh A, Cao J, et al. Diagnostic performance and feasibility of dual-layer detector dual-energy CT for characterization of urinary stones in patients of different sizes. Abdom Radiol (NY). 2023. PMID: 38041709. doi:10.1007/s00261-023-04116-4